ECB violations
200-214 West 37 Street, Manhattan • Block 00786 • Lot 0051
108 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Apr 11, 2024 | 37027689J | RESOLVE | CLASS - 2 | FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 9B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WA... | $0 | $0 | Jul 11, 2024 |
| Aug 10, 2021 | 35556284M | RESOLVE | CLASS - 1 | FAILURE TO DESIGNATE AND/OR HAVE SITE SAFETY MANAGER/SITE SAFETY COORDINATOR OR QSP PRESENT AT SITE AS REQUIRED.AT TH... | $2,500 | $0 | Aug 11, 2022 |
| Nov 18, 2020 | 35509290R | RESOLVE | CLASS - 2 | SEC. 3307.7.8 FENCE NOT PAINTED AS PER CODE. NOTE: AT TIME OF MY INSPECTION OF A 24 STY BLDG I OBSEERVEED AN INSTALLE... | $1,280 | $0 | Feb 4, 2021 |
| Nov 18, 2020 | 35509289J | RESOLVE | CLASS - 1 | WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENT. NOTE: AT TIMEOF MY INSPECTION OF 24 STY BLDG UNDER ALT-1 PER... | $2,530 | $0 | Feb 4, 2021 |
| Jul 15, 2020 | 39025461R | RESOLVE | CLASS - 2 | HOIST MACHINE BRAKE MAINTENANCE TAG EXPIRED PROVIDE. MAINTENANCE LOG UPDATE MISSING PROVIDE. | $312 | $0 | Sep 3, 2020 |
| Jul 15, 2020 | 39025459H | RESOLVE | CLASS - 2 | DLM NOT WORKING ON FIRE TEST PHS 11 CAR GATE SWITCH, REPAIR , MACHINE BRAKE MAINTENANCE TAG EXPIRED PROVIDE, MAINTENA... | $312 | $0 | Sep 3, 2020 |
| Apr 12, 2019 | 38268792L | RESOLVE | CLASS - 2 | 40D7,77M7,16J1,15L7. 40D7-MACHINE ROOM SLAB HAV CUTOUT THAT TO BE CLOSED AND MACHINE DIRTY CLEAN; 77M7-UNDERSIDE PLAT... | $0 | $0 | Jun 6, 2019 |
| Apr 21, 2014 | 36018852J | RESOLVE | CLASS - 2 | FAILUER TO FILE AN ACCEPTABLE CYCLE 7 TECHNICAL REPORT IN COMPLIANCE WITH CODE PROVISIONS: PERIODIC INSPECTION OF EXT... | $0 | $0 | Aug 21, 2014 |
| Sep 19, 2013 | 35021861M | RESOLVE | CLASS - 1 | UNAPPROVED/UNSAFE/UNSUITABLE ELECTRICAL EQUIPMENT,APPARATUS,MATERIALS,DEVICES,APPLIANCES OR WIRING IN USE. THE ENTIRE... | $1,600 | $0 | Nov 7, 2013 |
| Sep 19, 2013 | 35021860K | RESOLVE | CLASS - 1 | ELECTRICAL WORK W/O A PERMIT. THE ENTIRE NORTH SIDE ON 17 FLOOR: NO APP ON FILE FOR TEMPORARY ELECTRICAL INSTALLATION... | $1,600 | $0 | Nov 7, 2013 |
| Nov 2, 2012 | 38222037Y | RESOLVE | CLASS - 2 | 52K11 - REPLACE RUSTED AND UNDERSIZED HOIST ROPES. | $0 | -$530 | Dec 12, 2013 |
| Nov 2, 2012 | 38222038X | RESOLVE | CLASS - 2 | 52K11 - REPLACE RUSTED AND UNDERSIZED HOIST ROPES. | $250 | $0 | Dec 20, 2012 |
