300-320 West 44 Street, Manhattan
Manhattan • Block 01034 • Lot 0037 • Zip: 10036
Condition
What the city currently has open against this building, counted from its own records.
Address
Land use and zoning
Building
Latest assessment
Neighborhood
The area this lot falls inside, and the commute Hoodkit measures from it.
Getting around
Estimated 3 days ago- Times Square 17 min 10 walking, 7 riding
- Penn Station 18 min 10 walking, 8 riding
- Grand Central 25 min 10 walking, 15 riding
- Union Square 28 min 10 walking, 18 riding
- Fulton Street 30 min 10 walking, 20 riding
- Downtown Brooklyn 35 min 10 walking, 25 riding
Around this address
Transit and places within 0.5 miles of the lot.
Getting out
Subway
Railroad
Ferry
Bus
Citi Bike
Places nearby
Gallaghers Steakhouse
Iconic steakhouse offering classic cuts & raw bar items in renovated digs with red banquettes.
Elder
No description yet
Le Bernardin
No description yet
Chalong
No description yet
Los Tacos No. 1
Experience the authentic flavors of Mexico at Los Tacos No. 1! Located in the heart of NYC, enjoy hand-pressed tortil...
Sullivan Street Bakery
No description yet
Din Tai Fung
Chinese restaurant
Danji
Upscale creative Korean small plates, cocktails & an emphasis on organic/sustainable ingredients.
Activity
Sales, filings, permits and violations from every dataset, in one order.
2026
-
HPD violation May 8, 2026
Class A
(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION ...
2025
-
HPD violation Jun 13, 2025
Class A
(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION ...
2024
-
DOB violation Nov 13, 2024
AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
-
CLASS - 1
: FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. SERVICE ELEVATOR EQUIPMENT AS PER BC3001.2 & 27-987. UPON IN...
2023
-
DOB violation Dec 1, 2023
EGRADE-FAILURE TO POST ENERGY GRADE/SCORE NONE
FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3
-
HPD violation Nov 15, 2023
Class I
§27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27...
2022
-
HPD violation Nov 3, 2022
Class I
§27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27...
-
HPD violation Mar 10, 2022
Class A
(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION ...
2021
-
DOB violation Aug 2, 2021
BENCH-FAILURE TO BENCHMARK NONE
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
-
DOB violation Jun 2, 2021
BENCH-FAILURE TO BENCHMARK NONE
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
-
HPD violation Apr 20, 2021
Class I
§27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27...
-
DOB violation Mar 10, 2021
E-ELEVATOR ELEVATORREQUIRED
-
DOB violation Mar 10, 2021
E-ELEVATOR ELEVATORREQUIRED
-
Alteration Type II
INSTALLATION OF AN ADT ACCESS SYSTEM ON THE ROOF AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLI...
2019
2018
-
Alteration Type II
FILING A FIRE SUPPRESSION SYSTEM ONLY. NO CHANGE IN USE EGRESS OR OCCUPANCY
2017
-
CLASS - 2
FAILURE TO FILE ANNUAL CERTIFICATION THAT COOLING TOWER 100001258 HAS BEEN INSPECTED,TESTED,AND DISINFECTED AND THAT ...
-
CLASS - 1
100X10 EMERGENCY BRAKE DOES NOT MECHANICALLY WORK. HAZARDOUS CONDITION..... IF MAIN BRAKE FAILS UNIT CAN SLID BACKWARDS.
-
Alteration Type II
FILING HEREWITH MODIFICATIONS OF EXISTING SPRINKLER SYSTEM TO ALLOW FOR FUTURE TENANT WORK. IN CONJUNCTION WITH ALT 1...
-
CLASS - 2
1L10,2L10 IN CAR ALARM BELL NOT WORKING. NO BELL RINGS WHEN IN CAR STOP SWITCH IS ENGAGED.
-
Alteration Type I
FILING HEREWITH SUBSEQUENT MECHANICAL AND PLUMBING WORK ASSOCIATED WITH NEW RETAIL STORE. WORK INCLUDES REMOVAL OF KI...
2016
-
Alteration Type II
FILING HEREWITH MODIFICATIONS OF EXISTING FIRE ALARM SYSTEM TO ALLOW FOR FUTURE TENANT WORK. IN CONJUNCTION WITH ALT ...
-
Alteration Type II
FILING HEREWITH FOR SPRINKLER MODIFICATIONS ASSOCIATED WITH PHASE 2 (GUEST ROOMS) AS PER PLANS FILED HEREWITH. NO CHA...
2014
2011
-
CLASS - 2
15M07,60L11 15M07-PROVIDE CERTIFICATE IN FRAME 60L11-LIGHTING MACHINE SPACE REPLACE LIGHTS WHERE NEEDED.
2010
-
CLASS - 2
SEC. 3307.4. FAILURE TO PROVIDE REQUIRED WARNING SIGNS & SAFETY DEVICES. NOTED AT TIME OF INSPECTION ON ACTIVE JOB SI...
2007
2003
The most recent 6 events from each dataset, so no one source takes the axis. Each tab holds the full record.
Property Contacts
Contact information aggregated from multiple government sources
Registration Contracts
Contact information from multiple dwelling registrations
Building Permits
Owner information from Department of Buildings filings
Deed Records
Parties from ACRIS deed and mortgage records
Property Records
Owner information from assessment and PLUTO records