ECB violations
131 East 31 Street, Manhattan • Block 00887 • Lot 0023
28 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Sep 5, 2023 | 39521394Z | RESOLVE | CLASS - 2 | AT THE TIME OF INSPECTION, I OBSERVED THAT SITE SAFETY DOCUMENTATION ON SITE WAS INADEQUATE: USE OF PRE-FILLED DAILY ... | $0 | $0 | Nov 16, 2023 |
| Sep 5, 2023 | 39521390L | RESOLVE | CLASS - 2 | AT THE TIME OF INSPECTION, I OBSERVED THAT THERE WAS NO NOTIFICATION NUMBER FROM THE DEPARTMENT FOR OUTRIGGER AND COU... | $0 | $0 | May 13, 2024 |
| Sep 5, 2023 | 39521393R | RESOLVE | CLASS - 2 | AT THE TIME OF INSPECTION, I OBSERVED THAT THE SUSPENDED SCAFFOLD PLATFORM IN USE WAS MISSING A LOWERED STRUCTURAL GU... | $0 | $0 | Nov 16, 2023 |
| Sep 5, 2023 | 39521391N | RESOLVE | CLASS - 2 | AT THE TIME OF INSPECTION, I OBSERVED THAT THE CD5 PERMIT FOR OUTRIGGER AND COUNTERWEIGHT ON SITE HAD EXPIRED: STOP T... | $3,125 | $0 | Jun 27, 2024 |
| Sep 5, 2023 | 39521374L | RESOLVE | CLASS - 2 | AT THE TIME OF INSPECTION, I OBSERVED THAT FIST GRIPS SHOWN ON APPROVED PLANS TO HOLD TIE-BACKS AND LIFELINES AT THE ... | $0 | $0 | Nov 16, 2023 |
| Apr 14, 2023 | 39515383M | RESOLVE | CLASS - 2 | OBSERVED EXP1 CONDUIT PIPE CONNECTED TO ELECTRICAL BOX NEAR SIDEWALK PAVER RUNNING INTO CONNECTION WITH VANDAL LIGHT ... | $625 | $0 | Nov 9, 2023 |
| Apr 14, 2023 | 39515382K | RESOLVE | CLASS - 2 | OBSERVED AT ROOF CHOOK CONNECTIONS SCAFFOLD EXP3 COMPLETELY INSTALLED.LICENSE RIGGER ON SITE I.AHMAD FAILED PROVIDE R... | $0 | $0 | Jun 22, 2023 |
| Mar 15, 2023 | 39514179K | RESOLVE | CLASS - 2 | AT THE TIME OF INSPECTION, OBSERVED ERECTED SIDEWALK SHED AT EXPOSURE 1 FOR FACADE ALTERATION WORK OF 17 STORY BUILDI... | $625 | $0 | Nov 16, 2023 |
| Apr 27, 2022 | 35651376P | RESOLVE | CLASS - 1 | FAILURE TO TAKE REQUIRED SAFETY MEASURES TO PROTECT PUBLIC SAFETY FROMDOCUMENTED UNSAFE FACADE NOTE:QEWI SUBMITTED UN... | $10,000 | $0 | Jun 22, 2023 |
| Apr 27, 2022 | 35651375N | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BLDG WALLS OR APPURTENANCES.NOTE:ATOI,OBSERVED SEVERELY CRACKED SPANDREL BEAMS&BALCONY SLABS@4F,9... | $2,500 | $0 | Jun 22, 2023 |
| Jun 1, 2021 | 37021408R | RESOLVE | CLASS - 2 | FAILURE TO SUBMIT ACCEPTABLE REQUIRED CYCLE8B REPORT OF CRITICAL EXAM DOCUMENTING CONDITION OF EXTERIOR WALL&APPURTEN... | $5,000 | $0 | Oct 7, 2021 |
| Oct 15, 2018 | 37012846M | RESOLVE | CLASS - 2 | FAILURE TO SUBMIT A REQUIRED CYCLE 8B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPUR... | $1,250 | $0 | May 9, 2019 |
| Apr 8, 2014 | 35024419N | RESOLVE | CLASS - 2 | REMOVAL OF SHED OR PROTECTIVE MEASURES WITHOUT DEPT APPROVAL SHED HAS BEEN REMOVED WITHOUT DOB APPROVAL REMEDY:COMPLY... | $0 | $0 | Sep 4, 2014 |
| Dec 14, 2012 | 35003380M | RESOLVE | CLASS - 2 | SEC. BC 3301.2 FAILURE TO SAFEGUARD ALL PERSONS AND PROPERTY AFFECTED BY CONSTRUCTION OPERATION. NOTE: AT TIME OF INS... | $0 | $0 | Jan 31, 2013 |
