| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Jan 16, 2024 | 37026711M | RESOLVE | CLASS - 2 | FAILURE TO FILE ACCEPTABLE AMENDED CYCLE 9A REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL FA... | $625 | $0 | Sep 30, 2024 |
| Jun 25, 2018 | 38263877H | RESOLVE | CLASS - 2 | 97R5 ILLEGAL REMOVAL OF SIDEWALK ELEVATOR #151591 FILE APPLICATION AND OBTAIN PERMIT FOR REMOVAL OF THE DEVICE. | $0 | $0 | Aug 9, 2018 |
| Feb 15, 2018 | 37006762Y | RESOLVE | CLASS - 1 | BC3307.6.4:DEFICIENT DESIGN-THE RESPONDENT,DESIGN APPLICANT,FAILED TO MEET THE REQS OF BC3307.6.4 AND BC1604.2 IN A H... | $0 | $0 | Dec 27, 2018 |
| Dec 8, 2017 | 35295788N | RESOLVE | CLASS - 2 | WORK DOES NOT CONFORM TO APPROVED PLAN. NOTE: AT TIME OF INSPECTION I OBSERVED SIDEWALK SHED IN PLACE NOT BUILT ACCOR... | $0 | $0 | Jan 25, 2018 |
| Sep 13, 2017 | 35264504K | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE AND APPURTENANCES.NOTE:DAMAGE METAL CLADDING/WOOD ABOVE BULKHEAD.WATER T... | $250 | $0 | Nov 2, 2017 |
| Sep 11, 2013 | 35033653X | RESOLVE | CLASS - 2 | WORK W/O A PERMIT. ILLEGAL WORK NOTED: ON 6TH FLOOR ROOM #603 REMOVAL OF FULL HEIGHT PARTITION W/O FIRST OBTAINING DO... | $0 | $0 | Oct 31, 2013 |
| Sep 11, 2013 | 35033650K | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER.NOTED: 1-NOT SELF CLOSING FIRE EXIT DOORS TO STAIRCASE"A" & P... | $1,000 | $0 | Oct 31, 2013 |
| Sep 11, 2013 | 35033651M | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER: NO FIRE STOPPING PER BC712.3; 27-345 IN BOILER ROOM. RMDY: PRO... | $1,000 | $0 | Oct 31, 2013 |
| Sep 11, 2013 | 35033652Y | RESOLVE | CLASS - 1 | UNSAFE STORAGE OF COMBUSTIBLE MATERIALS AND EQUIPMENT NOTED HAVING STORAGE OF 2 PROPANE GAS TAKS 20 POUNDS EACH ON 5T... | $2,400 | $0 | Oct 31, 2013 |
| Sep 11, 2013 | 35033654H | RESOLVE | CLASS - 1 | FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGWAY. NOTED: 1-ON 10TH FLOORFIRE EXIT DOORS TO STAIRCASE"D" AND FIRE TOWER ... | $1,200 | $0 | Oct 31, 2013 |
| Jun 25, 2008 | 38186006X | RESOLVE | Hazardous | 41N09.55Q07.58B07.60M07.86M05.85M05.84B07.21M07.66O02.38O2. 41N REMOVEJUMPER FROM FUSE 55Q PROVIDE GUARD ON MACHINE A... | $0 | $0 | Aug 14, 2008 |
| Jun 25, 2008 | 38186005Y | RESOLVE | Hazardous | 02X10.33P16.38P16.55Y13.86M05.85M05. REPAIR PHONE SYSTEM IN CAR 33P PROVIDE ACCESS TO HOISTWAY 38P PROVIDE ACCESS TO ... | $0 | $0 | Aug 14, 2008 |
| Jun 23, 2008 | 38185824N | RESOLVE | Non-Hazardous | 55Y13.55O07.85M05.86M05.60M07.40I10.84D06.02X10.66T07.38P16. 55Y SEAL PACKING 55O MACHINE UNGUARDED INSTALL GUARD 85M... | $0 | $0 | Aug 14, 2008 |
