Maintenance code violations
191-195 7 Avenue, Manhattan • Block 00797 • Lot 0002
289 records
HPD grades a violation A for non-hazardous through C for immediately hazardous.
| Issued | Class | Status | Violation | Apartment | Correct by |
|---|---|---|---|---|---|
| Aug 27, 2024 | B | VIOLATION CLOSED | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE BOILER FLUE PIPE BY 1ST STORY AT REAR YARD | — | Oct 1, 2024 |
| Aug 27, 2024 | C | VIOLATION CLOSED | § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSE ELECTRICAL... | — | Sep 2, 2024 |
| Aug 27, 2024 | C | VIOLATION CLOSED | § 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION AT BACK FLOW CONTROL VALVE AT BOILER ROOM | — | Sep 2, 2024 |
| Aug 27, 2024 | C | VIOLATION CLOSED | § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSE ELECTRICAL... | — | Sep 2, 2024 |
| Aug 27, 2024 | C | FIRST NO ACCESS TO RE- INSPECT VIOLATION | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CL... | — | Sep 10, 2024 |
| Aug 27, 2024 | B | VIOLATION CLOSED | § 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE THE OBSTRUCTION IN FIREPROOF PASSAGEWAY KEY OPERATED LOCK SET ... | — | Oct 1, 2024 |
| Aug 27, 2024 | B | VIOLATION CLOSED | § 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE THE OBSTRUCTION IN FIREPROOF PASSAGEWAY GARBAGE CANS | — | Oct 1, 2024 |
| Aug 27, 2024 | C | VIOLATION CLOSED | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF HOUSEHOLD ITEMS AND WOOD FENCE PANELS OBSTRUCTING E... | — | Sep 2, 2024 |
| Aug 27, 2024 | C | VIOLATION CLOSED | § 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. ADJUST THE DROPLADDER SO THAT IT WILL SLIDE EASILY IN THE GUIDE RODS (GRAVI... | — | Sep 2, 2024 |
| Aug 27, 2024 | C | VIOLATION CLOSED | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CL... | — | Sep 10, 2024 |
| Aug 27, 2024 | C | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD LANDING IN BULKHEAD AT ROOF | — | Sep 2, 2024 |
| Aug 27, 2024 | A | VIOLATION CLOSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING AND ALL WALLS IN... | — | Nov 30, 2024 |
| Aug 27, 2024 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING A... | — | Oct 1, 2024 |
| Aug 27, 2024 | A | VIOLATION CLOSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE NORTH AND SOUTH WALLS AT... | — | Nov 30, 2024 |
| Aug 27, 2024 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT SOUTH WAL... | — | Oct 1, 2024 |
| Aug 27, 2024 | A | VIOLATION CLOSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE NORTH WALL AT PUBLIC HAL... | — | Nov 30, 2024 |
| Aug 27, 2024 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL FLOOR TILES AT PUBLIC HALL, 3r... | — | Oct 1, 2024 |
| Aug 21, 2024 | B | VIOLATION CLOSED | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 2B, 3rd STORY,... | 2B | Sep 25, 2024 |
| Aug 21, 2024 | B | VIOLATION CLOSED | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED A... | 2B | Sep 25, 2024 |
| Aug 21, 2024 | B | VIOLATION CLOSED | § 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES AT BATH TUB IN THE BATHROOM LOCATED AT APT 2... | 2B | Sep 25, 2024 |
| Aug 21, 2024 | B | VIOLATION CLOSED | § 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF COLD WATER FOR THE FIXTURES AT BATHTUB IN THE BATHROOM LOCATED AT APT 2... | 2B | Sep 25, 2024 |
| Aug 21, 2024 | B | VIOLATION CLOSED | § 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF COLD WATER FOR THE FIXTURES AT WASH BASIN IN THE BATHROOM LOCATED AT AP... | 2B | Sep 25, 2024 |
| Aug 21, 2024 | C | VIOLATION DISMISSED | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2B, 3rd ... | 2B | Sep 16, 2024 |
| Aug 19, 2024 | B | VIOLATION CLOSED | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 2B, 3rd STORY,... | 2B | Sep 23, 2024 |
