ECB violations
257-261 West 38 Street, Manhattan • Block 00788 • Lot 0016
72 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Aug 1, 2023 | 35671094P | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING EXTERIOR WALLS FACADE AND APPURTENANCES: AT THE TIME OF INSPECTION OBSERVED CRACK COPING... | $0 | $0 | Mar 14, 2024 |
| Oct 5, 2022 | 39071482N | RESOLVE | CLASS - 1 | CLASS 1 CAR CEASE USE ,DOOR ZONE RESTRICTOR NOT WORKING TAMPERED WITH OR DISABLED (CU) 2/X/10 ALARM BELL INSIDE CAR D... | $0 | $0 | Aug 24, 2023 |
| Mar 3, 2021 | 35548981H | ACTIVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG EXTERIOR WALLS/FACADE & APPURTENANCES.NOTE:ATTHE TIME OF INSPECTION OBSERVED AT EXPO #1 SOUT... | $1,250 | $0 | Aug 12, 2021 |
| Nov 29, 2018 | 38266129X | RESOLVE | CLASS - 2 | 2X10,16D4,16B7-2X10)PROVIDE OUTSIDE COMMUNICATION. 16D4)PATCH HOLES IN HOISTWAY DOORS. 16B7)PROVIDE GUARD FOR TOP OF ... | $0 | $0 | Mar 7, 2019 |
| Apr 6, 2018 | 38262051R | RESOLVE | CLASS - 2 | 97X10 RESTORE TO SERVCIE AS PER CODE OF NYC DOB IMMEDIATELY. | $625 | $0 | May 24, 2018 |
| Jan 24, 2018 | 35264847M | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE & APPURENTCES.AS NOTED:EXPOSURE 1,SPALLED TERRACOTTA WATER TABLE,CRACKS ... | $0 | $0 | Jun 14, 2018 |
| May 3, 2017 | 38254672J | RESOLVE | CLASS - 1 | 5X7,2X10,24B10,39B10. 5X7-DOOR RESTRICTOR INOPERATIVE PROVIDE BRACKETON DOOR TRACK; 2X10-REPAIR ALARM BELL INOPERATIV... | $2,500 | $0 | Jun 22, 2017 |
| Nov 30, 2016 | 38251509X | RESOLVE | CLASS - 2 | 56Y13,61M7,42N9,40M7. 56Y13-HAVY OIL UNDER MACHINE SEAL; 61M7-PROVIDESERVICE STICKER ON MAIN LINE;42N9-REMOVE BLOCK R... | $0 | $0 | Jan 19, 2017 |
| Nov 30, 2016 | 38251507M | RESOLVE | CLASS - 1 | 7X1,2B10,24B10,59B1,40B15. 7X11-DOOR RESTRICTOR IS INOPERATIVE ADJUST2B10-ALARM BELL INSUFFICIENT DOES NOT RING REPAI... | $1,000 | $0 | Feb 16, 2017 |
| Nov 30, 2016 | 38251510N | RESOLVE | CLASS - 1 | 59B10,7X1,2B10,40B7. 59B10-ELECTRICAL BREAK CONTRACT IS MISSING ONE CONTACT; 7X1-DOOR RESTRICTOR IS INOPERATIVE ADJUS... | $1,000 | $0 | Feb 16, 2017 |
| Aug 31, 2015 | 38238509J | RESOLVE | CLASS - 2 | 97X10,100M05, 97X10-DEVICE OUT OF SERVICE,REPAIR TO BRING BACK IN SERVICE; 100M07-NTC ID TAG MISSING IN CAR PROVIDED ... | $250 | $0 | Oct 15, 2015 |
