ECB violations
American Copper Building, Manhattan • Block 00967 • Lot 0001
78 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Dec 11, 2014 | 35121614N | RESOLVE | CLASS - 1 | SEC. 3307.7 FENCE GATES W/SOLID SLIDING OR IN SWINGING GATES ARE REQUIRED. NOTED: GATES AT EXPOSURE 1 & 3 SWING OUT -... | $1,600 | $0 | Jan 29, 2015 |
| Sep 30, 2014 | 35034921H | RESOLVE | CLASS - 2 | CD4568 CN 36/14 SWO093014DKM01. FAILURE TO COMPLY W/CERT OF ONSITE WRONG USER WAS IN CRANE. I WITNESSED SSC HIGH RISE... | $2,400 | $0 | Nov 20, 2014 |
| Sep 30, 2014 | 35034922J | RESOLVE | CLASS - 1 | INADEQUATE SAFETY MEASURES USE OF HOISTING EQUIPMENT IN UNSAFE MANNER.I WITNESSED DEMO CREW REMOVING HORIZONTAL BRAZI... | $4,800 | $0 | Nov 20, 2014 |
| Sep 18, 2014 | 34982295N | RESOLVE | CLASS - 1 | SEC. 3309.6;1814.3 FAILURE TO MONITOR ADJOINING STRUCTURES FOR MOVEMENT IN ALL DIRECTIONS DURING EXCAVATION RELATED A... | $1,600 | $0 | Jan 29, 2015 |
| Sep 11, 2014 | 35034938Y | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD ALL PERSONS AFFECTED BY CONSTRUCTION OPERATIONS. MR. MATTHEW KEANE WAS LIFTING A PERSON ON THE H... | $2,400 | $0 | Oct 30, 2014 |
| Apr 14, 2014 | 35067169J | RESOLVE | CLASS - 2 | WORK DOES NOT CONFORM TO APPROVED CONST DOCS &/OR APPROVED AMENDMENTS.AT THE TIME OF INSP THE INSTALLATION OF THE SUP... | $250 | $0 | May 29, 2014 |
| Apr 14, 2014 | 35067170R | RESOLVE | CLASS - 2 | 3304.2 FAILURE TO ADEQUATELY SUPPORT ADJOINING GROUND & STRUCTURES AFFECTED BY EXCAVATION.@ THE TIME OF INSP THERE WE... | $0 | $0 | May 29, 2014 |
| Feb 15, 2014 | 35085401Y | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. NOTE: AT CELLARLEVEL IN GARAGE FIRE EXIT DOORS LEADING TO FIRE... | $0 | $0 | Apr 3, 2014 |
| Jan 16, 2014 | 35007603Z | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS DURING THE INSTALLATION OF CAISSON PI... | $2,400 | $0 | Mar 6, 2014 |
| Nov 20, 2013 | 35080621N | RESOLVE | CLASS - 2 | PROJEDT INFORMATION PANEL/CONSTRUCTION SIGN NOT PROVIDED OR NOT IN COMPLIANCE W/SECTION.NOTED CONSTRUCTION FENCE EREC... | $0 | $0 | Jan 9, 2014 |
| Oct 15, 2013 | 35032444P | RESOLVE | CLASS - 2 | SEC. BC 3301.5. AT TIME OF INSPECTION. NO MAINTENANCE LOG WAS PRESENT FOR DRILLING EQUIPMENT AT SITE UPON REQUEST. AS... | $0 | $0 | Dec 5, 2013 |
| Oct 15, 2013 | 35032443N | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD ALL PERSONS AND PROPERTY AFFECTED BY CONSTRUCTIONOPERATIONS. AS PER FOREMAN DURING EXCAVATION DR... | $2,400 | $0 | Dec 5, 2013 |
| Oct 15, 2013 | 35032446Z | RESOLVE | CLASS - 2 | SEC. BC 3310.3 FAILURE TO HAVE SITE SAFETY PLANS AND PROGRAM AS REQUIRED. AT TIME OF INSPECTION NO PW-2 ON FILE FOR S... | $0 | $0 | Dec 5, 2013 |
| Jun 21, 2013 | 38226620J | RESOLVE | CLASS - 1 | BC3318.4 97##,97##,61B11. 97##-AS PER 810.4 81 RULE NUMBER 19.13 AND RULE 21.4 THE CAGE WEIGHT (6800) PLUS COR CAPACI... | $1,600 | $0 | Oct 3, 2013 |
