ECB violations

159-161 West 54 Street, Manhattan • Block 01007 • Lot 0001

47 records

Environmental Control Board violations, which carry a hearing and a penalty.

Issued Violation Status Severity Description Penalty Balance due Hearing
Jun 2, 2026 39190780N ACTIVE CLASS - 1 CLASS 1 PHASE I INOPERATIVE REPAIR.. $1,250 $0 Aug 6, 2026
Jan 6, 2026 39172652J RESOLVE CLASS - 1 5/X/10 CAR CEASE USE, CLASS 1, CAR DOOR RESTRICTOR IS NOT WORKING DEFECTIVE REPAIR. $1,250 $0 Mar 12, 2026
Jun 3, 2025 39149699L RESOLVE CLASS - 1 CLASS 1(CU):DOOR ZONE RESTRICTOR INOPERATIVE,REPAIR AND TEST DEVICE (CU).CLASS 2:NO MAINTENANCE LOG PRESENT,PREFORM M... $1,250 $0 Aug 7, 2025
May 13, 2025 39147875M RESOLVE CLASS - 1 AT TIME OF INSPECTION OBSERVED LARGE AMOUNTS OF DEBRIS SCATTERED THROUGHOUT AT APT:#1301,13TH FL, CREATING A HAZARD F... $2,500 $2,500 Jul 17, 2025
Feb 4, 2025 39137395Y RESOLVE CLASS - 1 UPON INSPECTION OBSERVED AT 8FLR./APT.803, SEVERAL LIGHT FIXTURES HAVE BEEN DISCONNECTED FROM THE CEILING TO INSTALL ... $1,250 $0 Apr 10, 2025
Nov 20, 2024 39130885P RESOLVE CLASS - 1 9THFL LOCATION EXPOSURES 1&4 APPROX 90' IN HEIGHT OBSERVE THE WERE NO SIDEWALK SHED IN PLACE AS REQUIRED ON APT:#902 ... $10,000 $10,000 Aug 17, 2026
Nov 20, 2024 39130900Y RESOLVE CLASS - 1 FTC WITH TPP. ATOI OBSERVED FIRESTOPPING NOT REPLACED IN APARTMENTS 304 AND 904 CONTRARY TO TPP FOR JOB#M01113040-I1-... $2,500 $2,500 Jul 21, 2025
Nov 20, 2024 39130899X RESOLVE CLASS - 1 AT TIME OF INSPECTION I OBSERVED MISSING FIRESTOPPING ON WALL IN APARTMENTS 304 AND 904., PROVIDE/MAINTAIN FIRE STOPPING $625 $625 Jul 21, 2025
Jul 29, 2024 39120133N RESOLVE CLASS - 2 OBSERVED ON THE 10TH FLOOR IN APARTMENT 1002 INSTALLED IN THE KITCHEN UNDER THE KITCHEN SINK PVC PIPING ON WASTE LINE... $1,250 $0 Dec 5, 2024
Jul 29, 2024 39120134P RESOLVE CLASS - 2 OBSERVED ON THE 10TH FLOOR IN APARTMENT 1002 IN THE KITCHEN AN OPEN ENDED GAS LINE, FUTURE ON GAS LINE, PVC PIPING IN... $625 $0 Dec 5, 2024
Jul 24, 2024 39119798J RESOLVE CLASS - 2 OBSERVED AT THE ROOF LEVEL CONTROL VALVE FOR GRAVITY TANK FOR STAND PIPE NOT CHAINED AND LOCKED., REPAIR AND/OR REPLACE $0 $0 Oct 3, 2024
Jul 24, 2024 39119799L RESOLVE CLASS - 1 OBSERVED SUPPORT COLUMN IN THE BOILER ROOM LOCATED IN THE BASEMENT/CELLAR HAS SEVERE CRACKING., REPAIR AND/REPLACE $1,250 $1,250 May 8, 2025
Jul 17, 2024 39119391H RESOLVE CLASS - 1 OBSERVED ON 07/17/2024 IN THE BASEMENT/CELLAR GAS METER ROOM HAS COMBUSTIBLE STORAGE AND ALSO BEING USED AT AN OFFICE... $1,250 $0 Nov 21, 2024
Jul 17, 2024 39119309J RESOLVE CLASS - 1 AT TIME OF INSPECTION AT ABOVE PREMISE THE TENANT PROTECTION PLAN SUBMITTED INDICATES THAT NO STRUCTUAL WORK IS INCLU... $2,530 $0 Apr 3, 2025
Jul 17, 2024 39119393L RESOLVE CLASS - 1 OBSERVED NO VENTILATION IN THE GAS METER ROOM LOCATED IN THE BASEMENT/CELLAR. AS PER E 4 OF THE FGC GAS METER ROOM SH... $1,250 $0 Nov 21, 2024