| Aug 18, 2015 | 38238531X | RESOLVE | CLASS - 2 | 97X10 ELEVATOR NOT WORKING. RETURN TO SERVICE. | $0 | $0 | Oct 8, 2015 |
| Aug 18, 2015 | 38238530Y | RESOLVE | CLASS - 2 | 02L10 OUTSIDE COMMUNICATION DEFECTIVE. PHONE IS NOT CONNECTED. PROVIDECOMMUNICATION. | $0 | $0 | Oct 8, 2015 |
| Jan 11, 2011 | 38214474M | RESOLVE | CLASS - 2 | 97X10 98BB05 98M07 99BB05 99M07 97X-RETURN TO SERVICE 98BB-AS PER DOB RECORDS 99BB-AS PER DOB RECORDS | $250 | $0 | Mar 3, 2011 |
| Oct 19, 2010 | 38211945X | ACTIVE | CLASS - 2 | 97X10 - REPAIR ELEVATOR AND RESTORE TO SERVICE | $500 | $0 | Dec 9, 2010 |
| Sep 16, 2010 | 38212909N | ACTIVE | CLASS - 2 | 97/X/#/37X#-ENTIRE DEVICE INOPERATIVE-RESTORE DEVICE BACK TO SERVICE | $500 | $0 | Nov 18, 2010 |
| Aug 9, 2010 | 38210992Y | ACTIVE | CLASS - 2 | 97/X/10-97-X-10-ELEVATOR DEVICE 1P15541RETURN TO SERVICE.RECURRING CONDITION.PRIOR ECB VIOLATION 38211110H | $500 | $0 | Sep 30, 2010 |
| Jun 29, 2010 | 38208221N | ACTIVE | CLASS - 2 | 97X10 - 97 RESTORE ELEVATOR BACK TO SERVICE | $500 | $0 | Aug 19, 2010 |
| Jun 1, 2010 | 38211109K | RESOLVE | CLASS - 3 | 42B11,45M13,41B01,67X10,12L11. 42B- REPLACE CONTROLLER DOOR PANEL WITHCITY ID TAG. 15M- PROPERLY CALIBRATE GOVERNOR &... | $0 | $0 | Jul 22, 2010 |
| Jun 1, 2010 | 38211110H | RESOLVE | CLASS - 3 | 12L11,67X10,42B11,56Y11. 12L- REPLACE DEFECTIVE LIGHT BULBS. 42B- REPLACE CONTROLLER. DOOR PANEL WITH CITY ID TAG. 56... | $0 | $0 | Jul 22, 2010 |
| Jun 1, 2010 | 38211108Z | ACTIVE | CLASS - 2 | 97X10. 97X- DEVICE FOUND INOPERATIVE- RESTORE DEVICE BACK TO SERVICE CALL DOB FOR INSPECTION | $500 | $0 | Jul 22, 2010 |
| Jan 11, 2010 | 38208206P | ACTIVE | CLASS - 2 | 97.97 ELEVATOR UNDER C.U RECURRING CONDITION RESTORE AND REPAIR ELEVATOR BACK TO SERVICE | $1,250 | $0 | Mar 4, 2010 |
| Dec 4, 2009 | 38205824Z | ACTIVE | CLASS - 2 | 97X10.97 RECURRING CONDITION RESTORE BACK TO SERVICE | $500 | $0 | Jun 24, 2010 |
| Nov 13, 2009 | 38205820L | ACTIVE | CLASS - 2 | 97X10.RESTORE ELEVATOR BACK TO SERVICE RECURRING CONDITION ON C.U | $2,500 | $0 | May 20, 2010 |
| Oct 29, 2009 | 38205819Y | ACTIVE | CLASS - 2 | 97X10. 97-UNDER CEASE USE. RECURRING CONDITION RESTORE ELEV BACK TO SERVICE | $500 | $0 | Dec 24, 2009 |
| Oct 19, 2009 | 38205815R | ACTIVE | CLASS - 2 | 97X10.97 RECURRING CONDITION RESTORE ELEVATOR BACK TO SERVICE | $500 | $0 | Dec 17, 2009 |
