Skip to content

ECB violations

11 East 31 Street, Manhattan • Block 00861 • Lot 0010

41 records

Environmental Control Board violations, which carry a hearing and a penalty.

Issued Violation Status Severity Description Penalty Balance due Hearing
Mar 3, 2016 35141630L RESOLVE CLASS - 2 FAIL TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER RE: INSTALLATION/MAINTENANCE OF PLUMBING MATERIAL/EQUIPMENT PER PC... $0 $0 Apr 21, 2016
Aug 12, 2015 35145235J RESOLVE CLASS - 1 FAILURE TO SAFEGUARD ALL PERSONS AND PROPERTY AFFECTED BY CONSTRUCTION@ THE 29 FLOOR OBSERVED MAN WORKING ON LEADING ... $2,400 $0 Oct 1, 2015
Aug 12, 2015 35145237N RESOLVE CLASS - 2 SIDEWALK SHED DOES NOT MEET CODE SPECIFICATIONS.NOTE:30 STORY BLDG UNDER CONSTRUCTION.@ EXP.#1 THE SIDEWALK SHED WIRI... $2,400 $0 Oct 1, 2015
Aug 12, 2015 35145236L RESOLVE CLASS - 1 FAILURE TO MAINTAIN:NO HANDRAILS.NOTE:30 STORY BLDG UNDER CONSTRUCTION OBSERVED IN STAIRCASE A+B FROM FLOORS 21-14 TH... $1,000 $0 Oct 1, 2015
May 23, 2015 35043599N RESOLVE CLASS - 2 FAILURE TO COMPLY W/THE COMM'S ORDER TO FILE C OF C W/THE DOB'S FOR NOTICE OF VIO #35153697Y ISSUED ON 4/2/15 PURSUAN... $400 $0 Jul 9, 2015
May 15, 2015 35043327J RESOLVE CLASS - 2 FAILURE TO COMPLY W/COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION W/DOB FOR NOV #35153698X ISSUED ON 3/27/... $400 $0 Jul 2, 2015
May 12, 2015 35130910M RESOLVE CLASS - 1 3308.1.3 HORIZONTAL SAFETY NOT PROVIDED DURING NEW CONSTRUCTION CONCRETE BUILDING.@ TIME OF INPSECTION ACTIVE CONSTRU... $1,600 $0 Jul 2, 2015
May 12, 2015 35130913H RESOLVE CLASS - 1 3301.2. HOLES/OPENING NOT COVERED @ TIME OF INSP.ACTIVE CONSTRUCTION SITE.OBSERVED HOLE OPENING 2"TO 18"ON VARIOUS FL... $1,600 $0 Jul 2, 2015
May 12, 2015 35130911Y RESOLVE CLASS - 2 FAILURE TO MAINTAIN ALTERNATE HOUSEKEEPING PER SECTION REQUIREMENT AT TIME OF INSPECTION ACTIVE CONSTRUCTION SITE CON... $0 $0 Jul 2, 2015
May 12, 2015 35130912X RESOLVE CLASS - 1 FAILURE TO INSTITUTE MAINTAIN SAFETY EQUIPMENT MEASURES OR TEMP.CONSTRUCTION TOE BOARDS.NOTE ACTIVE CONSTRUCTION SITE... $1,000 $0 Jul 2, 2015
Apr 2, 2015 35153697Y RESOLVE CLASS - 1 MC801.1.1.1,FAILURE TO EXTEND ADJOINING CHIMNEY OF BLDG @ 15 WEST 31 STREET AS PER CODE.NOTE:EXISTING BRCIK CHIMNEY N... $1,630 $0 May 21, 2015
Mar 27, 2015 35153698X RESOLVE CLASS - 1 FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY.DEFECT NOTED:@ REAR OF15 E 31 STREET.(1)BLOCKING 1ST FL FIRE ESCAPE @... $1,000 $0 Jun 25, 2015
