ECB violations
1260-1268 Broadway, Manhattan • Block 00834 • Lot 0011
102 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Oct 11, 2013 | 35029799R | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER DEFECT. REAR EXIT DOOR AT 1 STORY OBSTRUCTED WITH RESTAURANT IT... | $2,500 | $0 | Dec 5, 2013 |
| Dec 27, 2012 | 35001603L | RESOLVE | CLASS - 1 | FAILURE TO TAKE REQUIRED PROTECTIVE MEASURES TO SECURE PUBLIC SAFETY FROM UNSAFE FACADES.NOTED:AT FACADE AND STREET E... | $2,400 | $0 | Mar 7, 2013 |
| Jun 3, 2010 | 34835715K | RESOLVE | CLASS - 2 | FAILURE TO PROVIDE APPROVED/ACCEPTED PLANS AT JOB SITE AT TIME OF INSPECTION. NOTED: NO APPROVED PLANS AT SITE AT TIM... | $0 | $0 | Jul 29, 2010 |
| Jan 27, 2010 | 36011779K | RESOLVE | CLASS - 2 | FAILURE TO FILE AN ARCHITECT / ENGINEER REPORT CERTIFYING EXIT / DIRECTIONAL SIGNS ARE CONNECTED TO EMERGENCY POWER S... | $400 | $0 | Aug 12, 2010 |
| Jul 31, 2009 | 34787869J | RESOLVE | CLASS - 2 | SEC. 3314.9 SCAFFOLD DOES NOT MEET BUILDING CODE STANDARDS. NOTED: SUPPORTED SCAFFOLDS INSTALLED ON ROOF LEVEL AT EXP... | $4,000 | $0 | Aug 18, 2011 |
| Jul 31, 2009 | 34787868H | RESOLVE | CLASS - 2 | WORK CONTRARY TO D.O.B. APPROVED PLANS & APPLICATIONS. NOTED: OUTRIGGER BEAMS TIEBACKS ATTACHED TO WATER TANK BEAMS I... | $0 | $0 | May 12, 2011 |
| Jul 31, 2009 | 34787867X | RESOLVE | CLASS - 2 | FAILED TO NOTIFY DEPT/OBTAIN PERMIT PRIOR TO USE/INST MATERIAL HOIST. NOTED: NO NOTIFICATION FOR MATERIAL HOIST INSTA... | $400 | $0 | May 12, 2011 |
| Jul 15, 2008 | 34683575H | ACTIVE | CLASS - 1 | FAILURE TO MAINTAIN EXTERIOR OF BLDG EAST ELEVATION SHOWS EXTENSIVE CRACKS. IN PARAPET BULGING & PULLING AWAY; STEP C... | $1,000 | $0 | Dec 4, 2008 |
| Feb 2, 2006 | 34509670M | RESOLVE | Non-Hazardous | NOTED: FAILURE TO POST CONTRACTOR'S SIGN. REMEDY: PROVIDE CONTRACTOR'SSIGN. | $0 | $0 | Apr 6, 2006 |
| Sep 1, 2005 | 34405806X | RESOLVE | Non-Hazardous | FAILURE TO POST PERMIT HOLDER SIGN AS REQUIRED BY THE ADMIN CODE NO PERMIT HOLDER SIGN WAS OBSERVED FOR THE SIDEWALK ... | $400 | $0 | Dec 8, 2005 |
| Apr 6, 2005 | 34465199H | RESOLVE | Non-Hazardous | OCCUPANCY CONTRARY TO THAT ALLOWED BY THE CERTIFICATE OF OCCUPANCY #69565. LEGAL OCCUPANCY IN THE CELLAR 2 BOILER,STO... | $0 | $0 | May 26, 2005 |
| Jan 24, 2005 | 34461048M | RESOLVE | Non-Hazardous | FAILURE TO FILE AN AMENDED FIFTH ROUND REPORT ACCEPTABLE TO THIS DEPARTMENT INDICATING CORRECTION OF UNSAFE CONDITION... | $350 | $0 | Apr 7, 2005 |