| Sep 8, 2009 | 38205294K | ACTIVE | CLASS - 1 | CU 97L10 44H10/11 60Q03 42L10 69M07 12Q03 46M07 64A15 97-CAR STARTING TO OVERSPEED IN DOWN DIRECTION W/ CAPACITY REPA... | $1,000 | $0 | Oct 29, 2009 |
| Sep 8, 2009 | 38205295M | RESOLVE | CLASS - 1 | CEASE USE ITEM 59X10 - BRAKE MONITOR INSPECTIVE REPAIR CALL 212-566-5542 TO OBTAIN TO SERVICE | $1,000 | $0 | Oct 29, 2009 |
| Mar 31, 2009 | 32066488N | RESOLVE | CLASS - 3 | 36,50A,B,C. FULTON VT BOILER,10HP,NB 82217,GAS FIRED,1998.36-REFERENCED HIGH PRESSURE STEAM BOILER IN OPERATION IS NO... | $0 | $0 | May 21, 2009 |
| Mar 17, 2008 | 32056161M | ACTIVE | Non-Hazardous | 50A,B,C,D,E,48A,B.HOT SHOT ELECTRIC HP STM BLR,4 SRW.50A-BLOWDOWN LINEREDUCED.INCREASE BLOWDOWN LINE TO UNIFORM SIZE.... | $2,500 | $0 | May 8, 2008 |
| Mar 17, 2008 | 32056160K | RESOLVE | Non-Hazardous | 50A,B,C.FULTON VT BOILER,10HP,NB 82217,GAS,1998.50A-IMPROPER ARRANGEMENT OF THE BLOWDOWN VALVES.INSTALL SCREW TYPE (S... | $0 | $0 | May 8, 2008 |
| Mar 4, 2008 | 32055977K | ACTIVE | Non-Hazardous | 50A,B.FULTON VT BOILER, 10HP,NB 72886, GAS 1995.50A-CLEAN OUT COVER ONFLUE PIPE MISSING.REPLACE.50B-IMPROPER ARRANGEM... | $180 | $0 | Apr 24, 2008 |
| Mar 4, 2008 | 32055978M | RESOLVE | Non-Hazardous | 50.FULTON VT BOILER,10HP,NB 64736,GAS,1992.50-NO STRUCTURE SUPPORTS ONTHE LOADED FLUE PIPE SYSTEM.INSTALL A HEAVY DUT... | $0 | $0 | Apr 24, 2008 |
| Mar 4, 2008 | 32055979Y | ACTIVE | Non-Hazardous | 36,50A,B.(REIMERS) ELECT MINIA HP STON BLR 8 KW 051909.36-REFERENCED ELECTRIC MINIATURE HIGH PRESSURE STEAM BOILER IS... | $350 | $0 | Aug 22, 2008 |
| Feb 21, 2008 | 38181337H | RESOLVE | Non-Hazardous | 84R04.84-DOOR & GATE BYPASS SWITCHES IN CONTROLLER OPERATIONS,DISARM SWITCHES. | $0 | $0 | Apr 28, 2008 |
| Feb 21, 2008 | 38181336X | ACTIVE | Non-Hazardous | 84R09,84L10.84-DOOR & ( )SWITCHES IN CONTROL OPERATIONS:( )SWITCH.84-WHY DOES PULLING M/L DISCONNECT ON THIS CAR MAKE... | $0 | $0 | Feb 13, 2009 |
| Dec 11, 2006 | 38162942M | RESOLVE | Non-Hazardous | 84R09-HOISTWAY DOOR& GATE BYPASS SWITCHES OPERATIONAL IN CONTROLLER REMOVE SWITCHED FROM OPERATION | $0 | $0 | Jan 25, 2007 |
| Dec 11, 2006 | 38162274X | RESOLVE | Non-Hazardous | 84R09 REMOVE ILLEGAL HOISTWAY DOOR & GATE BY PASS SWITCHES. | $0 | $0 | Jan 25, 2007 |
