Skip to content

ECB violations

220-224 West 42 Street, Manhattan • Block 01013 • Lot 0042

25 records

Environmental Control Board violations, which carry a hearing and a penalty.

Issued Violation Status Severity Description Penalty Balance due Hearing
Nov 14, 2019 35461784R RESOLVE CLASS - 2 WORK DOES NOT CONFORM TO APPROVED CONST DOCUMENTS AND/OR APPROVED DOCUMENTS. @THE TIME OF MY INSPECTION. IT WAS OBSER... $620 $0 Jan 23, 2020
Nov 14, 2019 35461786K RESOLVE CLASS - 2 BC 3307.6.5.6 SHARP EDGES. @THE TIME OF MY INSPECTION IT WAS OBSERVED AN ACTIVE CONST SITE WITH SIDEWALK SHED ERECTED... $620 $0 Jan 23, 2020
Nov 14, 2019 35461785Z RESOLVE CLASS - 2 POSTING OF UNLAWFUL SIGNS, INFORMATION, PICTORIAL REPRESENTATION, BUSINESS OR ADVERTISING MESSAGES ON PROTECTIVE STRU... $1,250 $0 Jan 23, 2020
Apr 3, 2019 35405202L RESOLVE CLASS - 1 SEC. 3314.4.3 SUPPORTED SCAFFOLD(DAILY LOG-COMPETENT PERSON)AT TIME OFINSPECTION ON A ACTIVE JOBSITE OF A 25 STY BLDG... $2,500 $0 May 30, 2019
Apr 3, 2019 35405200H RESOLVE CLASS - 1 WORK DOES NOT CONFORM TO APPROVED PLANS-SUSPENDED SCAFFOLD AT TIME OF INSPECTION ON A ACTIVE JOBSITE OF A 25 STY BLDG... $2,500 $0 May 30, 2019
Apr 3, 2019 35405201J RESOLVE CLASS - 1 SIDEWALK SHED WHERE REQUIRED AT TIME OF INSPECTION ON A ACTIVE JOBSITE OF A 25 STY BLDG FOR ENTIRE FACADE WORK,IT WAS... $10,000 $0 May 30, 2019
Apr 3, 2019 35405374H RESOLVE CLASS - 1 SEC. 3303.10 OPERATIONS IN OCCUPIED BLDGS. AT TIME OF INSPECTION ON A ACTIVE JOBSITE OF A 25 STY BLDG FOR ENTIRE FACA... $2,500 $0 May 30, 2019
Apr 3, 2019 35405373X RESOLVE CLASS - 1 FAILURE TO HAVE SITE SAFETY MANAGER WHEN REQUIRED AT TIME OF INSPECTION ON A ACTIVE JOBSITE OF 25 STY BLDG FOR(ENPIRE... $10,000 $0 May 30, 2019
Sep 21, 2015 37000080J RESOLVE CLASS - 2 28-317.3 FAILURE TO REGISTER COOLING TOWER. RMDY:COMPLY W/CODE $0 $0 Nov 12, 2015
Feb 12, 2014 38229587K RESOLVE CLASS - 2 80B07,73B10,74B10. 80-PROVIDE PROPER COUNTER WEIGHTS RUNBY.BLOCKING MISSING; 73-74-CHECK ALL CAR & COUNTERWEIGHT NAIL... $0 $0 Apr 3, 2014
Apr 20, 2011 34905911Z RESOLVE CLASS - 1 FAILURE TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY INSTRUCTION OPERATIONS. PARTIAL STOP WORK ORDER ISSUED PURSUA... $2,400 $0 Jun 23, 2011
Mar 22, 2011 34860693N RESOLVE CLASS - 1 FAILURE TO HAVE SITE SAFETY MANAGER OR COORDINATOR PRESENT AS REQUIREDNOTED:APPROX 15 MEN WORKING DOING PROTECTION WO... $2,400 $0 Aug 4, 2011
Oct 31, 2002 34343224P RESOLVE Non-Hazardous ALTERED BUILDING OCCUPIED WITHOUT A VALID CERTIFICATE OF OCCUPANCY.ALT.102189873 REMEDY:OBTAIN VALID C OF O. $2,500 $0 Dec 19, 2002
Oct 31, 2002 34343225R RESOLVE Non-Hazardous OPERATION OF A PLACE OF ASSEMBLY WITHOUT A CURRENT PERMIT. PA102518848REMEDY: OBTAIN A P.A. PERMIT. $2,500 $0 Dec 19, 2002
Sep 10, 2002 38124847R RESOLVE Non-Hazardous 73B07/ (73-B-07) FINALISE EBN 1134-99 $350 $0 Oct 31, 2002
Mar 14, 2001 38114663N RESOLVE Non-Hazardous 73M#. 73M DECICE HAS BEEN REMOVED FILE WITH DEPT OF BUILDING FOR REMOVED. $500 $0 Aug 2, 2001
Mar 14, 2001 38114664P RESOLVE Non-Hazardous 73M# ENTIRE DEVICE REMOVED FILE WITH DEPT OF BUILDINGS FOR REMOVAL $500 $0 Aug 2, 2001
Jul 14, 2000 32019772Z RESOLVE Non-Hazardous 36 36-AERCO BOILER (MODEL G-99-306) NOT REGISTERED WITH NYC DEPARTMENT OF BUILDIGN BOILER INSTALLED WITHOUT WORK PERMIT $250 $0 Sep 7, 2000
Jul 14, 2000 32019773K RESOLVE Non-Hazardous 36 36-AERCO BOILER(MODEL G-99-306) NOT REGISTERED WITH NYC DEPARTMENT OF BUILDINGS BOILER INSTALLED WITHOUT WORK PERMIT $250 $0 Sep 7, 2000
Jul 14, 2000 32019774M RESOLVE Non-Hazardous 36 36-AERCO BOILER (MEDEL G-99-306) NOT REGISTERED WITH NYC DEPARTMENT OF BUILDING. BOILER INSTALLED WITHOTU WORK PERMIT $2,500 $0 Sep 7, 2000
Dec 17, 1997 34160848L RESOLVE Non-Hazardous FAILURE TO PROVIDE EMERGENCY LIGHTIN ON FLOORS:2,3,4,8,17 & 18. FAILURE TO PROVIDE EMERGENCY POWER TO LIGHITN FACILIT... $1,400 $0 Feb 12, 1998
May 30, 1997 34150869L RESOLVE Hazardous FAILURE TO FILE AN AMENDED ROUND REPORT ACCEPTABLE TO THID DEPARTMENT PURSUANT TO RULE R.C.N.Y. 32-03B(5) INDICATING ... $400 $0 Jul 31, 1997
Mar 19, 1996 34131343N RESOLVE Non-Hazardous FAILURE TO PROVID EEMERGENY POWER EXIT LIGHT ON FLOORS 2,3,4,8,17,18 FAILURE TO PROVIDE EMERGENCY POWER TO EXIT DIREC... $800 $0 May 9, 1996
May 6, 1993 38033334H RESOLVE Non-Hazardous 28H 18M 18 PROVIDE MISSING COVERS $100 $0 Jul 1, 1993
Jun 23, 1988 34007953M RESOLVE Non-Hazardous ALTERED BUILDING OCCUPIED AT THE 6TH AND 7TH FLOOR WITHOUT A VALID C OF O. REMEDY: OBTAIN C OF O $250 $0 Jan 13, 1989