120 West 20 Street, Manhattan
Manhattan • Block 00795 • Lot 0054 • Zip: 10011
Condition
What the city currently has open against this building, counted from its own records.
Address
Land use and zoning
Building
Latest assessment
Neighborhood
The area this lot falls inside, and the commute Hoodkit measures from it.
Getting around
Estimated 3 days ago- Penn Station 9 min 3 walking, 6 riding
- Times Square 10 min 3 walking, 7 riding
- Union Square 16 min 3 walking, 13 riding
- Grand Central 18 min 3 walking, 15 riding
- Fulton Street 18 min 3 walking, 15 riding
- Downtown Brooklyn 23 min 3 walking, 20 riding
Around this address
Transit and places within 0.5 miles of the lot.
Getting out
Subway
Railroad
Ferry
Bus
Citi Bike
Places nearby
Cote
Cote is a modern Korean Steakhouse in the heart of NYC, offering a unique dining experience with premium cuts of meat...
Cafe Carmellini
No description yet
Eleven Madison Park
No description yet
Clemente Bar
No description yet
La Tete d’Or
No description yet
Breads Bakery
No description yet
Old Town Bar
No description yet
abcV
No description yet
Activity
Sales, filings, permits and violations from every dataset, in one order.
2025
-
CLASS - 1
FAILURE TO SECURE PUBLIC SAFETY AND MAKE THE BUILDING'S STRUCTURE AND APPURTENANCES CONFORM TO THE PROVISIONS OF THE ...
2024
2023
2016
-
CLASS - 2
59U15,68B7. NO TAG STATING DATE OF ANNUAL BRAKE MAINTENANCE, NO ENTRY OF DATE OF ANNUAL BRAKE MAINTENANCE IN LOG.
2015
-
Alteration Type II
ROOF DECK AND BULKHEAD RENOVATION AS PER PLANS FILED HEREWITH. NO CHANGE IN USE, OCCUPANCY, OR MEANS OF EGRESS.
-
HPD violation Oct 2, 2015
Class I
SECTION27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CO...
2014
2013
-
Alteration Type III
INSTALLATION OF SIDEWALK SHED AS PER PLANS. WORK SHALL COMPLY WITH 2008 BUILDING CODE CHAPTER 33. NO CHANGE IN USE EG...
-
Alteration Type II
LIMITED EXTERIOR REPAIRS TO THE NORTH, SOUTH, AND PARTIAL WEST FACADE. NO CHANGE TO USE EGRESS, OR OCCUPANCY.
-
DOB violation Aug 15, 2013
E-ELEVATOR ELEVATORREQUIRED
-
DOB violation Jan 31, 2013
FISPNRF-NO REPORT AND / OR LATE FILING (FACADE) FACADE REQUIRED
FAILED TO FILE FISP CYCLE 7A TECHNICAL REPORT BY 02/21/2012
2012
-
CLASS - 3
16B10- PATCH ALL HOISTWAY DOORS INSIDE HOISTWAY AROUND BUCK.
2011
-
DOB violation Dec 13, 2011
LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2010 INSPECTION REPORT
-
DOB violation Jun 14, 2011
E-ELEVATOR ELEVATORREQUIRED
2008
-
DOB violation Nov 20, 2008
E-ELEVATOR ELEVATORREQUIRED
-
DOB violation Feb 5, 2008
E-ELEVATOR ELEVATORREQUIRED
2005
-
Alteration Type III
INSTALLATION OF HEAVY DUTY SHED -25 ' LONG - DURING REMEDIAL REPAIRS. WORK SHALL COMPLY WITH LL33/91 NO CHANGE IN USE...
2003
-
Hazardous
FAILURE TO MAINTAIN EXTERIOR OF BLDG. LOOSE AND UNATTACHED FLOWER POTSON THE NORTH ELEVATION. POTS ARE ON THE 3RD AND...
2002
-
Alteration Type II
THE WORK INCLUDES, MASONRY REPAIRS FOR C OMPLIANCE WITH LOCAL LAW 11/98 NO CHANGE OF USE, EGRESS AND OCCUPANCY.
1998
-
Non-Hazardous
22D,35P,#P,#P, #-PROVIDE ACCESS TO OVERHEAD #-PROVIDE ACCESS TO FLOOR FOR INSPECTION ALL-FLOORS LOCKED OUT
The most recent 6 events from each dataset, so no one source takes the axis. Each tab holds the full record.
Property Contacts
Contact information aggregated from multiple government sources
Registration Contracts
Contact information from multiple dwelling registrations
Building Permits
Owner information from Department of Buildings filings
Recent Building Permits
Owner information from recent DOB NOW filings
Deed Records
Parties from ACRIS deed and mortgage records
Property Records
Owner information from assessment and PLUTO records