Skip to content

ECB violations

18 West 27 Street, Manhattan • Block 00828 • Lot 0059

18 records

Environmental Control Board violations, which carry a hearing and a penalty.

Issued Violation Status Severity Description Penalty Balance due Hearing
Jun 17, 2024 37028783K RESOLVE CLASS - 2 A. C. 27-929.1, FAILURE TO COMPLETE THE INSTALLATION OF A FULL SYSTEM OF AUTOMATIC SPRINKLERS AND FILE A FINAL SPRINK... $6,250 $0 Sep 12, 2024
Feb 28, 2023 37025241M RESOLVE CLASS - 2 27-929.1 FAILURE TO COMPLETE INSTALLATION OF FULL SYSTEM OF AUTOMATIC SPRINKLERS & FILE FINAL SPRINKLER REPORT PREPAR... $3,125 $1,565 Jun 22, 2023
Nov 1, 2021 37022720X RESOLVE CLASS - 2 27-929.1 FAILURE TO COMPLETE THE INSTALLATION OF A FULL SYSTEM OF AUTOMATIC SPRINKLERS AND FILE A FINAL SPRINKLER REP... $3,125 $0 Oct 27, 2022
Nov 15, 2019 37016241H RESOLVE CLASS - 2 27-929.1 A.C. 27-929.1,FAILURE TO COMPLETE THE INSTALLATION OF A FULL SYSTEM OF AUTOMATIC SPRINKLERS AND FILE A FINAL... $1,250 $0 Feb 13, 2020
Apr 23, 2012 36018365M RESOLVE CLASS - 2 FAILURE TO FILE AN ACCEPTABLE 6TH ROUND TECHNICAL REPORT IN COMPLIANCEW/ARTICLE 28-302 OF THE BUILDING CODE & DEPT OF... $4,000 $0 Oct 4, 2012
Dec 15, 2011 36018140L RESOLVE CLASS - 2 FAILURE TO FILE AN ACCEPTABLE 6TH ROUND TECHNICAL REPORT IN COMPLIANCEWITH CODE PROVISIONS: PERIODIC INSPECTION OF EX... $2,000 $0 Apr 26, 2012
Mar 15, 2011 36016395Y RESOLVE CLASS - 2 FAILURE TO FILE AN ACCEPTABLE SIXTH ROUND TECHNICAL REPORT IN COMPLIANCE W/ CODE PROVISIONS PERIODIC INSP OF EXTERIOR... $2,000 $0 May 19, 2011
Apr 28, 2010 36013029K RESOLVE CLASS - 2 FAILURE TO FILE AN ACCEPTABLE 6TH ROUND TECHNICAL REPORT IN COMPLIANCEW/CODE PROVISIONS: PERIODIC INSPECTION OF EXTER... $8,000 $0 Jul 8, 2010
Nov 28, 2008 36006306Y RESOLVE CLASS - 2 FAILURE TO SUBMIT AN ACCEPTABLE SIXTH ROUND TECHNICAL REPORT IN COMPLIANCE W/CODE PROVISIONS:PERIODIC INSPECTION OF E... $4,000 $0 Apr 8, 2010
Apr 3, 2003 38137278Z RESOLVE Non-Hazardous 70B15. $0 $0 May 22, 2003
Nov 24, 2001 34294451R RESOLVE Non-Hazardous OPERATION OF A PLACE OF ASSEMBLY ON SECOND FL WHEN DEPT RECORDS DO ROT PROVIDE FOR OPERATION OF A PLACE OF ASSEMBLY. ... $0 $0 Jan 31, 2002
Aug 31, 2001 34294418P RESOLVE Non-Hazardous OPERATION OF A PLACE OF ASSEMBLT ON THE SECOND FLOOR WHEN DEPT RECORDS DO ROT PROVIDE FOR OPERATION OF A PLACE OF ASS... $0 $0 Oct 11, 2001
Aug 31, 2001 34294419R RESOLVE Hazardous WORK W/O A PERMIT. WORK ROTED ON SECOND FLOOR CONVERTION OF FACTORY SPACE TO GAMBLING EST WITH FULL PARTITION WALLS C... $0 $0 Oct 11, 2001
Jul 15, 1996 38057137P RESOLVE Hazardous 22M, CEASE USE UNTILL ITEM 22M- IS COMPLED WITH CALL 212-312-8740 FOR INSPECTION. $1,000 $0 Sep 5, 1996
Jan 21, 1996 38053728Z RESOLVE Non-Hazardous 46T,36W. CEASE USE UNTIL SUCH TIME ALL REPAIRS FOR COMPLETE OPERATION ARE COMPLETED AND TESTED BY INSPECTOR OF THE DE... $200 $0 Mar 14, 1996
Jan 20, 1996 38053727R RESOLVE Non-Hazardous 18X,15M,36W,22M,11Q,03T,46U,53M.18-X-11 ALL INTERLOCKS INOPERATIVE CEASE USE 15M07 PROVIDE MISSING BASEMENT HOISTWAY ... $500 $0 Mar 7, 1996
Jan 17, 1991 38004497J RESOLVE Non-Hazardous 14M,73O,35R,40T,50Y,21L. #35 PROVIDE ACCESS & LEAVE KEY ON PREMISES. #74 PROVIDE ELEV. CO. MOTOR ROOM. #40 TAG GOV. 5... $0 $0 Apr 11, 1991
Jan 12, 1991 38004496H RESOLVE Non-Hazardous 14M,73O,35P,40T. #35 PROVIDE ACCESS. #74 PROVIDE ELEV. CO. NAME IN MOTOR RM. #40 5YR. TAG. #74(A) PROVIDE CAB CAPACIT... $0 $0 Apr 11, 1991