Feb 25, 2015 35122282K RESOLVE CLASS - 2 WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS &/OR APPROVEDAMENDMENTS. AT TIME OF INSPECTION OBSERVED ACTI... $0 $0 Apr 16, 2015
Feb 11, 2015 35121123Z RESOLVE CLASS - 1 BC3314.4.3 NO RECORD OF DAILY INSPECTION OF SUPPORTED SCAFFOLD PERFORMED BY COMPETENT PERSON AT SITE NOTED: SIDEWALK ... $1,600 $0 Jun 18, 2015
Feb 11, 2015 35121122R RESOLVE CLASS - 1 WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS-SITE SAFETY PLAN.NOTED: FIRE ESCAPE OF ADJACENT PROEPRTY AT ... $1,000 $0 Jun 18, 2015
Feb 11, 2015 35121124K RESOLVE CLASS - 2 28-110.1 OSHA 10 NOTED: SITE SAFETY MANAGER VADIM LEYKIN #1863 DOES NOT HAVE OSHA CARD ON HIM (NOT EVEN A COPY). RMDY... $0 $0 Apr 2, 2015
Feb 3, 2015 35121132K RESOLVE CLASS - 1 FAILURE TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS. AT TIME OF INSPECTION OBSERVED ACTIV... $2,400 $0 May 28, 2015
Feb 3, 2015 35121131Z RESOLVE CLASS - 1 SEC. 3303.6 ESCAPE HATCHES: NOT PROVIDED. AT TIME OF INSPECTION OBSERVED ACTIVE JOBSITE. OBSERVED AT THE 2ND FL(MEZZ)... $1,600 $0 May 28, 2015
Feb 3, 2015 35121133M RESOLVE CLASS - 1 SEC. 3301.1.2 FAILURE TO COMPLY W/NYC FIRE CODE - GENERAL NO FIRE WATCH,FIRE GUARD. CERTIFICATE OF FITNESS. AT TIME O... $1,600 $0 May 28, 2015
Nov 24, 2014 35110463L RESOLVE CLASS - 1 WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENT - SOE PLAN OBSERVED 3 WORKERS IN A PIT;WORKER CUTTING CAISSON... $1,000 $0 Apr 16, 2015
Nov 20, 2014 35109567H RESOLVE CLASS - 1 3317.1 GENERAL.ALL (H ),TRANSPORTING,STORAGE INSTALLATION CONNECTION (V )FLAMMABLE AND COMBUSTIBLE MIXTURES.NOTE:MEN ... $1,600 $0 Apr 16, 2015
Nov 20, 2014 35109566X RESOLVE CLASS - 1 3310.6 DESIGNATED CONCRETE SITE SAFETY MANAGER.NOTE:ACTIVE CONCRETE JOB IN PROG,SUBCELLAR FORMED.MEN ( )EXCAVATOR MOV... $400 $0 Apr 16, 2015
Nov 5, 2014 35110417K RESOLVE CLASS - 1 CONTRARY TO PLANS, NOTEICE AT TIME OF INSPEC.NB IN PROGRESS.SITE SAFETY PLAN SHOWS FULLY ENCLOSED BARRICADED WALKWAY ... $1,000 $0 Apr 16, 2015
Nov 5, 2014 35110418M RESOLVE CLASS - 1 3303.15MISC.VIO.CONCRETE WASHOUT WATER SHALL NOT BE ALLOWED TO ENTER ANY SEWER,CATCH BASIN,VAULT, DRAIN OR BODY OF WA... $400 $0 Apr 16, 2015
Nov 5, 2014 35110416Z RESOLVE CLASS - 1 3303.15.1MIS.VIO.COLLECTION & CONTAINMENT NOTICED AT TIE OF INSPEC. NB IN ROGRESS POURING FOUNDATIONS NOTICED CONCRET... $400 $0 Apr 16, 2015
Nov 5, 2014 35110415R RESOLVE CLASS - 2 3310.8.3MIS.VIO. NO LOG BOOKS FOR CONCRETE PUMP @ TIME OF INSPEC.NO IN PROGRESS FOUNDATION WORK CONCRETE PUMP IN USE ... $0 $0 Jan 8, 2015
