Skip to content

ECB violations

143-147 East 23 Street, Manhattan • Block 00879 • Lot 0027

121 records

Environmental Control Board violations, which carry a hearing and a penalty.

Issued Violation Status Severity Description Penalty Balance due Hearing
Mar 26, 2008 34610382Y RESOLVE Non-Hazardous FAILURE TO MAINTAIN PLUMBING AND/OR APPURTENANCES HAZARDOUS. UPON INSPECTION OF APT 4R WITNESSED TOILET CONSTANTLY RU... $0 $0 Jul 24, 2008
Dec 19, 2007 38179540K RESOLVE Non-Hazardous CEASE USE ITEMS (30N10) 84I10. 30 (AUDIT) SWITCHES JUMPED OUT ON CONTROLLER; REPAIR CEASE USE ITEMS. CALL 212 566-554... $800 $0 Feb 14, 2008
Dec 19, 2007 38179538L RESOLVE Non-Hazardous (70X10) CEASE USE ITEMS (70I11) 70 TAIL ROPE LINKED; REPLACE ALSO TAILROPE PULLED OUT ALL THE WAY DRAIN & SAFETY NOT ... $800 $0 Feb 14, 2008
Dec 19, 2007 38179539N RESOLVE Non-Hazardous 90X10. CEASE USE 70B10. 70 TAIL ROPES PULLED OUT & OFF OF DRAINS & SAFETY NOT ACTIVATED. RESET TAIL ROPE SO IT WILL A... $800 $0 Feb 14, 2008
Jun 12, 2007 38167481L RESOLVE Non-Hazardous 84L10. (84-L-10) REPAIR COMMUNICATION DEVICE (PHONE). $0 $0 Aug 9, 2007
Apr 11, 2007 34418378L RESOLVE Hazardous FAILAURE TO PROVIDE SIDE WALK SHED ON SOUTH ELEVATION OF ITS FACADE BENEATH UNSAFE CONDITION & PROTECT PUBLIC SAFETY;... $2,000 $0 Jun 1, 2007
Jul 27, 2006 38159669N RESOLVE Non-Hazardous 39O02,83X10-(39-O02)CLEAN MOTOR ROOM(83-X-10)RETURN TO SERVICE FOR PROPER INSPECTION $0 $0 Sep 14, 2006
Jun 21, 2006 38159977P RESOLVE Non-Hazardous 83X10/86D06 83-RETURN DEVICE TO SERVICE. 56 SECURE CITY I.D. TAGS TO MAIN MACHINE;PROVIDE NUMERALS FOR ALL MOTOR DEVI... $0 $0 Aug 10, 2006
May 19, 2003 34384484M RESOLVE Non-Hazardous FAILURE TO SUBMIT A FIFTH ROUND TECHNICAL REPORT: PERIODIC INSPECTION OF EXTERIOR WALLS AND APPURTENANCES AS REQUIRED... $350 $0 Dec 4, 2003
Nov 26, 2002 38134118X RESOLVE Non-Hazardous 52M07-54Y11-36D02. 52-M-07 PROVIDE CITY "ID" TAG ON MACHINE 54-Y-11 OIL ON BRAKE SHOES REPAIR 36-0-02 CLEAN TOP OF CAR. $0 $0 Jan 16, 2003
Nov 26, 2002 38134117Y RESOLVE Non-Hazardous 54Y11-36O02. 54-Y-11 OIZ ON BRAKE SHOES REPAIR 36-O-02 CLEAN TOP OF CAR. $180 $0 Jan 16, 2003
Nov 26, 2002 38134116M RESOLVE Non-Hazardous 54L11-54Y11-39D06-36B07-16E01. 54-L-11 REPAIR BRAKE PLUNGER ADJUST BRAKE BRAKE NOT LIFTING PROPERLY (54-Y-11) OIL ON ... $0 $0 Jan 16, 2003
Nov 26, 2002 38134119H RESOLVE Non-Hazardous 59H12-54Y11-16L11-36M07. 59-H-12 CANOT READ CITY "ID" NUMBER ON TAG REPLACE (LEDGABLE) 54-Y-11 OIL AN BRAKE SHOES REP... $0 $0 Jan 16, 2003
Aug 1, 2002 38124474N RESOLVE Non-Hazardous 02L11/ 18D06/ 02 REPAIR DEFECTIVE ALARM SYSTEM ALARM MUST SOUND DURING OPERATION OF DEVICE 18 - BASEMENT DOOR LOCK LO... $440 $0 Sep 19, 2002
Aug 1, 2002 38124473L RESOLVE Non-Hazardous 50H11/ 55L11/ 50- HOIST MOTOR ARMATURE HA SHIGH BARS 55 - REPAIR PIT LIGHT $0 $0 Sep 19, 2002