| Sep 17, 2012 | 34952524K | RESOLVE | CLASS - 1 | SEC. 3307.5.2 A FLAG PERSON SHALL BE PROVIDED WHEN EVER INTERMITTENT OPERATIONS ARE CONDUCTED (ON),OR ADJACENT TO,ARE... | $1,630 | $0 | Dec 20, 2012 |
| Nov 22, 2011 | 34897910J | RESOLVE | CLASS - 1 | USE OF SUPPORTED SCAFFOLD W/O A SCAFFOLD USER CERTIFICATE.NOTED:FOUR WORKERS ON SUPPORTED SCAFFOLDS THROUGHOUT THE LO... | $0 | $0 | Jan 12, 2012 |
| Nov 22, 2011 | 34897909M | RESOLVE | CLASS - 2 | FAILURE TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY CONST. OPERATIONS.NOTE:INADEQUATE PROTECTION TO PUBLIC DURING... | $1,200 | $0 | Jan 12, 2012 |
| Nov 22, 2011 | 34897911L | RESOLVE | CLASS - 2 | 3314.1MISC.VIO.SUPPORTED SCAFFOLD DOES NOT MEET CODE SPECIFICATIONS.NOTE:SUPPORTED SCAFF9OLD ERECTED IN LOBBY.MISSING... | $0 | $0 | Jan 12, 2012 |
| Jun 17, 2010 | 34861753K | RESOLVE | CLASS - 2 | FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY - STAIRS FROM CELLAR TO LOBBY LOBBY STAIRWELLS. CHAIR, BASEBALL BAT, ... | $800 | $0 | Aug 12, 2010 |
| Nov 28, 2008 | 36006384J | RESOLVE | CLASS - 2 | FAILURE TO SUBMIT AN ACCEPTABLE 6TH ROUND TECHNICAL REPORT IN COMPLIANCE WITH CODE PROVISIONS: PERIODIC INSPECTION OF... | $800 | $0 | Nov 6, 2009 |
| Aug 11, 2008 | 34689264H | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN DEFECT NOTED ON 17TH FL STAIRWELL # LANDING WINDOW CRACKED BROKEN REMEDY: REPAIR OR REPLACE DEFEC... | $250 | $0 | Oct 2, 2008 |
| Aug 15, 2007 | 34587395K | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN. DEFECTS NOTED: @ FRONT SET BACK OF 2ND FLR. A/C UNITS INSTALLED ON ROOF W/O DUNNAGE OR SUPPORTIN... | $800 | $0 | Oct 11, 2007 |
| Aug 15, 2007 | 34587396M | RESOLVE | Non-Hazardous | EXIT PASSAGEWAY OR CORRIDOR: TOTAL OBSTRUCTION. NOTED @ CELLAR LEVEL NYSC SIDE EXIT CORRIDOR BLOCKED BY CARTS W/ TOWE... | $480 | $0 | Oct 11, 2007 |
| Aug 15, 2007 | 34587394Z | RESOLVE | Non-Hazardous | WORK W/O PERMIT. WORK NOTED: ERECTED WOOD FRAME DECK APPROX 40'X20' & A/C UNITS @ REAR OF PREMISES 2NF FLR ROOF SET B... | $800 | $0 | Oct 11, 2007 |
| Aug 22, 1991 | 34061605N | ACTIVE | Non-Hazardous | OCCUPANCY CONTRARY TO THAT ALLOWED BY THE CERTIFICATE OF OCCUPANCY C OF O.#85900.CELLAR BEING USED AS COMMERICAL SPAC... | $1,000 | $0 | Nov 7, 1991 |
| Nov 9, 1988 | 34014003Y | ACTIVE | Hazardous | WORK WITHOUT A PERMIT NOV ARIANCE WORNK NOTED FRAMING WALLS AT 1 STY REMEDY STOP ALL WORK BEFORE 7AM AND AFTER 6 PM M... | $300 | $0 | Dec 30, 1988 |
| Nov 2, 1988 | 34007561N | RESOLVE | Unknown | WORK WITHOUT A PERMIT EXPIRED PERMIT WORKNOTED REMOVAL OF INTERIOR PARTITION 1 FL HEALTH CLUB PERMIT 10969 FOR APPROV... | $250 | $0 | Jan 19, 1989 |
| Sep 29, 1988 | 34013553Y | RESOLVE | Non-Hazardous | ALTERED BUIDLIG OCCUPIED WITHOUT A VALID C OF O. REMEDY: DISCONTINUE THE ILLEGAL OCCUPANCY UNTIL AN AMENDED C OF O HA... | $250 | $0 | Nov 17, 1988 |