| Aug 19, 2024 | B | VIOLATION CLOSED | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED A... | 2B | Sep 23, 2024 |
| Aug 19, 2024 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL FLOOR TILES IN THE KITCHEN LOC... | 2B | Sep 23, 2024 |
| Aug 19, 2024 | B | VIOLATION CLOSED | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED A... | 4A | Sep 23, 2024 |
| Aug 19, 2024 | B | FIRST NO ACCESS TO RE- INSPECT VIOLATION | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 1C, 2nd STORY,... | 1C | Sep 23, 2024 |
| Aug 19, 2024 | B | FIRST NO ACCESS TO RE- INSPECT VIOLATION | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED A... | 1C | Sep 23, 2024 |
| Aug 19, 2024 | B | FIRST NO ACCESS TO RE- INSPECT VIOLATION | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE NORTH WALL IN T... | 1C | Sep 23, 2024 |
| Aug 19, 2024 | B | FIRST NO ACCESS TO RE- INSPECT VIOLATION | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT NORTH WALL IN THE KITCHEN L... | 1C | Sep 23, 2024 |
| Aug 19, 2024 | B | FIRST NO ACCESS TO RE- INSPECT VIOLATION | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES IN THE KITCHEN L... | 1C | Sep 23, 2024 |
| Aug 19, 2024 | B | FIRST NO ACCESS TO RE- INSPECT VIOLATION | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND ALL... | 1C | Sep 23, 2024 |
| Aug 19, 2024 | B | FIRST NO ACCESS TO RE- INSPECT VIOLATION | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOC... | 1C | Sep 23, 2024 |
| Aug 19, 2024 | B | FIRST NO ACCESS TO RE- INSPECT VIOLATION | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE PORCELAIN ENAMEL GLAZE FINISH AT BAT... | 1C | Sep 23, 2024 |
| Aug 19, 2024 | B | FIRST NO ACCESS TO RE- INSPECT VIOLATION | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE NORTH WALL IN T... | 1C | Sep 23, 2024 |
| Aug 19, 2024 | B | VIOLATION CLOSED | 28 RCNY § 25-171; & 67 (7)(B) MDL; NYC FIRE CODE § 703.1.3; NYC FIRE CODE § 703.2: ADJUST DOOR TO PREVENT GAPS BETWEE... | 4A | Sep 23, 2024 |
| Aug 19, 2024 | C | VIOLATION CLOSED | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CL... | 4A | Sep 2, 2024 |
| Aug 5, 2024 | A | VIOLATION CLOSED | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10SQ FEET AT CEILING I... | 2R | Nov 8, 2024 |
| Aug 1, 2024 | B | VIOLATION CLOSED | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 2B, 3rd STORY,... | 2B | Sep 5, 2024 |
| Aug 1, 2024 | C | VIOLATION CLOSED | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CL... | 2B | Aug 15, 2024 |
| Jul 30, 2024 | A | NOV SENT OUT | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE NORTH WALL AT PUBLIC HAL... | — | Nov 2, 2024 |
| Jul 30, 2024 | B | NOV SENT OUT | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL NORTH WALL A... | — | Sep 3, 2024 |
| Jul 23, 2024 | C | FIRST NO ACCESS TO RE- INSPECT VIOLATION | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX 20 SQ FT AT WEST WALL IN ... | 2B | Aug 18, 2024 |
| Jul 22, 2024 | C | VIOLATION DISMISSED | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2B, 3rd ... | 2B | Aug 17, 2024 |
| Jul 22, 2024 | B | VIOLATION CLOSED | § 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF COLD WATER FOR THE FIXTURES AT WASH BASIN IN THE BATHROOM LOCATED AT AP... | 2B | Aug 26, 2024 |
| Jul 22, 2024 | B | VIOLATION CLOSED | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED A... | 2B | Aug 26, 2024 |
| Jul 22, 2024 | B | VIOLATION CLOSED | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 2B, 3rd STORY,... | 2B | Aug 26, 2024 |
| Jul 2, 2024 | B | DEFECT LETTER ISSUED | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... GREATER THAN 10 SQUARE FEET AT W... | 2B | Aug 6, 2024 |
| Jul 2, 2024 | B | VIOLATION CLOSED | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED A... | 2B | Aug 6, 2024 |