| Jun 29, 2011 | 38216074M | RESOLVE | CLASS - 2 | 16D06 34D06 34I10. 16D06-PROVIDE INTERLOCKS OLD DOORS IN SHAFTWAY 18TH FLR 19, 20,22,23,24 FLRS. 34D06-GUARD EXSISTIN... | $0 | $0 | Aug 18, 2011 |
| May 7, 2010 | 34836335N | RESOLVE | CLASS - 2 | FAILURE TO PROVIDE PLANS AT JOB SITE AT TIME OF INSPECTION. NOTED: THECONSTRUCTION OF A SHED IN PROGRESS UNDER PMT #1... | $0 | $0 | Jul 1, 2010 |
| May 7, 2010 | 34836334L | RESOLVE | CLASS - 1 | SEC. 3307.4.2. FAILURE TO PROVIDE MEASURE TO WARM THE PUBLIC OF AN ONGOING CONSTRUCTION OPERATIONS. NOTED: WHILE EREC... | $0 | $0 | Dec 2, 2010 |
| Feb 21, 2010 | 34829330Z | RESOLVE | CLASS - 1 | USE OF SUPPORTED SCAFFOLD WITHOUT A SCAFFOLD USER CERTIFICATE.NOTED:SCAFFOLD AT FRONT ENTRANCE FIFTEEN FEET HIGH BEIN... | $0 | $0 | Apr 15, 2010 |
| Feb 8, 2010 | 38209204X | RESOLVE | CLASS - 2 | 100X10.16M8.70T15.11B10.100 FL PASSING SIGNAL INOPERATIVE 16 PROVIDE SIGHT GUARD IN LOBBY 52 HOIST ROPES DIRTY 60 PRO... | $0 | $0 | Apr 1, 2010 |
| Feb 8, 2010 | 38209205H | RESOLVE | CLASS - 2 | 62L10.11 62 EXCESSIVE AWING ON HOIST MACHINE REPAIR REPLACE HIGH BARS OR LOW BARS ON COMMUTATOR | $0 | $0 | Apr 1, 2010 |
| May 22, 2009 | 36009143M | RESOLVE | CLASS - 2 | FAILURE TO FILE AN AMENDED SIXTH ROUND REPORT ACCEPTABLE TO THIS DEPT INDICATING CORRECTION OF UNSAFE CONDITIONS DESC... | $400 | $0 | Jun 24, 2010 |
| Jan 16, 2009 | 38199499X | RESOLVE | CLASS - 2 | 62L10.62L10 REPAIR GEARLESS MACHINE MOTOR COMMUTATOR # 9 CAR | $2,500 | $0 | Mar 12, 2009 |
| Jan 16, 2009 | 38199498Y | RESOLVE | CLASS - 2 | 62L10.62L10.REPAIR GEARLESS MACHINE MOTOR COMMUTATOR # 8 CAR | $2,500 | $0 | Mar 12, 2009 |
| Nov 7, 2008 | 36000660J | RESOLVE | CLASS - 2 | FAILURE TO FILE AN AMENDED 6TH ROUND REPORT ACCEPTABLE TO THIS DEPARTMENT INDICATING CORRECTION OF UNSAFE CONDITIONS ... | $0 | $0 | Mar 26, 2009 |
| Oct 22, 2008 | 34709692J | RESOLVE | CLASS - 2 | STOP-WORK-ORDER IN EFFECT FORA ALL BLDGS 100FT OR MORE IN HEIGHT SHED SHALL BE EXTENDED 20FT BEYOND BLDG STRUCTURE | $2,400 | $0 | Dec 11, 2009 |
| Oct 22, 2008 | 34709691H | RESOLVE | CLASS - 1 | STOP-WORK-ORDER IN EFFECT 10/21/08 FAILURE TO NOTIFY THE DEPT. OF AN ACCIDENT REMEDY:COMPLY WITH CODE | $0 | $0 | Jun 5, 2009 |
| Oct 21, 2008 | 34702280L | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD ALL PERSONS AND PROP AFFECTED BY CONST OPERATIONSNOTED: PERMIT 104752849 EXPIRE 11/25/08 REAR FA... | $2,400 | $0 | Apr 8, 2010 |
