Issued Violation Status Severity Description Penalty Balance due Hearing
Sep 23, 2025 39161356L RESOLVE CLASS - 1 A8: ELECTRICAL WORK WITHOUT A PERMIT. FOR THE INSTALLATION OF 20 JOCO CHARGING STATION, 8 OUTLETS & GENERAL WIRING IN... $800 $0 Jun 22, 2026
Nov 21, 2023 39523562H RESOLVE CLASS - 1 I RESPOND TO AN INCIDENT THAT OCCURRED ON 10-19-2023 ON THIS JOBSITE WHERE A WORKER FELL OFF STEP LADDER AND WAS TAKE... $10,000 $10,000 Sep 19, 2025
Nov 15, 2018 38266385P RESOLVE CLASS - 2 99BB15,59BB15. 99-CAT 1 TAG EXPIRED; 59-BRAKE MAINTENANCE TAG EXPIRED $625 $0 May 2, 2019
Dec 28, 2017 35311192J RESOLVE CLASS - 2 VIOLATION OF DISCRETIONARY ZONING CONDITIONS ON PRIVATELY OWNED PUBLICSPACE.AT TIME OF INSPECTION(11.45AM)GATE WAS CL... $0 $0 Nov 15, 2018
Dec 28, 2017 35311193L ACTIVE CLASS - 2 VIOLATION OF DISCRETIONARY ZONING CONDITIONS ON PRIVATELY OWNED PUBLICSPACE.AT TIME OF INSPECTION PUBLIC PLAZA IS MIS... $4,000 $0 Nov 15, 2018
May 22, 2015 35132054H RESOLVE CLASS - 2 PSWO SUSPENDED SCAFFOLD. FAILURE TO PROVIDE SPECIALTY CREW LETTER APPROVEDBY THE DEPARTMENT. NOTED: AT TIME OF INSPEC... $0 $0 Jul 9, 2015
May 22, 2015 35132055J RESOLVE CLASS - 1 3314.15.2 THE HANGER OR STIRRUP SHALL BE PLACED AT LEAST 6" BUT NOT MORE THAN 18" FROM THE END OF THE PLATFORM. NOTED... $1,600 $0 Jul 9, 2015
May 22, 2015 35132053X RESOLVE CLASS - 2 WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS. NOTED: AT TIME OF INSPECTION NO DETAILS COULD BE PROVIDED S... $0 $0 Jul 9, 2015
Sep 30, 2013 35028424X RESOLVE CLASS - 2 SEC. 27-292.1 & BC 1105.1. PEOPLE W/PHYSICAL DISABILITIES: PUBLIC SPACES/ROOMS NOT ACCESSIBLE/USABLE. AT TIME OF INSP... $800 $0 Nov 14, 2013
Jun 11, 2010 34836395P RESOLVE CLASS - 1 BC3314.9 SUPPORTED SCAFFOLD DOES NOT MEET CODE SPECIFICATIONS NOTED PIPE SCAFFOLD ERECTED AT EXP#2 @ SIDE OF PARKING ... $1,600 $0 Feb 3, 2011
Jun 11, 2010 34836396R ACTIVE CLASS - 1 INADEQUATE SAFETY MEASURES OPERATION OF HOISTING EQUIPMENT IN UNSAFE MANNER NOTED ROPE SCAFFOLD SUSPENDED AT EXP#1 AT... $4,800 $0 Feb 3, 2011
Jul 6, 2009 38204465L RESOLVE CLASS - 2 17H11.10H11.69M7.17H11 WHERE AS NEEDED $0 $0 Aug 27, 2009
Jun 1, 2009 38203876L RESOLVE CLASS - 2 05J01 11D06 05J-REDUCED GAP ON CAR DOOR $0 $0 Jul 23, 2009
Oct 25, 2007 38179501H RESOLVE Non-Hazardous 83X10,85BB05. $180 $0 Dec 20, 2007
Oct 25, 2007 38179500X RESOLVE Non-Hazardous 85M05. $180 $0 Dec 20, 2007
Jun 3, 1999 38087681X RESOLVE Non-Hazardous 48H. $0 $0 Jul 22, 1999
Mar 24, 1997 34152117H RESOLVE Non-Hazardous WORK WITHOUT A PERMIT. NOTED OFICE CONSTRUCTED ABOVE KITCHEN ILLEGALLY. 6'X10' OFFICE & STORAGE ERECTED MADE OF PLYWO... $350 $0 Aug 7, 1997
Jul 10, 1991 38013941L RESOLVE Non-Hazardous 11B; $0 $0 Aug 22, 1991
Jul 10, 1991 38013943P RESOLVE Non-Hazardous 73X; RESTORE TO SERVICE. $0 $0 Aug 22, 1991
Jul 10, 1991 38013945Z RESOLVE Non-Hazardous 11B; $0 $0 Aug 22, 1991
Jul 10, 1991 38013944R RESOLVE Non-Hazardous 73X; RESTORE TO SERVICE. $0 $0 Aug 22, 1991
Jul 10, 1991 38013942N RESOLVE Non-Hazardous 11B; $0 $0 Aug 22, 1991