ECB violations
1-21 West 23 Street, Manhattan • Block 00825 • Lot 0031
89 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Oct 4, 2025 | 35685762Z | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING. AT TIME OF INSPECTION OBSERVED A CELLAR LEVEL UNPROTECTED RUBBER COATED WIRE(WITHOUT CO... | $2,500 | $0 | Feb 19, 2026 |
| Nov 15, 2019 | 37016230M | RESOLVE | CLASS - 2 | 27-929.1 A.C. 27-929.1,FAILURE TO COMPLETE THE INSTALLATION OF A FULL SYSTEM OF AUTOMATIC SPRINKLERS AND FILE A FINAL... | $625 | $0 | Feb 13, 2020 |
| Mar 27, 2019 | 38269076P | RESOLVE | CLASS - 1 | 59M7,97X17; 97.X.17 RESTORE TO SERVICE FOR PROPER INSPECTION BY D.O.B.59.M.7 MACHINE BRAKE TAG MISSING PROVIDE. | $1,250 | $0 | May 23, 2019 |
| Jul 28, 2017 | 35264285J | RESOLVE | CLASS - 2 | REMOVAL OF SIDEWALK SHED OR OTHER TYPES OF SAFETY MEASURES W/O DEPT'S APPROVAL. NOTED AT TIME OF INSPECTION BLDG FACA... | $0 | $0 | Jan 4, 2018 |
| Jun 20, 2017 | 37002399K | RESOLVE | CLASS - 2 | FAILURE TO FILE ANNUAL CERT THAT COOLING TOWER 1000001225 HAS BEEN INSPECTED,TESTED,& DISINFECTED, & THAT A MAINTENAN... | $1,000 | $0 | Oct 5, 2017 |
| Nov 18, 2016 | 35199793H | RESOLVE | CLASS - 2 | PSWO SUSPENDED SCAFFOLD. FAILURE TO PROVIDE PLANS FOR C-HOOKS. NOTED: AT TIME OF INSPECTION NO PLAN FOR C-HOOKS WITH ... | $250 | $0 | Jan 5, 2017 |
| Nov 18, 2016 | 35199792X | RESOLVE | CLASS - 2 | PSWO SUSPENDED SCAFFOLD. WORK DOES NOT CONFORM TO APPROVED CD-5. NOTEDAT TIME OF INSPECTION 3 SUSPENDED SCAFFOLD WITH... | $250 | $0 | Jan 5, 2017 |
| Apr 20, 2016 | 35158175J | RESOLVE | CLASS - 2 | PARTIAL STOP WORK ORDER FOR SUSPENDED SCAFFOLD AT THE CORNER AT 5AVE &23 ST ISSUED PURSUANT TO 28-207.2 & POSTED AT P... | $250 | $0 | Jun 9, 2016 |
| Apr 20, 2016 | 35158176L | RESOLVE | CLASS - 2 | SEC. 3301.10 OBSERVED LAWFUL SIGNS. NOTE: OBSERVED SIDEWALK SHED HAVE BEEN ERECTED AT EXP#1,2,3 TRAFFIC SIGNS HAVE BE... | $830 | $0 | Jun 9, 2016 |
| Feb 7, 2012 | 34916484R | RESOLVE | CLASS - 2 | WORK PERFORMED DOES NOT CONFORM TO CONSTRUCTION DOCUMENTS PRESENTED FOR APPLICATION #120632119 ALT 2 NON CONFORMANCE ... | $0 | $0 | Mar 29, 2012 |
| Jul 28, 2011 | 34915369R | RESOLVE | CLASS - 2 | NOTED THE FOLLOWING CONDITION WORKER WAS INJURED WHILE WORKING W/IN A CAUTION TAPED OFF AREA WORKERS ABOVE WERE INSTA... | $1,200 | $0 | Apr 5, 2012 |