| Mar 28, 2008 | 34684186Z | RESOLVE | Non-Hazardous | FAILURE TO FILE AN AMENDED 6TH ROUND REPORT ACCEPTABLE TO THIS DEPT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRI... | $700 | $0 | May 14, 2009 |
| Oct 2, 2007 | 34418468P | RESOLVE | Hazardous | LOCAL LAW REPORT FILED AS "UNSAFE" UNSAFE CONDITION EXISTED & NO MEASURES TAKEN TO SECURE SAFETY OF PUBLIC AS PER 27-... | $800 | $0 | Nov 29, 2007 |
| Mar 9, 2007 | 38165201Z | RESOLVE | Non-Hazardous | 39B10,39O07.39B10-REPAIR CEILING & WALL CRACKS.39O02-PROPERLY CLEAN MACHINE ROOM & REMOVE OLD EQUIPMENT IN MACHINE RO... | $350 | $0 | Jun 28, 2007 |
| Jun 30, 2006 | 38160126P | RESOLVE | Non-Hazardous | 83X10/66O02/39Q06. (83)ENTIRE DEVICE INOPERATIVE; RESTORE TO SERVICE (66)PIT DIRTY CLEAN (39)MACHINE ROOM WALLS HAVE ... | $350 | $0 | Mar 22, 2007 |
| Jun 16, 2006 | 38159537L | RESOLVE | Non-Hazardous | 51-Q-03 | $350 | $0 | Mar 22, 2007 |
| Jun 16, 2006 | 38159536J | RESOLVE | Non-Hazardous | 51-Q-03 | $180 | $0 | Aug 3, 2006 |
| Sep 15, 2003 | 38141855L | RESOLVE | Non-Hazardous | 39B09,03O09. 39- REMOVE STORED MATERIALS FROM ACCESS TO MOTOR ROOM, 03- REMOVE REFUSE FROM CAB SO AN INSPECTION CAN C... | $2,500 | $0 | Mar 4, 2004 |
| Oct 28, 2002 | 38125963Z | RESOLVE | Non-Hazardous | -35P7. 35-P-07 EXCESSIVE STORAGE BLOCKING ACCESS TO MOTOR ROOM REMOVE ALL. | $180 | $0 | Jan 30, 2003 |
| Sep 4, 2002 | 38124842H | RESOLVE | Non-Hazardous | 30R09 REMOVE NONE ELEVATOR EQUIPMENT FROM SAFTWAY SHAFTWAY MUST BE CLEAR. | $180 | $0 | Oct 24, 2002 |
| Apr 17, 2002 | 38122738Z | RESOLVE | Non-Hazardous | 43Y14-05I11-57O02. 43-SEAL PUMP UNIT IN ROOM 05-REPAIR AND ALIGNED CAR GATE FOR PROPER MOVEMENT 57-CLEAN PIT. | $0 | $0 | Jun 6, 2002 |
| Mar 6, 2002 | 38122083R | RESOLVE | Non-Hazardous | 53B10/50O02/54U16/40O02/74R09/74I11/74Q12/60I12/57O02. 53B10 MOTOR ROOM IS NOT SUFFICIENT. RENEW LIGHTING TO PROVIDE ... | $2,500 | $0 | Sep 11, 2003 |
| Mar 6, 2002 | 38122084Z | RESOLVE | Hazardous | 01R12/43B11. 01R12 EMERGENCY STOP SWITCH IS OF KEY OPERATED- PROVIDE PROPER STOP SWITCH AS PER RS 8 BUILD CODE CALL D... | $500 | $0 | Apr 25, 2002 |
| Feb 26, 2002 | 38121479Z | RESOLVE | Non-Hazardous | 54U16/40O02/74B09/50O02/74B04/37H12/74O02/61B01/15B01. 54U16 PROPERLY TAG DEVICE WITH CITY NO. 74B09 REMOVE ANGLE IRO... | $180 | $0 | Apr 18, 2002 |