Jul 26, 2002 38124753X RESOLVE Non-Hazardous 75#05/50Y11/35R09/ 75#05 PERFORMED AND FILE FOR THE TEST TEST EXPIRED ON 11/2000 AS PER DOB RECORDS 50Y11/REPAIR OIL ... $350 $0 Sep 12, 2002
Jun 19, 2002 38124088P RESOLVE Non-Hazardous 2L11/ 50Y14/ 55L12/ 2-L-11 ALARM BELL NOT WORKING 50-Y-14 MACHINE LEAKING 55-L-12 PIT LIGHT $0 $0 Aug 8, 2002
Jun 19, 2002 38124087N RESOLVE Non-Hazardous 50Y14/ 54B11/ 55L12/ 50-Y-14 MACHINE LEAKING 54-B-11 HOIST MOTOR A MATURE HAS HIGH BARS 55-L-12 PIT LIGHT $0 $0 Aug 8, 2002
Jun 19, 2002 38124086L RESOLVE Non-Hazardous 6L11/ 2L11/ 6-L-11 BASEMENT DOOR & INTERLOCK NEED TO NE REPAIRED 2-L-11 ALARM BELL NEEDS TO BE REPAIRED ( SIDEWALK CAR ) $0 $0 Aug 8, 2002
Jun 19, 2002 38124090Y RESOLVE Non-Hazardous 50Y14/ 55L12/ 46B13/ 50-Y-14 MACHINE LEAKING 55-L-12 PIT LIGHT 46-B-13 RESHACKLE HOIST ROPES $0 $0 Aug 8, 2002
Jun 19, 2002 38124089R RESOLVE Non-Hazardous 32Q12/ 50Y14/ 55L12/ 32-Q-12 NO COVER ON HALK WAY BOX 50-Y-14 MACHINE LEAKING 55-L-12 PIT LIGHT $0 $0 Aug 8, 2002
Sep 12, 1998 34183180M RESOLVE Non-Hazardous FAILURE TO CARRY OUT PERMITTED WORK IN ACCORDANCE WITH APPLICABLE LAWSAND REGULATIONS IN THAT CONSTRUCTION ACTIVITIES... $0 $0 Apr 24, 2003
Sep 9, 1998 34181296P RESOLVE Non-Hazardous NO TENANT SAFETY PLANS. NOTED: NO TENANT SAFETY PLAN FOR OCCUPIED S.R.O. UNDER CONSTRUCTION UNDER ALT #101151968 PLAN... $2,500 $0 Oct 29, 1998
Apr 19, 1997 38059106L RESOLVE Hazardous 01 M 02 M 05 L 06 R 10 L 11 R14 M 16 M 18 L 18 Q 19 M 20 L 22 M 26 L 27 L 28 R 30 I 31 L 31 L 34 I 40 L 52 L 60 L 63 ... $500 $0 Jun 5, 1997
Apr 19, 1997 38059107N RESOLVE Non-Hazardous 03 R 18 75 T 39 H 03R- REMOVED AND INSTALLATION OF NEW CAB, CAR STATION, DOOR OPERATOR ETC. STOP WORK UNITS AN APPLIC... $550 $0 Jul 31, 1997
Apr 19, 1997 38059108P RESOLVE Non-Hazardous 03 R 10 R 15 R 75 T 03R- REMOVED AND REPLACEMENT OF CAB, PANELS OPERATOR ETC. STOP WORK WITH AN APPLICATION AND PERMI... $550 $0 Jul 31, 1997
Apr 19, 1997 38059104H RESOLVE Hazardous 01 M 02 M 05 I 06 M 10 L 11 R 15 L 16 M 18 L 22 M 26 L 27 L 28 L 30 I 32 R 34 I 34 I 37 L 40 X 50 Y 60 L 63 H 73 O 75... $500 $0 Jun 5, 1997
Apr 19, 1997 38059109R RESOLVE Non-Hazardous 75 73- MAKE ALL NECESSARY REPAIRS IN ORDER TO RESTORE TO SERVICE, SO THAT A FILL INSPECTION CAN BE MADE BY THIS DEPT. $200 $0 Jun 5, 1997
Sep 25, 1996 38057346L RESOLVE Non-Hazardous 73X,. 73- RESTORE ELEVATOR BACK IN SERVISE FOR COMPLETE INSPECTION. $0 $0 Nov 14, 1996
Aug 23, 1996 34138391J RESOLVE Hazardous FAILURE TO MAINTIAN EXTERIOR BUILDING WALL- DEFECTS ARE: (1) CRACKS IN NORTH EXTERIOR WALL (BRICKS) CAUSE WATER INFIL... $800 $0 Nov 14, 1996
Jul 8, 1996 38055602M RESOLVE Non-Hazardous 73X-BOTH ELEVATORS NOT RUNNING NEED TO BE REPAIRED MAKE REPAIRS AND RETURN TO SERVICE $0 $0 Sep 19, 1996
May 6, 1996 38055570R RESOLVE Non-Hazardous 50Y,37R. 50 SEAL MACHINE OF OIL LEAK 37 REMOVE PAPER FROM RELAYS 11,14,15,16-DISPACHER AND JUMPER BEHIND CONTROL-CLEA... $1,000 $0 Aug 1, 1996
