157-163 West 47 Street, Manhattan
Manhattan • Block 01000 • Lot 0007 • Zip: 10036
Condition
What the city currently has open against this building, counted from its own records.
Address
Land use and zoning
Building
Latest assessment
Neighborhood
The area this lot falls inside, and the commute Hoodkit measures from it.
Getting around
Estimated 4 days ago- Times Square 8 min 2 walking, 6 riding
- Union Square 13 min 2 walking, 11 riding
- Grand Central 15 min 2 walking, 13 riding
- Penn Station 16 min 2 walking, 14 riding
- Fulton Street 26 min 2 walking, 24 riding
- Downtown Brooklyn 29 min 2 walking, 27 riding
Around this address
Transit and places within 0.5 miles of the lot.
Getting out
Subway
Railroad
Ferry
Bus
Citi Bike
Places nearby
Gallaghers Steakhouse
Iconic steakhouse offering classic cuts & raw bar items in renovated digs with red banquettes.
Le Bernardin
No description yet
Chalong
No description yet
Los Tacos No. 1
Experience the authentic flavors of Mexico at Los Tacos No. 1! Located in the heart of NYC, enjoy hand-pressed tortil...
Cuerno
No description yet
Din Tai Fung
Chinese restaurant
Danji
Upscale creative Korean small plates, cocktails & an emphasis on organic/sustainable ingredients.
Double Knot
No description yet
Activity
Sales, filings, permits and violations from every dataset, in one order.
2026
-
HPD violation Apr 29, 2026
Class A
(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION ...
2025
-
Alteration Type II
INSTALLATION OF TEMPORARY SHORING AND NEW EXTERIOR WALL FOR SIDE EXTENSION AS PER PLANS FILED HEREWITH.
2024
-
HPD violation Nov 22, 2024
Class I
§27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27...
-
CLASS - 2
FAILURE TO MAINTAIN BUILDINGS EXTERIOR WALLS AND/OR APPURTENANCES.-AT TIME OF INSPECTION, OBSERVED LOW PERCENT WALL, ...
-
HPD violation Jul 8, 2024
Class A
§ 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR...
-
HPD violation Jul 8, 2024
Class A
§ 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COM...
-
HPD violation Jul 8, 2024
Class A
§ 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED...
-
HPD violation Jul 8, 2024
Class A
§ 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE ...
-
Alteration Type III
1- Remove old existing concrete slab & replace with new steel beams & concrete steel deck at 1st floor. ( OT/...
-
Alteration Type II
REPLACE BATHROOM FIXTURES IN ROOMS 1002 THRU 1009 AS PER PLAN.ADD ONE BATHROOM FIXTURES NEW AS SHOW ON PLAN CONSTRUCT...
-
Alteration Type II
SECONG THROUGH NINTH FLOORS REMOVEINTERIOR PARTITIONS & PLUMBING FIXTURES . NO CHANGE IN USE,EGRESS OROCCUPANCY
-
DOB violation Jan 8, 2024
FISPHAZ-HAZARDOUS CONDITION (FACADE) FACADE REQUIRED
CYCLE 9B UNSAFE REPORT FILED
2023
-
Alteration Type III
1- Remove South shaft wall of North shaft at cellar and 1st floor levels. 2- Obtain OT/GC permits. 3- All of above as...
-
DOB violation Nov 3, 2023
BENCH-FAILURE TO BENCHMARK NONE
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
-
DOB violation Nov 1, 2023
FISPFCS-FAILURE TO CORRECT SWARMP CONDITIONS (FACADE) FACADE REQUIRED
FAILURE TO CORRECT SWARMP CONDITIONS
-
Alteration Type III
INSTALLATION OF A HEAVY DUTY SHED 120' DURING FACADE REPAIR. NO CHANGE IN USE, EGRESS OR OCCUPANCY. SHED TO COMPLY WI...
-
DOB violation Aug 3, 2023
BENCH-FAILURE TO BENCHMARK NONE
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
-
DOB violation May 3, 2023
BENCH-FAILURE TO BENCHMARK NONE
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
2021
-
CLASS - 2
FAILURE TO MAINTAIN BUILDING EXTERIOR WALLS/FACADES AND APPURTENANCES.EXPOSURE 1,SOUTH ELEVATION:PARAPET WALL-SPALLED...
2020
-
DOB violation Sep 21, 2020
E-ELEVATOR ELEVATORREQUIRED
2019
2018
-
CLASS - 1
CU52BB12; 68B7; 59BB15. CEASE USE ITEM; BASEMENT DRUM MACHINE LAST RESHACKLED OCTOBER 2013. ANNUAL BRAKE MAINTENANCE ...
-
CLASS - 2
FAILURE TO SUBMIT A REQUIRED CYCLE 8B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPUR...
2017
-
CLASS - 1
5A10;56Y13;56Y2;39O2/5-A-10-DOOR ZONE RESTRICTOR ALTERED REPAIR.THIS IS A SAFETY DEVICE RENDERED INOPERATIVE.
2016
2015
2014
2013
2012
-
CLASS - 1
ELECTRICAL WORK W/O A PERMIT OUTDOOR PROJECTORS IN FRONT OF THE HOTEL. REM: OBTAIN PERMIT.
2008
The most recent 6 events from each dataset, so no one source takes the axis. Each tab holds the full record.
Property Contacts
Contact information aggregated from multiple government sources
Registration Contracts
Contact information from multiple dwelling registrations
Building Permits
Owner information from Department of Buildings filings
Recent Building Permits
Owner information from recent DOB NOW filings
Deed Records
Parties from ACRIS deed and mortgage records
Property Records
Owner information from assessment and PLUTO records