| Feb 26, 2002 | 38121478R | RESOLVE | Non-Hazardous | 50O02/40O02/50B11/52H12/50F11/53B10/54U16/30I04/18B11/11Q03/16L11/74I12/57O02/74O02. 50B11 MACHINE COMUTATOR CHATTERI... | $180 | $0 | Apr 18, 2002 |
| Feb 26, 2002 | 38121477P | RESOLVE | Non-Hazardous | 74B03/74I11/74B12/74I12. 74B03 TRANSFORMER MUST BE COVERED INSTALL COVER. 74I11 INSPECTION REVEALS WATER DAMAGE WALL ... | $180 | $0 | Apr 18, 2002 |
| Feb 26, 2002 | 38121476N | RESOLVE | Non-Hazardous | 74B03/74B09/40Q12/41Q1274B09+ 417E11. 74B03 TRANSFORMER MUST BE COVERED. INSTALL COVER 74B09 REMOVE LADDER FROM TOP O... | $180 | $0 | Apr 18, 2002 |
| Feb 25, 2002 | 38120973J | RESOLVE | Non-Hazardous | 26B01 27B01 74M12 08V01. 26 & 27 B01 ADJUST LIMITS TO TERMINAL LANDING 16TH FLOOR NOT 17 FL. 74M12 REPLACE MISSSSING ... | $350 | -$180 | Apr 11, 2002 |
| Feb 25, 2002 | 38120974L | RESOLVE | Non-Hazardous | 26B01/ 27B01/ 46Q03/ 55X11/ 26 & 27 B01 PROPERLY ADJUST LIMITS TO TERMINAL LANDING 23RD FLOOR INSTALL SECONDARY GUARD... | $350 | $0 | Apr 11, 2002 |
| Feb 25, 2002 | 38120971X | RESOLVE | Non-Hazardous | 26B01, 27B01, 22W06, 74M12. 2627 B01 PROPERLY ADJUST LIMITS TO TERMINAL LANDING 16TH FLOOR NOT 17 22W06 PROPERTY SECU... | $350 | $0 | Apr 11, 2002 |
| Feb 25, 2002 | 38120975N | RESOLVE | Non-Hazardous | 50M12, 46Q03, 74L11, 18M12. 50M12 REPLACE MACHINE STERRCEL #5 46Q03 SECONDARY GUARDS ON HOIST ROPE REPLACE GUARDS 74L... | $350 | $0 | Apr 11, 2002 |
| Feb 25, 2002 | 38120972H | RESOLVE | Non-Hazardous | 26B01, 27B01, 74M12, 15I11. 26 & 27 BO1 PROPERTY ADJUST LIMITS TO TERMINAL LANDINGS 16TH FL NOT 17TH FL 74M12 REPLACE... | $350 | $0 | Apr 11, 2002 |
| Feb 11, 2002 | 38120960K | RESOLVE | Non-Hazardous | 47H15/ 74Q03/ 46M12/ 47H15 GOVENOR ROPE HAS ROPE STRECH - PROPERLY SHORTEN ROPE 74Q03 TOP OF CAR LIGHT GUARDS INSTALL... | $180 | $0 | Mar 28, 2002 |
| Nov 13, 2001 | 38119043P | RESOLVE | Hazardous | CEASE USE/ 50L11/ 51L11/ 74L12/ 57O02/ 51L CEASE USE OF ELEVATOR UNTIL WORM & GAER HAVE BEEN REPAIRED CALL 1-646-2488... | $500 | $0 | Jan 3, 2002 |
| Nov 13, 2001 | 38119044R | RESOLVE | Non-Hazardous | 57O02/ 62D06/ 62 SECURE WIRING UNDER CAR PLATFORM | $0 | $0 | Jan 3, 2002 |
| May 1, 2000 | 38097329X | RESOLVE | Non-Hazardous | 02L11. 02-REPAIR ALARM BELL | $0 | $0 | Jun 22, 2000 |