Sep 29, 2014 35098903R RESOLVE CLASS - 1 28-110.1 OSHA 10.NOTICED @ TIME OF INSP.NB IN PROGRESS FOUNDATION & EXCAVCATION WORK ON GOING NOTICE 3 WORKERS WORKIN... $1,600 $0 Dec 18, 2014
Sep 29, 2014 35098902P RESOLVE CLASS - 1 28-110.1 SSM SHALL PROVIDE A STATEMENT THAT ALL WORKERS EMPLOYED ON S ITE WILL SECURE A SITE SPECIFIC ORIENTATION PRO... $400 $0 Dec 18, 2014
Aug 19, 2014 35099047H RESOLVE CLASS - 2 SEC. 3301.1.2 FAILURE TO COMPLY W/NYC FIRE CODE. NO PERMIT FOR OXYGEN & ACELYLENE STORED AT SITE. AT TIME OF INSPECTI... $0 $0 Oct 9, 2014
Aug 19, 2014 35099046X RESOLVE CLASS - 2 ELECTRICAL WORK W/O A PERMIT. NOTE AT TIME OF INSPECTION NEW BLDG UNDER CONSTRUCTION PERMIT #12132591 EXCAVATION PHAS... $0 $0 Oct 9, 2014
Jun 10, 2014 35089120X RESOLVE CLASS - 1 3307.4.3 FAILURE TO HAVE YODUCK BARRICADES FILL W/WATER OR SAND AS REQUIRED BY MANUFACTUE.@ TIME OF INSP CONST OPS WO... $8,000 $0 Jul 31, 2014
Oct 1, 2013 35065221Z RESOLVE CLASS - 2 JOB SITE FENCE NOT CONSTRUCTED OR MAINTAINED PURSUANT TO SUBSECTION. NOTED: CONSTRUCTION SITE FENCE ERECTED UNDER PER... $400 $0 Nov 21, 2013
May 1, 2013 35015719K RESOLVE CLASS - 2 SEC. 3310.3 FAILURE TO PROVIDE SITE SAFETY PLAN & PROGRAM AS REQUIRE -AT TIME OF INSPECTION,OBSERVED JOB SITE IN OPER... $0 $0 Jun 20, 2013
May 1, 2013 35015720H RESOLVE CLASS - 1 FAILURE TO PROVIDE SITE SAFETY MANAGER. AT TIME OF INSPECTION,OBSERVEDJOB SITE IN OPERATIONS - WORKERS ON SITE - EXCA... $2,400 $0 Jun 20, 2013
Apr 24, 2013 35012586M RESOLVE CLASS - 2 FAILURE TO SAFEGUARD ALL PERSONS AND PROPERTY AFFECTED BY CONSTRUCTIONFOUNDATIONS OPERATIONS. AT THE TIME OF MY INSPE... $1,200 $0 Jun 13, 2013
Jan 11, 2008 34627164R RESOLVE Non-Hazardous WORK W/AN EXPIRED PERMIT. NOTE: UPON INSPECTION OF THE ABOVE DEMOLITION SITE DOB RECORDS ARE SHOWING DEMOLITION PERMI... $200 $0 Aug 7, 2008
Jan 11, 2008 34627166K RESOLVE Non-Hazardous WORK W/O A PERMIT (EXPIRED PERMIT) NOTE UPON INSPECTION OF THE ABOVE DEMOLITION SITE DOB RECORDS ARE SHOWING FENCE PE... $0 $0 Apr 10, 2008
Jan 11, 2008 34627165Z RESOLVE Non-Hazardous WORK W/O A PERMIT (EXPIRED PERMIT). NOTE: UPON INSPECTION OF THE ABOVEDEMOLITION SITE A SIDEWALK SHED IS ERECTED & DO... $200 $0 Aug 7, 2008
Sep 20, 2004 38147042L RESOLVE Non-Hazardous 83X10 83-X-10 REPAIR SO THAT A PROPER INSPECTION CAN BE MADE BY THIS DEPARTMENT (DOB)212 566 5542 $0 $0 Nov 4, 2004
Mar 7, 2003 38136246J RESOLVE Non-Hazardous 48BB13 $0 $0 Apr 24, 2003
Sep 23, 1997 38064234M RESOLVE Non-Hazardous 22D,25M,48B,49B,50Y,53Y,50O, 25-COVER DOOR OPERATOR 52-REPLACE OIL SOAKED BRAKES $100 $0 Dec 11, 1997