ECB violations
East 39 Street, Manhattan • Block 00868 • Lot 0025
51 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Mar 27, 2026 | 35727053Z | ACTIVE | CLASS - 2 | PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATIONS. AS NOTED: AT TIME OF INSPECTION I OBSERVED DAMAGED AND/OR DE... | $2,400 | $2,400 | Sep 8, 2026 |
| Jan 29, 2025 | 37032716M | ACTIVE | CLASS - 2 | FAILURE TO COMPLY WITH COMMISSIONER'S ORDER CONTAINED IN SUMMONS #35669480K ISSUED ON 11/22/2022, AND FAILURE TO FILE... | $1,250 | $0 | Aug 7, 2025 |
| Jun 17, 2024 | 37028815X | ACTIVE | CLASS - 2 | A.C. 27-929 FAILURE TO COMPLETE INSTALLATION OF FULL SYSTEM OF AUTOMATIC SPRINKLERS & FILE FINAL SPRINKLER REPORT PRE... | $6,250 | $0 | Nov 7, 2024 |
| Feb 28, 2023 | 37025427K | ACTIVE | CLASS - 2 | 27-929.1 FAILURE TO COMPLETE THE INSTALLATION OF A FULL SYSTEM OF AUTOMATIC SPRINKLERS AND FILE A FINAL SPRINKLER REP... | $1,250 | $0 | Jan 18, 2024 |
| Nov 22, 2022 | 35669480K | ACTIVE | CLASS - 2 | FAILURE TO MAINTAIN EXTERIOR FACADE AND APPURTENANCES.FACADE TECHNICALREPORT FILED AS UNSAFE BY QEWI ON 11/14/2022.RE... | $1,250 | $0 | Mar 2, 2023 |
| Nov 1, 2021 | 37022516Z | ACTIVE | CLASS - 2 | 27-929.1 AC27-929.1,FAILURE TO COMPLETE INSTALLATION OF FULL SYSTEM OFAUTOMATIC SPRINKLERS&FILE FINAL SPRINKLER REPOR... | $3,125 | $0 | Mar 17, 2022 |
| Nov 18, 2020 | 39032203J | RESOLVE | CLASS - 3 | WORK WITHOUT A PERMIT. AT TIME OF INSPECTION, OBSERVED CONSTRUCTION FENCE ERECTED AT EXPOSURES #1 , #2 OF THE COMMERC... | $0 | $0 | Aug 12, 2021 |
| Nov 18, 2020 | 39032202H | RESOLVE | CLASS - 2 | JOBSITE FENCE NOT CONSTRUCTED OR MAINTAINED PURSUANT TO SUBSECTION. AT TIME OF INSPECTION, OBSERVED CONSTRUCTION FENC... | $0 | $0 | Aug 12, 2021 |
| Jul 13, 2020 | 37019808N | ACTIVE | CLASS - 2 | SEC. AC 27-929.1 FAILURE TO COMPLETE THE INSTALLATION OF A FULL SYSTEMOF AUTOMATIC SPRIKLERS & FILE A FINAL SPRINKLER... | $3,125 | $0 | Jul 8, 2021 |
| Nov 15, 2019 | 37016380H | ACTIVE | CLASS - 2 | SEC. A.C.27-929.1,FAILURE TO COMPLETE THE INSTALLATION OF A FULL SYSTEM OF AUTOMATIC SPRINKLERS & FILE A FINAL SPRINK... | $1,250 | $0 | May 14, 2020 |
| May 31, 2016 | 35116866N | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS. CN15 3/18 CD 4061 MR195 WHILE ATTEMP... | $0 | $0 | Nov 15, 2019 |
| Feb 26, 2016 | 35155226R | RESOLVE | CLASS - 1 | 3301.8.1 USE AND TAMPERING OF EQUIPMENT INVOLVED IN AN ACCIENT IS PROHIBITED. ON MAY 31,2015,THERE WAS AN ACCIENT AT ... | $0 | $0 | Nov 15, 2019 |
| May 31, 2015 | 35116865L | RESOLVE | CLASS - 1 | MASTER RIGGER FAILED TO FOLLOW MANUFACTURERS RECOMMENDATION. ON 5/31/15 THERE WAS AN ACCIDENT @ 261 MADISON AVE MN IN... | $0 | $0 | Nov 15, 2019 |
| May 31, 2015 | 35116864J | RESOLVE | CLASS - 1 | SEC: 1RCNY 104-20(E). MASTER RIGGER FAILED TO BE ON SITE DURING CRITICAL PICK. ON 5/31/15 THERE WAS AN ACCIDENT @ 261... | $0 | $0 | Nov 15, 2019 |
| May 31, 2015 | 35116863H | RESOLVE | CLASS - 1 | SEC: 3320.3.1. IMPROPERLY MARKED OR NON-IDENTIFIED HOISTING EQUIPMENT.ABOVE MASTER RIGGER ON JOB CN 153/15 CD 4061 MR... | $8,000 | $0 | Sep 19, 2019 |