| Jul 28, 2011 | 34915368P | RESOLVE | CLASS - 2 | NOTED THE FOLLOWING CONDITION WORKER WAS INJURED WHILE WORKING W/IN A CAUTION TAPED OFF AREA WORKERS ABOVE WERE INSTA... | $0 | $0 | Nov 10, 2011 |
| Mar 28, 2011 | 38215975P | RESOLVE | CLASS - 2 | 03E01 08O02 34O02 45O02 03E-RUBBING AND SCRAPING OF FASIAS ON 3-6FL 11TH FL 08O-LANDING SILLS-CLEAN | $250 | $0 | May 12, 2011 |
| Jul 23, 2010 | 34857972Z | RESOLVE | CLASS - 2 | FAILURE TO PROVIDE APPROVED/ACCEPTED PLANS @ JOB SITE @ TIME OF INSPECTION.NOTED:OBSERVED OUTRIGGER BEAM SET UP IN CO... | $0 | $0 | Sep 16, 2010 |
| Jul 23, 2010 | 34857973K | RESOLVE | CLASS - 2 | 3314.4.2)SUPPORTED SCAFFOLD DOES NOT MEET BLDG CODE SPECIFICATIONS.NOTED:SUPPORTED SCAFFOLD ERECTED @ THE REAR OF THE... | $800 | $0 | Sep 17, 2010 |
| Jul 23, 2010 | 34857971R | RESOLVE | CLASS - 1 | SUPERVISION OR USE OF RIGGING EQUIPMENT W/O A RIGGERS LICENSE.NOTED:O BSERVED MEN WORKING W/ 1)C-HOOKS IN CONNECTION ... | $4,800 | $0 | Sep 17, 2010 |
| Jan 5, 2009 | 34753108J | RESOLVE | CLASS - 1 | SUPERVISION OR USE OF RIGGING EQUIPMENT W/O A RIGGERS LICENSE NOTED APPROX 10 SUSPENDED SCAFFOLD IN OPERATION RIGGERS... | $4,800 | $0 | Feb 4, 2010 |
| Jan 5, 2009 | 34753110Z | RESOLVE | CLASS - 1 | NO RECORD OF DAILY INSPECTION OF SUSPENDED SCAFFOLD BY AUTHORIZED PERSONS AT SITE NOTED NO INSPECTION REPORT AVAILABL... | $2,400 | $0 | Feb 4, 2010 |
| Jan 5, 2009 | 34753109L | RESOLVE | CLASS - 1 | FAILURE TO PERFORM SAFE PROPER INSPECTION OF SUSPENDED SCAFFOLD NOTED THERE ARE INSUFFICIENT COUNTERWEIGHTS ON OUTRIG... | $10,000 | $0 | Feb 4, 2010 |
| Jan 5, 2009 | 34753111K | RESOLVE | CLASS - 2 | FAILURE TO PROVIDE APPROVED ACCEPTED PLANS AT JOB SITE AT TIME OF INSPECTION NOTE NO PLANS AVAILABLE FOR SIDE WALK SH... | $0 | $0 | Feb 26, 2009 |
| Oct 6, 2008 | 34709679P | RESOLVE | CLASS - 2 | WORK DOES NOT CONFORM TO APPROVED PLANS. CD-5 DOES NOT SHOW LOCATIONS OR RIGHT NUMBER OF RIGS. ALSO DOES NOT SHOW TIE... | $250 | -$250 | Jan 15, 2009 |
| Sep 25, 2008 | 36000224N | RESOLVE | CLASS - 1 | FAILURE TO FILE AFFIDAVITS AND/OR COMPLY W/ OTHER REQUIREMENTS SET FORTH FOR PHOTOLUMINESCENT EXIT PATH MARKING REMED... | $0 | $0 | Jan 8, 2009 |
| Aug 1, 2008 | 34685121M | RESOLVE | CLASS - 2 | SIDEWALK SHED DOES NOT MEET CODE SPECIFICATION: SUPPORTING LEG (COLUMN) ON SIDEWALK SHED AT S/E CORNER OF BLDG HAS MI... | $2,400 | $0 | Sep 25, 2008 |
