ECB violations
37-43 West 26 Street, Manhattan • Block 00828 • Lot 0009
45 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Sep 27, 2022 | 35665600H | RESOLVE | CLASS - 1 | OCCUPANCY CONTRARY TO THAT ALLOWED BY THE COFO#102488158.ILLEGAL OCCUPANCY NOTED AT APT1209 HAS BEEN CONVERTED TO TRA... | $2,500 | $0 | Jun 1, 2023 |
| Sep 27, 2022 | 35665601J | RESOLVE | CLASS - 1 | 907.2.8 FAILURE TO PROVIDE CLASS"J"FIRE ALARM SYSTEM FOR TRANSIENT USEAT APT1209.REMEDY:DISCONTINUE ILLEGAL OCCUPANCY. | $2,500 | $0 | Jun 1, 2023 |
| May 20, 2022 | 39501559J | RESOLVE | CLASS - 2 | SIDEWALK SHED AT EXPO#1. EXPIRED ON 2-22-2022RENEW PERMIT | $0 | $0 | Jul 7, 2022 |
| Apr 13, 2021 | 35560005M | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN EXTERIOR BLDG FACADE OR APPURTENANCES.NOTE:ATOI,OBSERVED@1)EXP1,SELEVATION:CRACKED-CHIPPED STONE@... | $0 | $0 | Sep 30, 2021 |
| Feb 17, 2021 | 35549260M | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING EXTERIOR WALLS/FACADES AND APPURTENANCES.NOTE AT THE TIME OF INSPECTION OBSERVED AT EXPO... | $0 | $0 | Sep 23, 2021 |
| Jan 6, 2021 | 35549350X | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING EXTERIOR WALLS/FACADES AND APPURTENANCES.EXPOSURE 1,SOUTH ELEVATION:SPALLED MASONARY STO... | $0 | $0 | Feb 10, 2022 |
| Sep 29, 2020 | 37020287P | RESOLVE | CLASS - 2 | SEC. 27-929.1 FAILURE TO COMPLETE THE INSTALLATION OF A FULL SYSTEM OFAUTOMATIC SPRINKLERS & FILE A FINAL SPRINKLER R... | $625 | $0 | Dec 31, 2020 |
| Apr 12, 2013 | 38224593Y | RESOLVE | CLASS - 3 | 70I11- FOUND OLD, RUSTED AND DAMAGED PIPE RISER SECTION LOCATED IN THEELEVATOR PIT. REPLACE THIS SECTION OF PIPE IS T... | $0 | $0 | May 30, 2013 |
| Apr 1, 2012 | 34947498J | RESOLVE | CLASS - 2 | OPERATION OF A PLACE OF ASSEMBLY W/O A CURRENT CERT OF OPERATION. P.A.#103468533 FOR 199 PEOPLE EXPIRED 3-23-12. PREM... | $800 | $0 | Nov 9, 2012 |
| Apr 1, 2012 | 34947591Y | RESOLVE | CLASS - 2 | ALTERED/CHANGED BUILDING OCCUPIED W/O A VALID C OF O AS PER 28-118.3.128-118.3.2 TCO EXPIRED 3/19/12 TCO #103368071T0... | $0 | $0 | Nov 8, 2012 |
| Aug 1, 2009 | 34784109N | RESOLVE | CLASS - 2 | OCCUPANCY CONTRARY TO THAT ALLOWED BY THE C OF O. DEFECT IS: TEMPORARYC OF O #110351805T002 FOR GROUND LEVEL EATING &... | $0 | $0 | Sep 24, 2009 |
| Feb 28, 2009 | 34755431Z | RESOLVE | CLASS - 2 | OPERATION OF PLACE OF ASSEMBLY W/O A CURRENT CERTIFICATE OF OPERATION NOTED: PA PERMIT 108468533 EXPIRED 6/06. REMEDY... | $800 | $0 | Sep 2, 2010 |
| Oct 6, 2008 | 34709750Z | RESOLVE | CLASS - 1 | SS BC 3314.6.3 LIFELINES, TIE BACKS AND SUSPANSION ROPES SHALL EACH BY ATTACHED TO A DIFFERENT POINT OF ANCHORAGE. NO... | $0 | $0 | Apr 16, 2009 |
| Oct 6, 2008 | 34709599P | RESOLVE | CLASS - 1 | NO RECORD OF DAILY INSPECTION OF SUSPENDED SCAFFOLD PERFORMED BY AUTHORIZED PERSON AT SITE. NOTED: NO DAILY INSPECTIO... | $0 | $0 | Apr 17, 2009 |
