ECB violations
264-272 West 47 Street, Manhattan • Block 01018 • Lot 0061
24 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Jun 18, 2026 | 39555702R | ACTIVE | CLASS - 2 | AT THE TIME OF MY INSPECTION I OBSERVED THAT THERE WERE UNAUTHORIZED ADVERTISEMENT ON THE SIDE WALK SHED INSTALLED. | $2,500 | $2,500 | Aug 27, 2026 |
| Oct 20, 2017 | 38257787N | RESOLVE | CLASS - 2 | 52K11/52-K-11-REPLACE ROUGED HOIST ROPES | $250 | $0 | Dec 7, 2017 |
| Feb 8, 2011 | 34879577X | RESOLVE | CLASS - 2 | FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY. NOTED A CELLAR LEVEL 2ND MEANS OF EATING & DRINKING ESTABLISHMENT KN... | $400 | $0 | Mar 31, 2011 |
| Jan 28, 2010 | 34754495N | RESOLVE | CLASS - 2 | FAILURE TO COMPLY W/SELF-CLOSING REQUIREMENTS OF FIRE DOORS. NOTED: MUULTIPLE EXIT DOORS FROM 2ND-4TH FLRS ARE NOT SE... | $500 | $0 | Jan 6, 2011 |
| Jan 28, 2010 | 34754494L | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER, IN THAT ENTIRE PA SPACES SPRINKLER HEADS ARE BEING PARTIALLY OBSTR... | $5,000 | $0 | Jun 9, 2011 |
| Jan 28, 2010 | 34754496P | RESOLVE | CLASS - 1 | WORK W/O PERMITS. WORK NOTED: AT 2ND FLR LEVEL LOCATED IN STAIRWAY "A"EXIST A ROLL DOWN GATE TOTALLY OBSTRUCTING EXIT... | $1,600 | $0 | Jan 6, 2011 |
| Jan 28, 2010 | 34754493J | RESOLVE | CLASS - 2 | WORK DOES NOT CONFORM TO APPROVED PLANS DATED 8.22.08 UNDER PA-1 #101444340 AT 3RD FLR LEVEL A LEGAL STAGE EQUIPPED F... | $0 | $0 | Jan 6, 2011 |
| Jan 28, 2010 | 34754492H | RESOLVE | CLASS - 2 | WORK DOES NOT CONFORM TO APPROVED PLANS. NON-CONFORMING WORK NOTED: AT4TH FLR LEVEL APPROVED PLANS DATED 5.7.08 UNDER... | $0 | $0 | Jan 6, 2011 |
| Jan 28, 2010 | 34754498Z | RESOLVE | CLASS - 1 | SEC. 1004.4;27-534(B). FAILURE TO COMPLY W/'DESIGN OCCUPANT LOAD EXITING FROM MULTIPLE LEVEL REQUIREMENTS'. NOTED: C/... | $0 | $0 | Jan 6, 2011 |
| Jun 25, 2009 | 38203641R | RESOLVE | CLASS - 3 | 68M7.69M7.12Q3.15D6.03D6.53B14.70R9.70R09 MATERIAL STORED IN WALK IN PIT | $500 | $0 | Aug 13, 2009 |
| Aug 12, 2007 | 34553766P | RESOLVE | Hazardous | REQUIRED MEANS OF EGRESS OBSTRUCTED. NOTE AT 3RD FL METAL BARRIER AND METAL COAT RACKS OBSTRUCTING EXIT PASSAGEWAY. R... | $400 | $0 | Oct 11, 2007 |
| Aug 12, 2007 | 34553765N | RESOLVE | Hazardous | OPERATION OF PA W/O A CURRENT PERMIT. NOTE PERMITS #S 101444359 2ND FLR. 3RD FLR #101444340 & 4TH FLR #102796351. ALL... | $500 | $0 | Oct 11, 2007 |