| Jun 23, 2008 | 38185823L | RESOLVE | Non-Hazardous | 83X09. 23X ENTIRE DEVICE REMOVE FILE WITH DOB TO REMOVE DEVICE WORK W/O A PERMIT | $0 | $0 | Aug 14, 2008 |
| Oct 19, 2005 | 38155535J | RESOLVE | Non-Hazardous | 16L11/38O02/21B06/69K10 16L11 SLOW SPEED HALL DOOR IS EFFECT OF LOOSE WITH DOOR CLOSER REPAIR AS NEEDED. 21B06 LOOSE ... | $0 | $0 | Dec 8, 2005 |
| May 21, 2002 | 38122181K | RESOLVE | Non-Hazardous | 30O06/ 11D06/ 30- PROPERLY SECURE TOP OF SHAFT UNDER MACHINE. 11 - INSTALL GUARD ON LIGHT IN CAR | $0 | $0 | Jul 11, 2002 |
| Sep 23, 1998 | 38079495M | RESOLVE | Non-Hazardous | 75U 9# 50Y 57O 75 CURRENT 5YRS TEST PERFORM AND FILE 09 REPLACE CAR DOOR GUIDE SHOES 50 SEAL MACHINE 57 CKEAN OIT | $0 | $0 | Nov 12, 1998 |
| Sep 23, 1998 | 38079491P | RESOLVE | Non-Hazardous | 75U 37L 37D 50Y 57O 57R 75 CURRENT 5YR TEST PERFORM & FILE 37 CHANGE DEFECTIVE RESISTOR ON CONTROLLER 37 MOUNT TIMER ... | $0 | $0 | Nov 12, 1998 |
| Sep 23, 1998 | 38079492R | RESOLVE | Non-Hazardous | 75U,50E,50Y,64B,51O.75 CURRENT 5YRS TEST PERFORM & ILE 50 REMOVE NOISE ROM MACHIEN 50 PROPERLY SEAL MACHINE 64 SHORTE... | $0 | $0 | Nov 12, 1998 |
| Dec 1, 1997 | 38066992K | RESOLVE | Non-Hazardous | 75U,46U,36T,74M,46Q,30O,57O,53B,01I,50Y,50O,03I,09H,57T, 75- NO 5 YEAR SINCE 1991 46-NO 2 YEAR TEST 36-LABEL DOOR 74-... | $350 | $0 | Mar 5, 1998 |
| Dec 1, 1997 | 38066993M | RESOLVE | Non-Hazardous | 75U,46U,36T,74M,30O,57O,10I,31M,54G,54R,50Y,50O,11L,03I,09H, 75-NO FIVE YEAR TEST 1991 46-NO 2 YEAR TEST 36-LABEL DOO... | $350 | $0 | Mar 5, 1998 |
| Dec 1, 1997 | 38066994Y | RESOLVE | Non-Hazardous | 75U,46U,36T,74M,53Q,37G,54G,37D,03O,57O,22D, 75-NO 5 YEAR TEST SINCE 1991 46-NO 2 YEAR TEST 36-LABEL DOOR 74-PROVIDE ... | $350 | $0 | Mar 5, 1998 |
| Nov 3, 1995 | 38052151Z | RESOLVE | Non-Hazardous | 50Y,18J,73O,. (74) REPAIR WATER LEAKS IN MOTOR ROOM.(74B)REPLCE CONTACTS AND SKUNTS ON CONTROLLER AS NECESSARY. 74C E... | $100 | $0 | Feb 29, 1996 |
| Apr 25, 1994 | 34107998Y | RESOLVE | Hazardous | FAILURE TO SUBMIT A 3RD ROUND TECHNICAL REPORT PERIODIC INSPECTION OF EXTERIOR WALL AND APPURTENANCES AS REQUIRED BY ... | $400 | $0 | Jun 16, 1994 |
| Apr 22, 1993 | 38032695Z | RESOLVE | Non-Hazardous | 39R, (39) FILE FOR PERMIT AND HAVE TESTED IN THE PRESENCE OF A MEMGER OF THIS DEPARTMENT | $1,000 | $0 | Jun 17, 1993 |
| Feb 6, 1991 | 38004825J | RESOLVE | Non-Hazardous | 73#,73 5 YEAR TEST & FILE | $150 | $0 | Jul 25, 1991 |
| Feb 6, 1991 | 38004427Y | RESOLVE | Non-Hazardous | 73#,73-5 YEAR TEST&FILE | $150 | $0 | Jul 25, 1991 |
| Feb 6, 1991 | 38004426M | RESOLVE | Non-Hazardous | 73#,73-5 YEAR TEST &FILE | $150 | $0 | Jul 25, 1991 |