142-146 East 33 Street, Manhattan
Manhattan • Block 00888 • Lot 0055 • Zip: 10016
Condition
What the city currently has open against this building, counted from its own records.
Address
Land use and zoning
Building
Latest assessment
Neighborhood
The area this lot falls inside, and the commute Hoodkit measures from it.
Getting around
Estimated 2 days ago- Grand Central 15 min 9 walking, 6 riding
- Union Square 15 min 9 walking, 6 riding
- Times Square 22 min 9 walking, 13 riding
- Fulton Street 25 min 9 walking, 16 riding
- Penn Station 29 min 9 walking, 20 riding
- Downtown Brooklyn 32 min 9 walking, 23 riding
Around this address
Transit and places within 0.5 miles of the lot.
Getting out
Subway
Railroad
Ferry
Bus
Citi Bike
Places nearby
Eleven Madison Park
No description yet
Ai Fiori
No description yet
John Dory Oyster Bar
No description yet
Ambassadors Clubhouse
No description yet
Milk Bar
No description yet
The NoMad Restaurant
No description yet
2nd Ave Deli
2nd Ave Deli is a classic Jewish deli in NYC serving up traditional dishes like matzo ball soup and pastrami sandwich...
Atomix
Atomix is a modern Korean fine dining experience in the heart of NYC. With an intimate atmosphere and sleek decor, gu...
Activity
Sales, filings, permits and violations from every dataset, in one order.
2023
-
HPD violation Mar 15, 2023
Class A
(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION ...
2022
-
DOB violation Aug 3, 2022
BENCH-FAILURE TO BENCHMARK NONE
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
-
DOB violation Jun 2, 2022
BENCH-FAILURE TO BENCHMARK NONE
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
2019
-
DOB violation Feb 26, 2019
E-ELEVATOR ELEVATORREQUIRED
2018
-
DOB violation Jan 26, 2018
ACC1-(OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION ELEVATORREQUIRED
VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2016 CAT 1 INSP/TST
2017
-
DOB violation Jan 3, 2017
ACC1-(OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION ELEVATORREQUIRED
VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2015 CAT 1 INSP/TST
2016
-
DOB violation Feb 22, 2016
E-ELEVATOR ELEVATORREQUIRED
2012
-
Alteration Type II
REPLACE OIL BURNER ON EXISTING BOILER NO. MD21777-01 AND CHANGE GRADE OF FUEL OIL FROM #4 TO #2. THIS APPLICATION IS ...
2009
-
Alteration Type III
PARAPET REPAIR AND BRICK REPLACEMENT PROJECT AS PER PLANS. NO CHANGE IN USE OCCUPANCY OR EGRESS UNDER THIS APPLICATIO...
2008
-
Alteration Type III
PROPOSED INSTALLATION OF HEAVYDDUTY SIDEWALK SHED FOR REMEDIAL REPAIRS AS PER PLANS. NO CHANGE IN USE OCCUPANCY OR EG...
-
CLASS - 1
FAILURE TO INSTITUTE/MAINTAIN SAFETY EQUIPMENT MEASURES OR TEMPORARY CONST. - NO TOE BOARDS. NOTED: NO TOE BOARD ON S...
-
CLASS - 2
WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND/OR APPROVED AMENDMENTS. NOTED: TIEBACKS SET UP DIFFERENT...
-
CLASS - 2
LICENSED RIGGER FAILED TO ENSURE SCAFFOLD WORKER MET MINIMUM REQ. NOTED: WORKER ON SUSPENDED SCAFFOLD W/O CERTIFICATE...
-
CLASS - 1
FAILURE TO PERFORM SAFE/PROPER INSPECTION OF SUSPENDED SCAFFOLD. NOTED: NO MAINTENANCE LOG BOOK ON SITE. REMEDY: CONF...
-
CLASS - 1
LIFELINES SHALL BE PROTECTED FROM SHARP EDGES AND ABRASIONS. NOTED: NOPROTECTION FOR LIFELINE FROM SHARP EDGES. REMED...
-
CLASS - 1
FAILURE TO PROVIDE/USE LIFELINE WHILE WORKING ON SCAFFOLD. NOTED: WORKERS ON SUSPENDED SCAFFOLD W/O HARNESS ON. REMED...
The most recent 6 events from each dataset, so no one source takes the axis. Each tab holds the full record.
Property Contacts
Contact information aggregated from multiple government sources
Registration Contracts
Contact information from multiple dwelling registrations
Building Permits
Owner information from Department of Buildings filings
Deed Records
Parties from ACRIS deed and mortgage records
Property Records
Owner information from assessment and PLUTO records