| Dec 6, 2005 | 38154683R | RESOLVE | Non-Hazardous | 84B01/ 84/B CAR HAS BUMP WHEN IT CPMES TO A LANDING | $0 | $0 | Jan 26, 2006 |
| Nov 18, 2005 | 34499589Z | RESOLVE | Non-Hazardous | WORK W/O PERMIT EXPIRED PERMIT # 104186685 ON 09/21/05. REMEDY : RENEWPERMIT | $0 | $0 | Jan 5, 2006 |
| Jun 13, 2005 | 38153279K | RESOLVE | Non-Hazardous | 85BB05/51O02/63M07/55Y13/55O02/#M07 (85) CURRENT FIVE YEAR TAG EXPIREDPERFORM AND FILE TEST (51) HOIST ROPES DIRTY CL... | $0 | $0 | Jul 28, 2005 |
| Feb 10, 2005 | 34451817Z | RESOLVE | Non-Hazardous | ALTERED BUILDING OCCUPIED WITHOUT A VALID CERTIFICATE OF OCCUPANCY- ALT # 103368071- 1ST FLOOR AND MEZZ. C OF O EXPIR... | $350 | $0 | Mar 31, 2005 |
| Jan 16, 2004 | 34462716N | RESOLVE | Non-Hazardous | FAILURE TO SUBMIT A FIFTH ROUND TECHNICAL REPORTR:PERIODIC INSPECTION WALLS AND APPURTENACES AS REQUIRED BTY LOCAL LA... | $0 | $0 | Apr 15, 2004 |
| Nov 20, 2003 | 34417004M | RESOLVE | Hazardous | EXIT PASSAGEWAY OR CORRIDOR TOTAL OBSTRUCTION ON THE 7 FL EXIT PASSEWAY VEADING TO FIRE ESCAPE BLACK BY FREEZER FILE ... | $480 | $0 | Jan 8, 2004 |
| Jul 15, 2002 | 34312138R | RESOLVE | Hazardous | FAILURE TO MAINTAIN PLUMBING AND / OR APPURTENANCES HAZARDOUS. REMEDY ; MAINTIAN PLUMBING AND / OR APPURTENANUS LOCAT... | $800 | $0 | Apr 10, 2003 |
| Dec 27, 2001 | 34311935P | RESOLVE | Non-Hazardous | WORK WITHOUT A PERMIT: NTOED: 3 SKYLITES HAVE BEEN REMOVED (APPROX 6'X12') FROM THE ROOF OF SAID PREMISES IN WHICH 2 ... | $500 | $0 | Feb 14, 2002 |
| Nov 16, 2000 | 34266982H | RESOLVE | Non-Hazardous | WORK WITHOUT A PERMIT. NEW DUCTWORK FOR AIR CONDITION ON THE 12TH FL (ROOM 1209) HAS BEEN BRECTED. REMEDY:OBTAIN PERMIT. | $0 | $0 | Jan 18, 2001 |
| Feb 28, 2000 | 38095378N | RESOLVE | Non-Hazardous | 73X7,75U05,47B15, 73)RETURN TO SERVICE 75)FIVE YEAR TEST TAG 47)SHORTEN '50 A FULL INSPECTION CAN BE MADE | $0 | $0 | May 18, 2000 |
| Feb 28, 2000 | 38094700H | RESOLVE | Non-Hazardous | 75U05,50Y02,50Y14,32Q07, 75)FIVE YEAR TEST TAG 50)CLEAN MACHINE OF OIL50)SEAL MACHINE 32)PROVIDE COVERS UNDER CAR. | $0 | $0 | May 18, 2000 |
| Feb 28, 2000 | 38095377L | RESOLVE | Non-Hazardous | 75U05,50Y14,50Y02, 75)FIVE YEAR TEST TAG | $0 | $0 | May 18, 2000 |
| Feb 28, 2000 | 38095376J | RESOLVE | Non-Hazardous | 75U05,50Y14,50Y02,50A02, 75)FIVE YEAR TEST TAG.50,AND 50A)SEAL AND CLEAN MACHINE | $0 | $0 | May 18, 2000 |
| Apr 9, 1999 | 34206811Z | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN BUILDING. NOTED: AT 12TH FL. (1209). 1) NO INTER- COM; FLOOR BUCKELING DUE TO WATER DAMAGE FROM B... | $180 | $0 | Jun 3, 1999 |
| Apr 9, 1999 | 34206810R | RESOLVE | Non-Hazardous | WORK WITHOUT A PERMIT. NOTED: AT 12TH FL. (1209) PUBLIC STAIR BETWEEN 12TH FL. MEZZ AND 12 FL. ENCLOSED BY ERECTION O... | $250 | $0 | Jun 3, 1999 |