Jul 17, 2024 39119392J RESOLVE CLASS - 1 OBSERVED NO SPRINKLER HEAD IN THE COMMERCIAL LAUNDRY ROOM LOCATED IN THE BASEMENT/CELLAR AS PER 903.2.11.13 LAUNDRY D... $2,500 $0 Nov 21, 2024
Jul 17, 2024 39119316H RESOLVE CLASS - 2 AT TIME OF INSPECTION AT ABOVE PREMISE OBSERVED IN UNITS # 804 AND #1204 A/C SPLIT UNITS INSTALLED WITH NO PERMIT ON ... $625 $0 Nov 21, 2024
Jul 16, 2024 39119313M RESOLVE CLASS - 1 AT TIME OF INSPECTION AT ABOVE PREMISE OBSERVED IN UNITS #804 AND #1204 FIRE STOPPING REMOVED ADJACENT TO COMMON AREA... $2,500 $2,500 Nov 21, 2024
Jul 1, 2024 39118107R RESOLVE CLASS - 1 AT TIME OF INSPECTION AT ABOVE PREMISE OBSERVED EXCESSIVE COMBUSTIBLE CONSTRUCTION GARBAGE/DEBRIS IN UNIT #1204 BEING... $2,500 $2,500 Feb 20, 2025
Jun 13, 2024 39116899P RESOLVE CLASS - 1 AT TIME OF INSPECTION AT ABOVE PREMISE OBSERVED WORKERS PERFORMING PLUMBING WORK BEING DONE THROUGHOUT THE ENTIRE UNI... $5,000 $5,000 Feb 5, 2026
Mar 7, 2024 35676661P RESOLVE CLASS - 2 PERMANENT DWELLING CONVERTED FOR OTHER THAN PERMANENT RESIDENTIAL PURPOSES DOB RECORD INDICATES PREMISES TO BE LEGALL... $1,250 $0 Jun 13, 2024
Mar 7, 2024 35676660N RESOLVE CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. LACK OF REQUIRED NUMBER OF MEANS OF EGRESS FOR EVERY FLOOR PER... $2,500 $0 Jun 13, 2024
Mar 7, 2024 35676659X RESOLVE CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. LACK OF A AUTOMATIC SPRINKLER SYSTEM WHERE IS REQUIRED AS PER ... $1,250 $0 Jun 13, 2024
Mar 7, 2024 35676658Y RESOLVE CLASS - 1 BC 907.2.8 FAILURE TO PROVIDE A FIRE ALARM SYTEM FOR TRANSIENT USE AT UNIT 1002 10TH FLOOR). REMEDY: DISCONTINUE ILLE... $2,500 $0 Jan 16, 2025
Feb 7, 2024 39105409J RESOLVE CLASS - 1 CLASS 1: CEASE USE: DOOR RESTRICTOR INOPERATIVE ADJUST/REPLACE LOCK (CU). TO RESTORE SERVICE CONTACT NYCDOB AT EIR@BU... $1,250 $0 Jan 16, 2025
Feb 7, 2024 39105408H RESOLVE CLASS - 1 CLASS 1: CEASE USE: ESCAPE HATCH DOOR MISSING PRESENTING SEVERE SAFETY HAZZARD PROVIDE NEW DOOR (CU). MISSING PANEL O... $1,250 $0 Jan 16, 2025
Jan 23, 2024 39103991P RESOLVE CLASS - 1 CAR CEASE USE CLASS 1.CAR DOOR RESTRICTOR IS NOT WORKING TAMPERED WITH REPAIR,2/M/7 OUT SIDE COMM MISSING PROVIDE,59/... $1,250 $0 Feb 13, 2025
Nov 6, 2023 35656492P RESOLVE CLASS - 2 WORK WITHOUT A PERMIT: NOTED: AT TIME OF INSPECTION, OBSERVED CONSTRUCTION WORK IN PROGRESS ON THE SIX (6) AND EIGHT ... $0 $0 Apr 11, 2024
Jan 7, 2021 35441626N RESOLVE CLASS - 2 WORK WITHOUT A PERMIT.AT THE TIME OF INSPECTION OBSERVED A FULLY COMBUSTIBLE ENCLOSED WOOD FENCE ROOFED STRUCTURE HAS... $1,250 $0 Mar 25, 2021
Apr 24, 2018 35318776P RESOLVE CLASS - 1 FAILURE TO MAINTAIN EXTERIOR BLDG WALL AND APPURTENANCES.NOTED:ON EXP#1 SOUTH ELEVATION;I OBSERVED CRACKED EYEBROW AT... $0 $0 Aug 16, 2018
