141-143 West 28 Street, Manhattan
Manhattan • Block 00804 • Lot 0013 • Zip: 10001
Condition
What the city currently has open against this building, counted from its own records.
Address
Land use and zoning
Building
Latest assessment
Neighborhood
The area this lot falls inside, and the commute Hoodkit measures from it.
Getting around
Estimated 3 days ago- Penn Station 9 min 3 walking, 6 riding
- Times Square 10 min 3 walking, 7 riding
- Union Square 16 min 3 walking, 13 riding
- Grand Central 18 min 3 walking, 15 riding
- Fulton Street 18 min 3 walking, 15 riding
- Downtown Brooklyn 23 min 3 walking, 20 riding
Around this address
Transit and places within 0.5 miles of the lot.
Getting out
Subway
Railroad
Ferry
Bus
Citi Bike
Places nearby
Cote
Cote is a modern Korean Steakhouse in the heart of NYC, offering a unique dining experience with premium cuts of meat...
Ambassadors Clubhouse
No description yet
Cafe Carmellini
No description yet
Keens Steakhouse
Keens Steakhouse is a legendary New York City institution known for its historic charm and exceptional steaks. The el...
Eleven Madison Park
No description yet
Clemente Bar
No description yet
Nan Xiang Xiao Long Bao
No description yet
Grandma’s Home
No description yet
Activity
Sales, filings, permits and violations from every dataset, in one order.
2024
-
CLASS - 2
OBSERVED IN THE BASEMENT WATER LEAKING INTO FRIGHT ELEVATOR SHAFT WHICH IS CONTRARY TO CODE SECTION PC301.3, REPAIR A...
2023
-
DOB violation Jun 30, 2023
HBLVIO-HIGH PRESSURE BOILER BOILER REQUIRED
VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL HGH PRESSURE INSPECTION
-
DOB violation Jun 30, 2023
HBLVIO-HIGH PRESSURE BOILER BOILER REQUIRED
VIOLATION ISSUED-FAILURE TO FILE 2021 INTERNAL HGH PRESSURE INSPECTION
-
DOB violation Jun 30, 2023
HBLVIO-HIGH PRESSURE BOILER BOILER REQUIRED
VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL HGH PRESSURE INSPECTION
-
DOB violation Jun 30, 2023
HBLVIO-HIGH PRESSURE BOILER BOILER REQUIRED
VIOLATION ISSUED-FAILURE TO FILE 2020 INTERNAL HGH PRESSURE INSPECTION
-
DOB violation Jun 30, 2023
LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED
VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION
-
DOB violation Jun 20, 2023
HBLVIO-HIGH PRESSURE BOILER BOILER REQUIRED
VIOLATION ISSUED-FAILURE TO FILE 2019 INTERNAL HGH PRESSURE INSPECTION
-
CLASS - 1
FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE AND APPURTENANCES.NOTE ATTIME OF INSPECTION 3/10/23,OBSERVED AT EXP4 EAS...
2022
2021
2019
-
CLASS - 2
A.C.27-929.1 FAILURE TO COMPLETE THE INSTALLATION OF A FULL YSTSEM OF AUTOMATIC SPRINKLERS AND FILE A FINAL SPRINKLER...
-
CLASS - 1
FAILURE TO MAINTAIN BUILDING EXTERIOR WALLS/FACADES AND APPURTENANCES.EXP1 SOUTH ELEVATION: CRACK AT STONE 3RD STORY,...
2016
-
Alteration Type II
FACADE REPAIRS AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
-
Alteration Type II
FILING FOR INSTALLATION OF A PRIVATE ROOF DECK AS PER PLANS SUBMITTED HEREWITH. NO CHANGE TO USE, EGRESS, OR OCCUPANCY.
-
Alteration Type III
INSTALLATION OF TEMPORARY SIDEWALK SHED AS PER PLAN SUBMITTED. WORK SHALL COMPLY WITH 2014 BUILDING CODES CHAPTER 33....
2013
-
Alteration Type II
MINOR INTERIOR PARTITION WORK, INSTALLATION OF THREE SPLIT-SYSTEM HVAC UNITS AND RELATED FRAMING. REPLACEMENT OF FOUR...
2012
-
Alteration Type II
PARTIAL STORE FRONT REPLACEMENT AND WALK-IN COOLER IN EXISTING RETAIL FLOWER STORE.NO CHANGE IN USE, OCCUPANCY OR EGR...
2011
2010
-
CLASS - 3
64M07 22M07 34O02 39O02 54B12 55B12 32H10 70O02 64M-PROVIDE CITY ID NUMBER TAG ON MAIN LINE & MACHINE 22M-PROVIDE PAR...
2006
-
Non-Hazardous
50A/50B/50C. 50A- HOLE IN WALL. 50B- DOOR MUST BE SHUT AT ALL TIMES. 50C- DEBRIS IN BOILER ROOM.
2004
-
Alteration Type III
INSTALLATION OF 88' HEAVY DUTY SIDEWALK SHED FOR FACADE REPAIR. NO CHANGE IN EGRESS, USE, OR OCCUPANCY. SHED TO COMPL...
The most recent 6 events from each dataset, so no one source takes the axis. Each tab holds the full record.
Property Contacts
Contact information aggregated from multiple government sources
Building Permits
Owner information from Department of Buildings filings
Recent Building Permits
Owner information from recent DOB NOW filings
Deed Records
Parties from ACRIS deed and mortgage records
Property Records
Owner information from assessment and PLUTO records