| Apr 9, 1999 | 34206812K | RESOLVE | Hazardous | EXIT DOOR - TOTAL OBSTRUCTION. NOTED: 12TH FL. (1209) AT MEZZANIE. 1) EXIT DOOR DEAD BOLTED FROM OUTSIDE; 2) PUBLIC H... | $0 | $0 | Oct 29, 1999 |
| Feb 13, 1998 | 38069885Z | RESOLVE | Non-Hazardous | 01B,35I,36I,40D,54R,14B,30O,62O,01-INSTALLED STOP BUTTOM AS REQUIRED 35-REPAIR HOLES IN MOTOR ROOM WALLS 36-REPAIR MO... | $0 | $0 | Sep 10, 1998 |
| Feb 13, 1998 | 38069888Y | RESOLVE | Non-Hazardous | 40D,30O,62O,02M,01L,14B, | $0 | $0 | Sep 10, 1998 |
| Feb 13, 1998 | 38069886K | RESOLVE | Non-Hazardous | 62O,30O,01B,40D,54R,14B, 62-CAR FRAME UNDERSIDE 01-INSTALL RED STOP 40SEAL GOVERNOR AT CORRECT SETTING. | $0 | $0 | Sep 10, 1998 |
| Feb 13, 1998 | 38069887M | RESOLVE | Non-Hazardous | 14B,35#,02M,01L,30O,62O,03I,40D,35-REPAIR BROKEN LIGHTS 02-PROVIDE ALARM BELL BUTTOM ON CAR 01-PROVIDE ALARM BELL ON ... | $0 | $0 | Sep 10, 1998 |
| Jun 6, 1997 | 34150862Z | RESOLVE | Hazardous | FAILURE TO FILE AN AMENDED ROUND FOUR REPORT ACCEPTABLE TO THIS DEPARTMENT PURSANT TO RULE R.C.N.Y. 32-03B(5), INDICA... | $400 | $0 | Sep 25, 1997 |
| Jan 26, 1995 | 34120559Z | RESOLVE | Non-Hazardous | WORK WITHOU PERMIT. NOTED: INTERIOR DEMOLITIN/REMOVAL OF NON-BEARING PARTITION WALLS FROM 2ND APPOX 6' X 8' . BATHROO... | $0 | $0 | May 22, 1997 |
| Jan 26, 1995 | 34120561H | RESOLVE | Non-Hazardous | WORK WITHOUT PERMIT:NOTED:INTERIOR DUNOLITION/REMOVAL OF NON-BEARING PARTITION WALLS FROM WALLS FROM 2MOS,APPOX.6X8 B... | $175 | $0 | Apr 13, 1995 |
| Jan 19, 1995 | 34119032Y | RESOLVE | Non-Hazardous | WORK WITHOUT A PERMIT--WORK NOTED: REMOVING NON-BEARING METAL. STUD PARTITIONS THROUGHOUT 3RD STORY. REMEDY: STOP ALL... | $175 | $0 | Mar 31, 1995 |
| Mar 31, 1993 | 34089522M | RESOLVE | Non-Hazardous | WORK WITHOUT A PERMIT: NOTED: INTERIOR DEMOLITION PARTITIONS. LOCATION: 11TH FLOOR ENTIRE. REMEDY: OBTAIN A PERMIT & ... | $0 | $0 | Jun 3, 1993 |
| Jun 25, 1992 | 38025986N | RESOLVE | Non-Hazardous | 39H 41Q 74 REMOVE ORMAKE PERMANENT EXPOSED WIRE CONNECTION FROM CONTEOLLR TO SELECTOR | $0 | $0 | Aug 6, 1992 |
| Jun 25, 1992 | 38025985L | RESOLVE | Non-Hazardous | 28H 46N 41Q 50Y | $0 | $0 | Aug 6, 1992 |
| Jun 25, 1992 | 38025987P | RESOLVE | Non-Hazardous | 41Q 46H 41Q- GOVERNOR SWITCH UNGUARDED 46H- HOIST CABLES WORN | $0 | $0 | Aug 6, 1992 |
| Jul 24, 1991 | 32008662Y | RESOLVE | Hazardous | 3(A) | $170 | $0 | Sep 26, 1991 |
| Mar 6, 1990 | 34038114N | RESOLVE | Non-Hazardous | WORK WITHOUT A PERMIT. REMEDY: FILE PLANS, OBTAIN PERMITS BEFORE CONTINUING WORK. | $250 | $0 | Apr 19, 1990 |
| Jul 20, 1989 | 34028168J | RESOLVE | Non-Hazardous | WORK WITHOUT A PERMIT NOTED INTERIRO DEMOLITION OF PARTITIONS NEW PARTITIONS CREATING A NEW OFFICE SPACE LOCATION 4 S... | $0 | $0 | Aug 31, 1989 |