| Jun 26, 2003 | 34400442L | RESOLVE | Hazardous | FAILURE TO MAINTAIN EXTERIOR BUILDING WALL. NOTED: NORTH ELEVATION FACADE WITH VERTICAL CRACKS IN BRICK WORK, APPROX ... | $0 | $0 | Sep 25, 2003 |
| Apr 30, 2003 | 34400382Z | RESOLVE | Hazardous | FAILURE TO MAINTAIN EXTERIOR BUILDING WALL NOTED:SEPARATING BRICKWORK AT NORTHEAST CORNER OF EAST ELEVATION WITH DISL... | $0 | $0 | Sep 25, 2003 |
| Nov 26, 2002 | 34336656N | RESOLVE | Hazardous | FAILURE TO PROVIDE ADEQUITIE PROTECTION FOR SIDEWALK AND WALKWAYS DURING CONSTRUCTION IMPROPERLY SECURED NEITING @SCA... | $1,000 | $0 | Feb 13, 2003 |
| Jul 23, 2002 | 34340851K | RESOLVE | Non-Hazardous | WORK W/O A PERMIT : EXPIRED PERMIT. NOTED : SIDEWALK SHED ERECTTED AT NORTH ELEVATION UNDER PERMIT 102503649 WHICH EX... | $0 | $0 | Sep 26, 2002 |
| Nov 28, 2001 | 34295360X | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN EXTERIOR BUILDING WALL. NOTED : CRACKED & BULGED TERRACOTTA & BRICK WORK WITH DISPLACED & DISLODG... | $2,000 | $0 | Feb 21, 2002 |
| Oct 12, 2001 | 34258319L | RESOLVE | Hazardous | FAILURE TO MAINTAIN EXTERIOR BUILDING WALL. NOTED : NORTH ELEVATION HAS MANY CRACKS IN TERRA COTTA & BRICK WORK ; BUL... | $2,000 | $0 | Feb 21, 2002 |
| Jul 9, 2001 | 34263231N | RESOLVE | Hazardous | FAILURE TO MAINTAIN EXTERIOR BUILDING WALL.THE MASONRY FASCIA AT THE 11TH & 12TH FLOOR,NORTH ELEVATION,EAST WINDOW LI... | $800 | $0 | Aug 23, 2001 |
| Sep 27, 1999 | 34228115M | ACTIVE | Non-Hazardous | FAILURE TO POST APPROVAL CAPACITY SIGN NOTED:AT 2ND FL. BALLROOM B &C (DIVIDED BY MOVEABLE WALL) APPROX. 50' X50' WIT... | $40 | $0 | Nov 18, 1999 |
| Jul 21, 1999 | 38088640Y | RESOLVE | Non-Hazardous | 74R, FILE FOR DISMANTLE PER CODE. | $0 | $0 | Sep 9, 1999 |
| Jul 21, 1999 | 38087650N | RESOLVE | Non-Hazardous | 74R, FILE FOR DISMANTLE PER CODE. | $350 | $0 | Oct 25, 2001 |
| Jul 21, 1999 | 38088639R | RESOLVE | Non-Hazardous | 74R, FILE FOR DISMANTLE PER CODE. | $350 | $0 | Oct 25, 2001 |
| Feb 22, 1999 | 38085009Z | RESOLVE | Non-Hazardous | 73M5. -73 DEVICE REMOVED WITHOUT PERMIT - APPLY TO THIS DEPT FOR PERMIT | $500 | $0 | Apr 15, 1999 |
| Feb 22, 1999 | 38085010X | RESOLVE | Non-Hazardous | 73M5. -73 DEVICE WAS REMOVED WITHOUT PERMIT. APPLY TO THIS DEPT FOR PERMIT | $500 | $0 | Apr 15, 1999 |