Nov 3, 1995 34132438K RESOLVE Non-Hazardous WORK WITHOUT A PERMIT WORK NOTED SUPPENDED CEILING INSTALLED IN LOBBY ENTRANCE REMEDY FILE PLANS OBTAIN APPROVALS AND... $0 $0 Jan 19, 1996
Oct 30, 1995 38052511N RESOLVE Non-Hazardous 74#,.RESTORE FIREMENS SERVICE TO PROPER OPERATION. $0 $0 Jan 30, 1996
Oct 30, 1995 38052508M RESOLVE Non-Hazardous 74#,. 74 RESTORE FIREMENS SERVICE TO PROPER OPERATION. $0 $0 Jan 30, 1996
Oct 30, 1995 38052509Y RESOLVE Non-Hazardous 74#, 74- RESTORE FIREMENS SERVICE TO PROPER OPERATION. $0 $0 Jan 30, 1996
Oct 30, 1995 38052510L RESOLVE Non-Hazardous 74#, 74 RESTORE FIREMEN'S SERVICE TO PROPER OPERATION. $0 $0 Jan 30, 1996
Sep 20, 1995 34130840J RESOLVE Non-Hazardous FAILURE TO MAINTAIN DEFECT NOTED NO LIGHTING IN NORTH STAIRWELL, TREADS BROKEN, MISSING AND DEFECTIVE 23RD STORY NORT... $0 $0 Jan 7, 2000
Jun 6, 1994 38042740H RESOLVE Non-Hazardous 74I,74AI,20L,74A,18L,57Z,1I,1I,74BL,74CL.(74) REPAIR OR RENEW THE CAR FLOOR (74A) REPAIR ANNUNCIATION (180 BASEMENT (... $0 $0 Aug 18, 1994
Jun 6, 1994 38042741J RESOLVE Non-Hazardous 73X,15I,46H,20L,74L,5I,6I,6I,1L. (150 FIRST FLOOR (79) REPAIR ANNONCIATER $0 $0 Aug 18, 1994
Jun 6, 1994 38043806X RESOLVE Non-Hazardous 52H,11B,74L,74M,21L,20L,74L,15L,15L. 74/REPAIR CAR FAN. 74A/PROVIDE FAN GUARD. 74B/REPAIR THE FIREMAN'S SERVICE AND D... $5,000 $0 Oct 13, 1994
Jun 6, 1994 38043807H RESOLVE Non-Hazardous 74L,74M,11B,20L,73X,74#,10I,10I,15I,74L. 74/REPAIR CAR FAN. 74/PROVIDEFAN GUARD. 74/REPAIR THE ELEVATOR SO IT RUNS AT... $5,000 $0 Oct 13, 1994
Jun 6, 1994 38042738Z RESOLVE Non-Hazardous 52H,11B,74L,74(A)M,21L,20L,74(B)L,15L,5L, (74) REPAIR CAR FAN 74(A) PROVIDE FAN GUARD 74(B) REPAIR THE FIREMAN'S SERV... $0 $0 Aug 18, 1994
Jun 6, 1994 38042739K RESOLVE Non-Hazardous CE ,7A(A)M,11B,20L,73X,74(B)#,10I,10I,15I,74(C)L, (74) REPAIR CAR FAN (74A) PROVIDE FAN GUARD (74B) REPAIR THE ELEVAT... $0 $0 Aug 18, 1994
Jan 3, 1994 38039804K RESOLVE Hazardous 52H,28H,74L, (74) PHASE II FIRE SERVICE NOT OPERATING CAR (ELEV) GOES BACK & FORTH FROM ONE FLOOR TO ANOTHER WITHOUT ... $1,250 $0 Feb 3, 1994
Dec 30, 1993 38039803Z RESOLVE Non-Hazardous 75#, (75) PERFORM A FULL LOAD TEST IN PRESENCE OF INSPECTOR FROM THIS DEPT. $0 $0 May 5, 1994
Dec 29, 1993 34104551Y RESOLVE Non-Hazardous FAILURE TO MAINTAIN INTERIOR. NOTED: THE LOBBY SUSPENDED CEILING IS BROKEN MISSING AND DEFECTIVE - INSTALLED CONTRARY... $175 $0 May 5, 1994
Dec 29, 1993 34104552X RESOLVE Non-Hazardous WORK WITHOUT A PERMIT STOP WORK ORDER NOTED: REPAIR TO EXISTING SUSPENDED CEILING IN HEALTH DISAPPROVED 12/21/93. STO... $0 $0 Feb 10, 1994
Nov 22, 1993 38038695X RESOLVE Non-Hazardous 74# MAEK NECESSARY REPAIRS FOR THE SUCCESSFUL PERFORMANCE OF A FULL LOAD TEST AND FIREMANS RECALL TEST PHASES I & II $200 $0 Feb 3, 1994
Nov 3, 1993 38038682R RESOLVE Non-Hazardous 75#,74#. 75 PERFORM A FULL LOAD TEST AND 74 A FIREMANS SERVICE TEST INTHE PRESENCE OF AN INSPECTOR FORM THIS DEPT. MA... $200 $0 Feb 24, 1994