| Aug 31, 2005 | 34491344Y | RESOLVE | Non-Hazardous | FAILURE TO PROVIDE CONTRACTOR'S SIGN. REMEDY: PROVIDE SIGN. | $5,000 | $0 | Nov 10, 2005 |
| Feb 10, 2005 | 34452238Z | RESOLVE | Hazardous | FAILURE TO MAINTAIN EXTERIOR BUILDING WALL:AT SOUTH ELEVATION WALL PARAPIT LEVEL AND AT VARIOUS LOCATION ON SAID WALL... | $2,500 | $0 | Mar 31, 2005 |
| Oct 28, 2002 | 38125921K | RESOLVE | Non-Hazardous | 37G12-40B14-54D06-35O02-73O02-46M07-31Q03-57O02-14M07. REPLACE #4 & 5 FUSES 40- SEAL GOVERNOR 54-GROUND CABLE 73-CLEA... | $0 | $0 | Dec 12, 2002 |
| Jun 9, 2002 | 34326127Z | RESOLVE | Non-Hazardous | OPERATION OF A PUBLIC ASSEMBLY WITHOUT A CURRECT PERMIT. PLACE OF ASSEMBLY PERMIT. 101444359 HAS EXPIREDON 5/04/02 RE... | $100 | $0 | Jul 25, 2002 |
| Feb 12, 1999 | 34205619Y | RESOLVE | Non-Hazardous | NO EQUIPMENT USE PERMITS. NOTED: 2 "TRANE" TYPE A/C UNITS MOUNTED ON DUNNAGE AT ROOF LEVEL OF PREMISES. REMEDY: OBTAI... | $400 | $0 | May 17, 2001 |
| Nov 19, 1997 | 38066885P | RESOLVE | Non-Hazardous | 50Y,35O,35M,30M,25B, 50-SEAL AND CLEAN MACHINE 35-CLEAN MACHINE ROOM REMOVE MATERIAL 35-INSTALL LOCK ON ROOM DOOR AND... | $0 | $0 | Jan 22, 1998 |
| May 6, 1997 | 34152374Z | RESOLVE | Hazardous | FAILURE TO MAINTAIN EXTERIOR BUILDING WALL. MISSING METAL CORNICE ACROSS ENTIRE FRONT.CORRODED & BROKEN CORNICE AT SO... | $0 | $0 | Mar 11, 1998 |
| Jun 19, 1996 | 34137896K | RESOLVE | Hazardous | FAILURE TO MAINTAIN EXTERIOR BUIDLING WALL MISSING METAL CORNICE ACROSS ENTIRE FRONT. CORRODED AND BROKEN CORNICE AT ... | $1,000 | $0 | Feb 19, 1998 |
| Aug 24, 1995 | 34128888X | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN DEFECT NOTED: HOLES THROUGHOUT PARAPET WALL ABOVE FRONT ENTANCE. WEST SIDE. REMEDY: MAKE ALL REPA... | $0 | $0 | Dec 28, 1995 |
| Jun 14, 1995 | 38050141X | RESOLVE | Non-Hazardous | 35D,46H,50Y,50F,28H,10R,73O. 74A)PERFORM 5 YEAR SAFETY TEST AND FILE ELV3 FORM.74B)CLEAN BRAKE PULLEY + CHANGE OIL SO... | $200 | $0 | Sep 21, 1995 |
| Feb 1, 1994 | 34101423X | RESOLVE | Non-Hazardous | FAILURE TO FILE A REPORT OF COMPLIANCE WITH LOCAL LAW 16/84 CERTIFYINGTOT HE INSTALLATION OF REQUIRED FIRE PROTECTION... | $200 | $0 | Mar 24, 1994 |
| Oct 30, 1989 | 34033810Y | RESOLVE | Hazardous | FAILURE TO HAVE APPROVED PA PLAN AVAILAVLE FOR INSPECTION PANIC HARDWARE INOPERATIVE AT 2 MEANS OF EGRESS BASEMENT. R... | $175 | $0 | Feb 1, 1990 |