| Feb 22, 1999 | 38085011H | RESOLVE | Non-Hazardous | 73M5. -73 DEVICE WAS REMOVED WITHOUT PERMIT. APPLY TO THIS DEPT FOR PERMIT | $0 | $0 | Apr 9, 1999 |
| Jan 28, 1999 | 34195091Z | RESOLVE | Non-Hazardous | OCCUPANCY CONTRARY TO BLDG DEPT REC. NOTED;RESTURANT OPERATING ON FIRST FL. "JANANEESE KOREAN RESTURANT" REMEDY:DISCO... | $800 | -$400 | Mar 18, 1999 |
| Oct 21, 1998 | 38080979R | RESOLVE | Non-Hazardous | 50H 50# MAIN MACHINE BEARING & WORN | $0 | $0 | Dec 10, 1998 |
| Oct 8, 1998 | 34186594X | RESOLVE | Non-Hazardous | FAILURE TO PROVIDE APPROVED PLANS AT PREMISES AT TIME OF INSPECTION. NOTED: NO APPROVED PLANS ALT #1P001491. CONSTRUC... | $0 | $0 | Dec 3, 1998 |
| Aug 10, 1997 | 34142291Y | RESOLVE | Hazardous | SIDEWALK SHED NOT ADEQUATELY MAINTAINED-APPROX 24' OF PLYWOOD SIDE ENCLOSING MISSING AT FRONT ENTRANCE TO THE ABOVE S... | $1,000 | $0 | Aug 27, 1998 |
| Aug 7, 1997 | 34150758Z | RESOLVE | Hazardous | FAILURE TO FILE AN AMENDED ROUND FOUR REPORT ACCEPTABLE TO THIS DEPT PURSUANT TO RULE R.C.N.Y.32-03B(5), INDICATING C... | $1,000 | $0 | Nov 13, 1997 |
| Jun 25, 1997 | 34154620Y | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN DIDNG CONSTRUCTION OPERATION. A 3'X 3'X 3' METAL SECTION OF METAL FRAMING USE FOR SCAFFOLDING HAS... | $800 | $0 | Aug 14, 1997 |
| May 30, 1997 | 34150863K | RESOLVE | Hazardous | FAILURE TO FILE AN AMENDED ROUND FOUR REPORT ACCEPTABLE TO THIS DEPARTMENT PURSUANT TO RULE R.C.N.Y. 32- 03B(50 INDIC... | $500 | $0 | Jul 31, 1997 |
| Apr 30, 1997 | 38059239P | RESOLVE | Hazardous | 40 M 47 M VIOLATION IS FOR USING ROPED CAR SEEING AS WORKING PLATFORM FOR WORKMEN WITHOUT A GOVERNOR OR GOVERMETN CAB... | $0 | $0 | Jul 31, 1997 |
| Apr 30, 1997 | 38059243H | RESOLVE | Hazardous | 40 M 47 M VIOLATION IS FOR USING ROPED ELEVATOR AS WORKING PLATFORM FOR WORKMEN WITHOUT A GOVERNOR OR GOVERNOR CABLE ... | $0 | $0 | Jul 31, 1997 |
| Apr 30, 1997 | 38059244J | RESOLVE | Hazardous | REMOVE 2 SPACES DEVICE FROM DOOR 7 GATE CIRCUITS | $0 | $0 | Jul 31, 1997 |
| Apr 30, 1997 | 38059241Y | RESOLVE | Hazardous | 40 M 47 M VIOLATION IS FOR USING ROPED ELEVATOR AS WORKING PLATFORM FOR WORKMEN WITHOUT A GOVERNOR OR GOVERNOR CABLE ... | $0 | $0 | Jul 31, 1997 |
| Apr 30, 1997 | 38059242X | RESOLVE | Hazardous | 40 M 47 M VIOLATION IS FOR USING ROPED ELEVATOR AS WORKING PLATFORM FOR WORKMEN WITHOUT A GOVERNOR OR GOVERNOR CALBE.... | $0 | $0 | Jul 31, 1997 |
