219 East 26 Street, Manhattan
Manhattan • Block 00907 • Lot 0013 • Zip: 10010
Condition
What the city currently has open against this building, counted from its own records.
Address
Land use and zoning
Building
Latest assessment
Neighborhood
The area this lot falls inside, and the commute Hoodkit measures from it.
Getting around
Estimated 4 days ago- Grand Central 15 min 9 walking, 6 riding
- Union Square 15 min 9 walking, 6 riding
- Times Square 22 min 9 walking, 13 riding
- Fulton Street 25 min 9 walking, 16 riding
- Penn Station 29 min 9 walking, 20 riding
- Downtown Brooklyn 32 min 9 walking, 23 riding
Around this address
Transit and places within 0.5 miles of the lot.
Getting out
Subway
Railroad
Ferry
Bus
Citi Bike
Places nearby
Cafe Carmellini
No description yet
Eleven Madison Park
No description yet
Clemente Bar
No description yet
La Tete d’Or
No description yet
Old Town Bar
No description yet
Borgo
Experience the charm of Italy in the heart of NYC at Borgo. This cozy, rustic spot offers authentic Italian cuisine, ...
abcV
No description yet
ABC Kitchen
No description yet
Activity
Sales, filings, permits and violations from every dataset, in one order.
2026
2020
-
CLASS - 2
WORK WITHOUT PERMIT.OBSERVED AT EXPOSURE# 1 EXTERIOR CIRCULAR EXHAUST FAN APPROX.18 INCHES IN DIAMETER AND 10FT ABOVE...
2017
-
HPD violation Oct 18, 2017
Class B
§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CONCRETE LINTEL AT 1ST WINDOW FROM W...
-
HPD violation Oct 18, 2017
Class B
§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CONCRETE LINTEL AT 1ST WINDOW FROM W...
-
HPD violation Oct 18, 2017
Class B
§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CONCRETE LINTEL AT 4TH WINDOW FROM W...
-
Alteration Type II
REPLACE BOILER AND OIL BURNER. (NYC BOILER NO. MD20784-01 WITH BOILER AND GAS/OIL BURNER AND INSTALL NEW GAS SERVICE,...
2016
-
HPD violation May 18, 2016
Class B
§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED A...
-
HPD violation May 18, 2016
Class C
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE KITC...
-
HPD violation May 18, 2016
Class B
§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR BROKEN IN THE ENTIRE APARTMENT LOCATED AT APT 6, 2nd STORY, 1...
2015
2014
-
DOB violation May 15, 2014
LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2012 INSPECTION REPORT
2008
2003
-
Non-Hazardous
44A/48A/32A/50 44A>STEAM GAGE DOES NOT READ UP TO 30 PSI AS REQUIRED 32>MISSING COVERS ON PRESSURE CONTROLS ANDOIL 50...
1993
-
DOB violation Mar 18, 1993
LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED
The most recent 6 events from each dataset, so no one source takes the axis. Each tab holds the full record.
Property Contacts
Contact information aggregated from multiple government sources
Registration Contracts
Contact information from multiple dwelling registrations
Building Permits
Owner information from Department of Buildings filings
Recent Building Permits
Owner information from recent DOB NOW filings
Deed Records
Parties from ACRIS deed and mortgage records
Property Records
Owner information from assessment and PLUTO records