| May 31, 2015 | 35116862X | RESOLVE | CLASS - 1 | INADEQUATE SAFETY MEASURES USE OF HOISTING EQUIPMENT IN AN UNSAFE MANNER. CN 153/15 CD 4061 MR 195 ON 5/31/2015 WHILE... | $24,000 | $0 | Sep 19, 2019 |
| Oct 30, 2013 | 35031131J | RESOLVE | CLASS - 1 | SEC. 9-01 RIGGER FAILED TO DESIGNATE A "FOREMAN". NOTED: AT TIME OF INSPECTION,MR MANUEL FERNANDES WAS IN PROCESSION ... | $400 | $0 | Dec 19, 2013 |
| Oct 30, 2013 | 35031132L | RESOLVE | CLASS - 2 | WORK DOES NOT CONFORM TO APPROVED/ACCEPTED PLANS. NOTED: INSTALLATION OF CONSTRUCTION FENCE AT EXPOSURES #1,#2,#4 ARE... | $0 | $0 | Dec 19, 2013 |
| Oct 30, 2013 | 35031130H | RESOLVE | CLASS - 1 | SEC. 3310.3 FAILURE TO HAVE SITE SAFETY PLAN & PROGRAM AS REQUIRED. NOTED: NO SITE SAFETY PROGRAM IN PLACE,JOB SITE H... | $1,600 | $0 | Jan 16, 2014 |
| Jan 27, 2010 | 36011831Z | RESOLVE | CLASS - 2 | FAILURE TO FILE AN ARCHITECT / ENGINEER REPORT CERTIFYING EXIT / DIRECTIONAL SIGNS ARE CONNECTED TO EMERGENCY POWER S... | $4,000 | $0 | Aug 26, 2010 |
| Apr 10, 2009 | 34783869L | RESOLVE | CLASS - 1 | OUTDOOR ADVERTISING COMPANY SIGN PROHIBITED IN C5-2 DISTRICT. (FUERZA BRUTA) REM: REMOVE ILLEGAL SIGN. | $0 | $0 | Mar 2, 2010 |
| Sep 25, 2008 | 36000060X | RESOLVE | CLASS - 1 | FAILURE TO FILE AFFIDAVITS AND/OR COMPLY WITH OTHER REQUIREMENTS SET FORTH FOR PHOTOLUMINESCENT EXIT PATH MARKING. RE... | $0 | $0 | Jan 8, 2009 |
| Jan 4, 2008 | 38180826Y | RESOLVE | Non-Hazardous | 16M0759L10. (16M07) PROVIDE SIGHT ON ALL HOIST WAY DOORS (59L10) REPAIR ALL MOTOR ROOM LIGHTS. | $350 | $0 | Feb 28, 2008 |
| Jun 12, 2007 | 38167457L | RESOLVE | Non-Hazardous | 86M07. (86-M-07) 2 YR TEST. | $0 | $0 | Aug 9, 2007 |
| Jun 12, 2007 | 38167456J | RESOLVE | Non-Hazardous | 86M07. (86-M-07) 2 YR TEST. | $180 | $0 | Aug 9, 2007 |
| Jun 12, 2007 | 38167455H | RESOLVE | Non-Hazardous | CEASE USE. 01X10,03M07. (01-X-10)REPAIR INOPERATIVE STOP SWITCH CAR STATION (03-M-07)PROVIDE MISSING PART OF CEILING ... | $500 | $0 | Aug 9, 2007 |
| Oct 4, 2006 | 38161686H | RESOLVE | Non-Hazardous | 51B14/73H11. 51-B-14-SHORTEN HOIST ROPES. 73-H-11-WORN COMPESATION ROPES | $0 | $0 | Nov 16, 2006 |
| Jun 17, 2005 | 34458792N | RESOLVE | Non-Hazardous | FAILURE TO SUBMIT A FIFTH ROUND TECHNICAL REPORT IN COMPLIANCE WITH CODE PROVISIONS: PERIODIC INSPECTION OF EXTERIOR ... | $0 | $0 | Sep 1, 2005 |
| Apr 29, 2005 | 34458499Y | RESOLVE | Hazardous | FAILURE TO SUBMIT A FIFTH ROUND TECHNICAL REPORT IN COMPLIANCE WITH CODE PROVISIONS:PERIODIC INSPECTION OF EXTERIOR W... | $0 | $0 | Dec 10, 2012 |
| Nov 12, 2004 | 34462127P | RESOLVE | Non-Hazardous | FAILURE TO SUBMIT A FIFTH ROUND TECHNICAL RPEOR:PERIODIC INSPECTION OFEXTERIOR WALLS WALLS AND APPURTENANCES AS REQUI... | $0 | $0 | Dec 10, 2012 |
| May 19, 2003 | 34384489L | RESOLVE | Non-Hazardous | FAILURE TO SUBMIT A FIFTH ROUND TECHNICAL REPORT: PERIODIC INSPECTION OF EXTERIOR WALLS AND APPURTENANCES AS REQUIRED... | $0 | $0 | Feb 5, 2004 |