| Jun 21, 2013 | 38226621L | RESOLVE | CLASS - 1 | BC3318.4 97##,97## 97##-PROVIDE PROPER CAT HEAD.REFER TO FIGURE 3-16OF MANUFACTURER MANUAL; 97## CHANGE DAMAGED COUNT... | $1,600 | $0 | Oct 9, 2013 |
| Oct 5, 2012 | 34995659H | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS - AT TIME OF INCIDENT AS REPORTED BY ... | $2,400 | $0 | Jan 10, 2013 |
| Jun 16, 2012 | 34981964R | RESOLVE | CLASS - 1 | 3308.3:VERTICAL SAFETY NETTING NOT PER CODE DAMAGED OR IN ADEQUATE. NOTED:AT TIME OF INSPECTION AT ACTIVE JOB SITE OB... | $1,600 | $0 | Aug 2, 2012 |
| Jun 16, 2012 | 34981963P | RESOLVE | CLASS - 2 | WORK CONTRARY TO VARIANCE WORK OTHER THAN STATED ON VARIANCE. NOTED:ATTIME OF INSPECTION AT ACTIVE JOB SITE OBSERVED ... | $800 | $0 | Aug 2, 2012 |
| Mar 15, 2012 | 34940932L | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN HOUSEKEEPING AT TIME OF INSPECTION OBSERVED A HUGEPILE OF DEBRIS ON THE 5TH FL DECK-THE 5TH FLOOR... | $2,400 | $0 | Jun 21, 2012 |
| Mar 15, 2012 | 34940931J | RESOLVE | CLASS - 1 | SEC. 3308.1.1 FAILURE TO PROVIDE VERTICAL NETS-PARTIAL STOP WORK ORDERISSUED PURSUANT TO 28-207.2 & POSTED AT PREMISE... | $1,600 | $0 | Jun 21, 2012 |
| Jan 9, 2012 | 34933172M | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS-STEEL WORKER NOT TIED-OFF,FELL APPROX... | $2,400 | $0 | Feb 23, 2012 |
| Mar 16, 2010 | 34820216Y | RESOLVE | CLASS - 2 | SEC. 27-1031D. EXCAVATION NOT ADEQUATELY DRAINED OF RAIN WATER AND/OR SUB-SURFACE WATER. AT TIME OF INSPECTION I DID ... | $0 | $0 | May 6, 2010 |
| Dec 9, 2008 | 34742747M | RESOLVE | CLASS - 1 | SEC H114.2.3 OUTDOOR ADVERTISING COMPANY FAILURE TO AFFIX DATE OF SIGNS ERECTION TO OUTDOOR ADVERTISING SIGN REM: REM... | $0 | $0 | Dec 30, 2010 |
| Dec 7, 2008 | 36006433R | RESOLVE | CLASS - 2 | FAILURE TO SUBMIT AN ACCEPTABLE 6TH RD TECHNICAL REPORT IN COMPLIANCE W/CODE PROVISIONS: PERIODIC INSPECTION OF EXTER... | $0 | $0 | Jun 11, 2009 |
| Nov 13, 2006 | 34556880M | RESOLVE | Hazardous | FAILURE TO MAINTAIN EXTERIOR OBSERVED - ON THE SOUTH FENCE OF THE PROPERTY A METAL SIGN APPROX 3 FT X 7 FT DETACHED &... | $800 | $0 | Mar 8, 2007 |
| Oct 15, 1991 | 34063404X | RESOLVE | Unknown | WORK WITHOUT PERMIT-IN THAT A SIDEWALK SHED HAS BEEN ERECTED. DEPT. RECORDS SHOW PERMIT HAS EXPIRED. REMEDY: RENEW PE... | $1,000 | $0 | Dec 26, 1991 |
| Aug 22, 1990 | 34044019X | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN EXTERIOR WALL. SECTION OF MASONARY CORNICE IS BROKEN CRACKED AND MISSING OVER 10 STORY AT NORTHEA... | $285 | $0 | Nov 8, 1990 |
| Nov 3, 1988 | 34016048R | RESOLVE | Non-Hazardous | THE CRACKED SECTION EXTERIOR BUILDING WALL DEFECT IS AT THE NORTH EAST SECTION OF THE PARAPET WALL HAS BEEN PREVIOUS ... | $125 | $0 | Jan 6, 1989 |