Apr 24, 2018 35368777M RESOLVE CLASS - 1 FAILURE TO MAINTAIN EXTERIOR BUILDING WALLS AND APPURTENANCES. NOTE:ONEXP1 SOUTH ELEVATION: I OBSERVED CRACKS ON EYEB... $0 $0 Jan 10, 2019
Feb 19, 2004 34426006K RESOLVE Non-Hazardous OPERATION OF A PLACE OF ASSEMBLY W/O A CURRENT PERMIT.PREMISES ARRANG ED FOR OCCUPANCY BY 160 PERSONS(WITH OCCUPANCY ... $500 $0 May 6, 2004
Feb 19, 2004 34426007M RESOLVE Non-Hazardous EXIT DOOR SWINGS AGAINST FLOW OF EGRESS.NOTE: EXIT DOOR IN BASEMENT LEADING TO REAR COURTYARD & SIDEWALK.SWINGS AGAIN... $350 $0 May 6, 2004
Dec 2, 2003 38143736H RESOLVE Non-Hazardous 15M07,03M07,84A07,66P07. 15-INSTALL CERT FRAME IN CAR WITH CERT 03-INSTALL CAPCITY PLAN IN CAB (3000) 84-NO TURN CAR ... $0 $0 Jan 22, 2004
Dec 2, 2003 38143735X RESOLVE Hazardous 84A07,CEASE USE 40D09,44B15,03B07,32B07. 84-CEASE USE UNTIL THIS DEVICE IS TESTED AT 2500 LBS CAPACITY RATED LOAD ACC... $180 $0 Mar 25, 2004
Apr 3, 2000 34244059R RESOLVE Non-Hazardous WORK WITHOUT A PERMIT: WORK NOTED:TWO WINDOW CANOPIES ERECTED APPROX 4'X7' FACES NAMES REMEDY: OBTAIN A PERMIT IF FEA... $2,500 $0 Aug 24, 2000
Jul 16, 1999 38087984N RESOLVE Non-Hazardous 75T,50Y,15B,31Q,62Q. FIVE YEAR TEST TAG NOT STAMP, MAIN MACHINE LEAKING OIL, ADJUST BASEMENT HOISTWAY DOOR TOO MUCH G... $0 $0 Sep 2, 1999
Oct 8, 1998 34160743P RESOLVE Non-Hazardous FAILURE TO FILE A REPORT OF COMPLIANCE W/ LL 16/84 CERTIFYING TO THE INSTALLATION OF REQUIRED FIRE PROTECTION SYSTEMS... $0 $0 Dec 3, 1998
Aug 20, 1997 34161093R RESOLVE Non-Hazardous OCCUPIED CONTRARY TO THAT ALLOWED BY THE CERTIFICATE OF OCCUPANCY #60812 SHOWING CELLAR & 1ST FLOOR AS BOILER ROOM & ... $0 $0 Jan 15, 1998
Mar 8, 1997 34142214K RESOLVE Non-Hazardous FAILURE TO COMPANT AT PERMITTED WORK IN ACCORDIANCE WITH APPLICATE LAWS AND REGULATIONS IN THAT CONSTRUCTION WORK ACT... $350 $0 Apr 24, 1997
Jan 16, 1997 38058436J RESOLVE Non-Hazardous 75U.75-PERFORM & FILE TAG GOV & TOP OF CAR $0 $0 Mar 20, 1997
Jan 16, 1997 38058435H RESOLVE Non-Hazardous 75U.75-PERFORM & FILE TEST &TAG GOV&TOP OF CAR $0 $0 Mar 20, 1997
Jun 26, 1995 38047375L RESOLVE Non-Hazardous 05I,35I,57O,74M,74I,03A.35-REPAIR MTR ROOM WALLS 74-PROVIDE FAN INCAR 74-REPAIR CAR SADDLE 03-FILE & OBTAIN PERMIT FO... $450 $0 Dec 14, 1995
Oct 7, 1994 34115640J RESOLVE Non-Hazardous OCCUPANCY CONTRARY TO THAT ALLOWED BY BUILDING DEPARTMENT RECORDS. LOCATION - 5TH FLOOR-WEST FROM:APT TO:OFFICE USE K... $0 $0 Nov 17, 1994
Jan 28, 1993 38030786P RESOLVE Non-Hazardous 35O,37O,57O,50Y. 74A COMPLY WITH RULE 805.1A ID MACHINES. $0 $0 Mar 11, 1993
Jan 28, 1993 38030787R RESOLVE Non-Hazardous 35O,37O,57O,50Y,06H. 74 COMPLY WITH RULE 803.1A. ID MACHINE. 74B REMOVE ALL UNRELATED WIRING FORM SHAFT. $0 $0 Mar 11, 1993
Jul 9, 1991 38013241K RESOLVE Non-Hazardous 01L,02L $0 $0 Feb 20, 1992