| Apr 30, 1997 | 38059240M | RESOLVE | Hazardous | 40 M 47 M VIOLATION IS FOR USING ROPED CAR AS WORKING PLATFORM FOR WORKMEN WITHOUT A GOVERNOR OR GOVERNOR CABLE. CEAS... | $0 | $0 | Jul 31, 1997 |
| Mar 13, 1997 | 34136806N | RESOLVE | Non-Hazardous | WORK WITHOUT A PERMIT NOTED PERMIT NO 1 P0001491-01 EXPIRED ON 1-18-97 A REVIEW OF BUILDING DEPT RECORDS INICATE THAT... | $0 | $0 | May 29, 1997 |
| Mar 5, 1997 | 34136773X | RESOLVE | Hazardous | RAILS BUT ON 03-05-97 NO EFFOR WAS MADE TO SAFEGUARD REMEDYR AND 1ST FLOOR TO BASEMENT NOT PROTECTED BY A GURAD RAIL ... | $1,000 | $0 | May 22, 1997 |
| Jan 12, 1995 | 34118901M | RESOLVE | Non-Hazardous | WORK WITHOUT PERMIT.NOTED.A HEAVY DUTY SIDEWALK SHED HAS BEEN ERECTED-APPOX. 80 FEET ON BROADWAY SIDE&100FT. ON W 32 ... | $0 | $0 | Mar 2, 1995 |
| Jan 12, 1995 | 34118831X | RESOLVE | Non-Hazardous | WORK WITHOUT A PERMIT:WORK NOTE:SIDE WALK SHED LOCATION:BROADWAY AND ON 32 STREET REMEDY.OBTAIN A PERMIT. | $0 | $0 | Mar 2, 1995 |
| Sep 26, 1994 | 34115635P | RESOLVE | Non-Hazardous | WORK WITHOUT A PERMIT WORK NOTE ERECTEN SIDEWALK SHED ON WEST 33 RD ST. &BROADWAY . REMENDY:OBTAIN PERMIT. | $0 | $0 | Dec 8, 1994 |
| Feb 5, 1994 | 34093472P | RESOLVE | Hazardous | FAILURE TO MAINTAIN EXTERIOR BLDG WALL. DEFECT IS. STONE LEDGE BETWEEN 13 & 14 FLOOR AT THE CORNER OF 32 & BWY. APPRO... | $800 | $0 | Apr 28, 1994 |
| May 2, 1990 | 34042479H | RESOLVE | Non-Hazardous | FAILURE TO OBTAIN A SIGN-OFF FOR BN 223/84 REMEDY: OBTAIN A SIGN-OFF FOR BN 223/84 | $0 | $0 | Jun 14, 1990 |
| Dec 15, 1989 | 34034551N | RESOLVE | Unknown | WORK CONTRARY TO APPROVED PLANS. REMEDY: STOP ALL WORK. CONFORM TO APPROVED SPEC SHEET. | $50 | $0 | Feb 22, 1990 |
| Nov 30, 1989 | 34034455N | RESOLVE | Non-Hazardous | WORK WITHOUT A PERMIT NOITED INSTALLATION OF A CONSTRUCTION HOIST FROMGROUND LEVEL OF ROOF 17 STORIES. LOCATION CENTE... | $250 | $0 | Jan 11, 1990 |
| Sep 5, 1989 | 34029034Z | RESOLVE | Non-Hazardous | OPERATING A PA WITHOUT A CURRNET PERMIT REMEDY OBTAIN A CURRENT PERMIT BNH 223/84 NOT SIGNED OFF REMEDY HAVE BN # 223... | $125 | $0 | Dec 7, 1989 |
| Apr 5, 1989 | 34018659P | ACTIVE | Unknown | OPERATION OF PA WITHOUT A CURRENT PERMIT REMEDY OBTAIN A PERMIT BN223/84 NOT SIGNED OFF REMEDY HAVE BN 223/84 SIGNED OFF | $375 | $0 | May 18, 1989 |