| Jul 18, 2008 | 34684781N | RESOLVE | CLASS - 2 | WORK DOESN'T CONFORM TO APPROVED CONSTRUCTION DOCUMENTS OR APPROVED CONSTRUCTION DOCUMENTS OR APPROVED AMENDMENTS INA... | $250 | $0 | Oct 30, 2008 |
| Jan 3, 2008 | 34610005Z | RESOLVE | Non-Hazardous | PLUMBING WORK W/O A PERMIT. LOCATION: 2ND-14TH FLOORS DISCONNECTED & REMOVED SPRINKLER SYSTEM W/A PERMIT. REMEDY: OBT... | $800 | $0 | Feb 28, 2008 |
| Sep 14, 2007 | 34593728K | RESOLVE | Non-Hazardous | WORK W/O PERMIT EXPIRED PERMIT # 103980015 EXPIRED 4/1/07 FOR SIDEWALKSHED.REMEDY RENEW PERMIT | $2,500 | $0 | Nov 8, 2007 |
| May 19, 2007 | 34576650P | RESOLVE | Non-Hazardous | FAILURE TO COMPLY W/ COMMISSIONER'S ORDER TO CERTIFY CORRECTIONS.NOTEDWRITTEN BASED UPON NO RECORDS OF CORRECTION TO ... | $0 | $0 | Dec 20, 2007 |
| Jan 19, 2007 | 34556467Z | RESOLVE | Non-Hazardous | SEC.27-1009(B):FAILURE TO SAFEGUARD PUBLIC IN THAT SIDEWALK SHED WAS INSTALLED W/12FT HEIGHT ON 23RD & 24TH ST & 18FT... | $400 | $0 | Jun 14, 2007 |
| Jan 19, 2007 | 34556469M | RESOLVE | Hazardous | WORK W/O A PERMIT-REVOKED PERMIT FOR FAILURE TO COMPLY W/10-DAY LETTERDATED 1/2/07 TO PROVIDE REQUIRED INFORMATION ON... | $800 | $0 | Jun 14, 2007 |
| Jan 19, 2007 | 34556468K | RESOLVE | Non-Hazardous | WORK DOES NOT CONFORM TO APPROVED PLANS IN THAT SIDEWALK SHED WAS INSTALLED W/A 12FT HEIGHT ON 23RD & 24TH ST & 18FT ... | $250 | $0 | Jun 14, 2007 |
| Dec 11, 2006 | 34556451Y | RESOLVE | Non-Hazardous | FAILURE TO SAFEGUARD PUBLIC IN THAT SIDEWALK SHED WAS INSTALLED W/A 12FOOT HEIGHT ON 23RD & 24TH STREETS & 18 FOOT HE... | $2,500 | $0 | May 3, 2007 |
| Aug 7, 2006 | 38160857Z | RESOLVE | Non-Hazardous | 83X10/86U03 83-RETURN TO SERVICE FOR PROPER DOB INSPECTION 86-PERFORM 2 YEAR TEST. | $350 | $0 | Feb 15, 2007 |
| Aug 7, 2006 | 38159671M | RESOLVE | Non-Hazardous | 86U05 - 2 YEAR DUE. | $350 | $0 | Feb 15, 2007 |
| Aug 7, 2006 | 38159672Y | RESOLVE | Non-Hazardous | 86U05 - 2 YEAR DUE. | $350 | $0 | Feb 15, 2007 |
| Aug 7, 2006 | 38159673X | RESOLVE | Non-Hazardous | 83X10/86U05 83-RETURN TO SERVICE FOR PROPER DOB INSPECTION 86-PERFORM 2 YEAR TEST. | $350 | $0 | Feb 15, 2007 |
| Aug 7, 2006 | 38159674H | RESOLVE | Non-Hazardous | 83X10/86U05 83-RETURN TO SERVICE FOR PROPER DOB INSPECTION. 86-PERFORM2 YEAR TEST. | $350 | $0 | Feb 15, 2007 |