| Mar 14, 2003 | 38136417P | RESOLVE | Non-Hazardous | 79X12. RETURN DEVICE TO SERVICE 50 AN INSPECTION CAN BE PERFORMED. | $0 | $0 | Sep 11, 2003 |
| Mar 14, 2003 | 38136416N | RESOLVE | Non-Hazardous | 2M07-12Q03-39I12-37O02-62O02. 62-PRVOIDE SUMP COVER 12-PROVIDE LIGHT GURRDS 39-REPLACE DAMAGED RESISTOR TUBE ON REAR ... | $0 | $0 | May 1, 2003 |
| Mar 14, 2003 | 38136415L | RESOLVE | Non-Hazardous | 70E11. COUNTER WEIGHT BUFFER MAKES CONTACT WITH BRIFFER BOX IN PIT. | $0 | $0 | May 1, 2003 |
| Mar 3, 2003 | 34384373J | RESOLVE | Non-Hazardous | FAILRURE TO SUBMIT A FIFTH ROUND TECHNICAL REPORT:PERIODIC INSPECTION OF EXTERIOR WALLS AND APPURTENANCES AS REQUIRED... | $0 | $0 | Jul 15, 2003 |
| Aug 10, 2002 | 34333426Y | RESOLVE | Non-Hazardous | FAILURE TO CARRY OUT PERMITTED WORK IN ACCORDANCE WITH APPLIACABLE LAWS AND REGULATIONS IN THAT CONSTRUCTION ACTIVITI... | $0 | $0 | Oct 10, 2002 |
| Aug 10, 2002 | 34333428H | RESOLVE | Hazardous | HAZARDOUS-FAILURE TO PROVIDE ADEQUATE PROTECTION FOR SIDEWALKS AND WALKWAYS DURING CONSTRUCTION OPERATIONS. RENOVAL O... | $2,000 | $0 | Oct 10, 2002 |
| Jun 15, 2001 | 38117155K | RESOLVE | Non-Hazardous | 74B7-POST CERTIFICATE IN CAR AS PER RULE 27-1004(A) OR (B) | $2,500 | $0 | Aug 2, 2001 |
| Feb 5, 2001 | 38109530N | RESOLVE | Non-Hazardous | 46K12. 46K12-REPLACE RUSTED & UNDERSIZE HOIST ROPES. | $2,500 | $0 | Mar 22, 2001 |
| Sep 13, 2000 | 38106543Z | RESOLVE | Non-Hazardous | 46K12-HOIST CABLES RUSTED BY UNDERSIZE. | $2,500 | $0 | Dec 7, 2000 |
| Feb 14, 1998 | 38070039H | RESOLVE | Non-Hazardous | 74X,04M,74X-REPAIR COMMUNICATION 04M PROVIDE KEY FOR EXIT. | $350 | $0 | Jun 18, 1998 |
| Feb 14, 1998 | 38070038X | RESOLVE | Non-Hazardous | 74X,04M,74-REPAIR CAR COMMUNICATION 24M PROVIDE KEY FOR EXIT | $350 | $0 | Jun 18, 1998 |
| Feb 14, 1998 | 38070037Y | RESOLVE | Non-Hazardous | 74X,04M,74X-RAIR CAR COMMUNICATION 04M PROVIDE KEY FOR EXIT. | $350 | $0 | Jun 18, 1998 |
| Feb 14, 1998 | 38070036M | RESOLVE | Non-Hazardous | 74X,57M,04M,74XREPAIR CAR COMMUNICATION 57M,PROVIDE LOCK ON PIT DOOR 04M PROVIDE KEY FOR EXIT. | $350 | $0 | Jun 18, 1998 |
| Feb 14, 1998 | 38070035K | RESOLVE | Non-Hazardous | 74X,04M,74XREPAIR COMMUNICATION IN CAR 04M PROVIDE KEY FOR EXIT | $350 | $0 | Jun 18, 1998 |
| Feb 14, 1998 | 38070041R | RESOLVE | Non-Hazardous | 74X,04M,74X-REPAIR COMMUNICATION 04M PROVIDE KEY FOR EXIT | $350 | $0 | Jun 18, 1998 |
| Feb 14, 1998 | 38070042Z | RESOLVE | Non-Hazardous | 74X,04M,74X,-REPAIR COMMUNICATION 04 PROVIDE KEY FOR EXIT | $350 | $0 | Jun 18, 1998 |
| Feb 14, 1998 | 38070040P | RESOLVE | Non-Hazardous | 46K,74X,04M,46K-RENEW HOST ROPES 74X REPAIR COMMUNICATION 04M PROVIDE KEY FOR EXIT | $350 | $0 | Jun 18, 1998 |
| Dec 6, 1995 | 38052975L | RESOLVE | Non-Hazardous | 50I.50-MAIN MACHINE FIELD WINDING HOIST INSTALATION DAMAGE. | $0 | $0 | Mar 7, 1996 |
| Dec 6, 1995 | 38052973H | RESOLVE | Non-Hazardous | 50D,#I,46B.50-MAIIN MACHINE HOIST FIELD WINDING #PLATFORM DAMAGED IN CAR 46 HOIST CABLES. | $0 | $0 | Mar 7, 1996 |