| Apr 25, 2006 | 32049965M | ACTIVE | Non-Hazardous | BQ9,36,44C,50. 1993 FULTON NB66457.50)FIRE DOOR ON BOILER ROOM HAS LOUVERS THAT MUST BE CONVERTED. | $850 | $0 | Nov 2, 2006 |
| Apr 25, 2006 | 32049964K | ACTIVE | Non-Hazardous | BQ9,50A,50B,36.1994 FULTON NB 72886.50A)PIPE DOWN GLASS DRAIN VALVE. 50B)HOLES IN WALL. | $680 | $0 | Jun 15, 2006 |
| Apr 25, 2006 | 32049967X | ACTIVE | Non-Hazardous | 6A,BQ9,36,50. HOT SHOT SUSSMAN 69580.6A) SET PRESSURE ON SAFETY VALVE IS 150PSI MINATURE BOILER IS RATED FOR 100PS.50... | $400 | $0 | Jun 29, 2006 |
| Apr 25, 2006 | 32049963Z | ACTIVE | Non-Hazardous | BQ9,50A,36,50D.1995 FULTON NB 72961.50A)HOLE IN WALL BY WINDOW.50B) HOLE IN WALL BY COMPRESSOR. | $5,000 | $5,000 | Jun 15, 2006 |
| Apr 25, 2006 | 32049966Y | ACTIVE | Non-Hazardous | 36,50A,50B,50C,50D.1988 FULTON NB 39169.50A)REPLACE MISSING RODS ON GLASS ASSEMBLY.50B)BOILER DOOR IS WOOD.50C)INSTAL... | $2,500 | $0 | Oct 12, 2006 |
| Dec 30, 2005 | 38156365K | RESOLVE | Non-Hazardous | 17H10. (17-H-10)REPAIR HOISTWAY DOOR GIBS. | $180 | $0 | Feb 16, 2006 |
| Feb 11, 2005 | 32046232L | RESOLVE | Non-Hazardous | 50A/50B. 1992 FULTON NATL BD 64381. 50A SEAL ALL HOLES ABOVE DOOR. 50B REPAIR DOOR IT IS FALLING DOWN WHEN YOU TRY TO... | $0 | $0 | Mar 31, 2005 |
| Jun 18, 2004 | 32044746J | ACTIVE | Non-Hazardous | 50A/50B FULTON V.T. BOILER, 10 HP, NB 63259, GAS-FIRED, 1991 50A IMPROPER ARRANGEMENT OF BLOWDOWN VALVES. REPLACE BAR... | $180 | $0 | Sep 2, 2004 |
| Jun 18, 2004 | 32044744X | RESOLVE | Non-Hazardous | 50 FULTON V.T. BOILER, 10HP, NB64736, GAS-FIRED, 1992 50 IMPROPER ARRANGEMENT OF BLOWDOWN VALVES. REPLACE EXISTING BA... | $0 | $0 | Aug 5, 2004 |
| Jun 18, 2004 | 32044745H | ACTIVE | Non-Hazardous | BQ9/18AB 44C/50A 50B FULTON V.T. BLR, 6HP, NB 32349, GAS-FIRED, 1976 REFERENCED BOILER WAS REMOVED FROM 262 WEST 38 S... | $850 | $0 | Aug 5, 2004 |
| Jun 18, 2004 | 32044743Y | ACTIVE | Non-Hazardous | 50A/50B 50C FULTON V.T. BOILER, 10HP, NB65468, GAS-FIRED, 1992 50A IMPROPER ARRANGEMENT OF BLOWDOWN VALVES. REPLACE E... | $180 | $0 | Aug 5, 2004 |
| May 8, 2002 | 32033833Y | ACTIVE | Non-Hazardous | 16, 36, 49. BQ9 27-147 FUCION HIGH PRESSURE BOILER FBOLOA NB #63259 BUILT 1991 INSTALLED WITHOUT A PERMIT FROM D.O.B.... | $850 | $0 | Sep 19, 2002 |