| Aug 7, 2006 | 38160850X | RESOLVE | Non-Hazardous | 83X10/86U05 83-RETURN TO SERVICE FOR PROPER DOB INSPECTION 86-PERFORM 2 YEAR TEST. | $350 | $0 | Feb 15, 2007 |
| Aug 7, 2006 | 38160851H | RESOLVE | Non-Hazardous | 83X10/86U05 83-RETURN TO SERVICE FOR PROPER DOB INSPECTION. 86-PERFORM2 YEAR TEST. | $350 | $0 | Feb 15, 2007 |
| Aug 7, 2006 | 38160852J | RESOLVE | Non-Hazardous | 83X10/86U05 83-RETURN TO SERVICE FOR PROPER DOB INSPECTION 86-PERFORM 2 YEAR TEST. | $350 | $0 | Feb 15, 2007 |
| Aug 7, 2006 | 38160853L | RESOLVE | Non-Hazardous | 83X10/86U05 83-RETURN TO SERVICE FOR PROPER DOB INSPECTION. 86-PERFORM2 YEAR TEST. | $350 | $0 | Feb 15, 2007 |
| Aug 7, 2006 | 38160854N | RESOLVE | Non-Hazardous | 83X10/86U05 83-RETURN TO SERVICE FOR PROPER DOB INSPECTION 86-PEFORM 2 YEAR TEST. | $350 | $0 | Feb 15, 2007 |
| Aug 7, 2006 | 38160855P | RESOLVE | Non-Hazardous | 83X10/86U05 83-RETURN TO SERVICE FOR PROPER DOB INSPECTION 86-PERFORM 2 YEAR TEST. | $350 | $0 | Feb 15, 2007 |
| Aug 7, 2006 | 38160856R | RESOLVE | Non-Hazardous | 83X10/86U05 83-RETURN TO SERVICE FOR PROPER DOB INSPECTION 86-PERFORM 2 YEAR TEST. | $350 | $0 | Feb 15, 2007 |
| Aug 2, 2006 | 38159670K | RESOLVE | Non-Hazardous | 83-X-10/86-U-05/83-X-10-ELEVATOR NOT IN SERVICE RETURN TO SERVICE FOR PROPER DOB ELEVATOR INSPECTION/86-U-05-2 YR TEST | $350 | $0 | Feb 15, 2007 |
| May 31, 2006 | 34526111K | RESOLVE | Non-Hazardous | NOTED:FAILURE TO POST CONTRACTOR'S SIGN. REMEDY:POST CONTRACTOR'S SIGN. REMEDY:POST CONTRACTOR'S SIGN. | $500 | $0 | Aug 24, 2006 |
| May 31, 2006 | 34526107H | RESOLVE | Non-Hazardous | NOTED:HAVING PROHIBITED SIGN ON A SIDEWALK SHED. REMEDY: REMOVE ILLEGAL WORK. | $400 | $0 | Aug 24, 2006 |
| May 31, 2006 | 34526108J | RESOLVE | Non-Hazardous | NOTED:HAVING INSTALLED A SIGN WITHOUT A PERMIT. REMEDY:REMOVE ILLEGAL WORK. | $400 | $0 | Aug 24, 2006 |
| May 31, 2006 | 34526109L | RESOLVE | Non-Hazardous | NOTED:HAVING PROHIBITED ADVERTISING SIGNAGE IN C5-2 DISTRICT. REMEDY:REMOVE ILLEGAL SIGNAGE. | $400 | $0 | Aug 24, 2006 |
| May 31, 2006 | 34526110Z | RESOLVE | Non-Hazardous | NOTED:HAVING SIGNAGE WITH A SURFACE AREA GREATER THAN 200 SQ.FT. IN C5-2 DISTRICT. REMEDY:REMOVE ILLEGAL SIGNAGE. | $400 | $0 | Aug 24, 2006 |
| Mar 23, 2006 | 34508558H | RESOLVE | Non-Hazardous | HAVING SIGNAGE WITH A SURFACE AREA MORE THAN 200 SQ FT. REMEDY: REMOVEILLEGAL SIGNAGE. | $800 | -$800 | Dec 21, 2006 |