Skip to content

ECB violations

300 West 46 Street, Manhattan • Block 01036 • Lot 0036

46 records

Environmental Control Board violations, which carry a hearing and a penalty.

Issued Violation Status Severity Description Penalty Balance due Hearing
Aug 5, 2025 39156113K RESOLVE CLASS - 2 AT APT # 2J WOOD FLOOR SHAKING & VIBRATINGON IN LIVING ROOM. EXHAUST SYSTEM ATTACHED TO UNDERNEATH APT 2J FLOOR IN CO... $0 $0 Nov 20, 2025
Sep 25, 2024 39125820H ACTIVE CLASS - 2 T TIME OF INSPECTION OBSERVED APT # 2J WOOD FLOOR SHAKING & VIBRATING ON LIVING ROOM. ALSO OBSERVED FIRE SUPPRESSION ... $625 $0 Jan 9, 2025
Oct 24, 2023 39097815H ACTIVE CLASS - 1 CEASE USE (3) DUNKIRKGAS BOILERS MODEL #WPSB-80, DUE TO HAZARDOUS CONDITION, FOUND SAFETY RELIEF VALVES (80 PSI) EXCE... $1,250 $0 Dec 28, 2023
Jan 19, 2021 39035064M RESOLVE CLASS - 1 R T S. ELEVATOR IN BUILDING OUT OF SERVICE, UP ON INSPECTION THE DEVICE IS FOUND TO BE OUT OF SERVICE , REPAIR AND RE... $1,250 $0 Aug 19, 2021
Jul 24, 2020 39025904R RESOLVE CLASS - 1 CLASS 1 NO DLM INSTALLED IN THIS CONTROLLER AS MANDATED BY 3.10.12 OF APPENDIX K3 OF THE 2014 NYCBC. REMEDY; FILE APP... $1,250 $0 Sep 10, 2020
Jan 21, 2020 38273040P RESOLVE CLASS - 1 97X10: (RESTORE TO SERVICE) $1,250 $0 Sep 17, 2020
Mar 3, 2017 38251943Z RESOLVE CLASS - 2 71B16 PIT LIGHT NOT ABLE TO REACH UNLESS YOU CLIMB IN PIT. RELOCATE TOP OF STOP SWITCH. $250 $0 Apr 20, 2017
Nov 7, 2016 38250972N RESOLVE CLASS - 1 97X10. FAILURE TO MAINTAIN BLG IN CODE COMPLIANT MANNER SERVICE EQUIP MENT ELEVATOR AS PER BC 3001.2 AND 27-987. DOB ... $250 $0 Dec 22, 2016
Aug 8, 2016 38244079J RESOLVE CLASS - 2 02B10 OUTSIDE EMERGENCY PHONE VOLUME VERY LOW, VERY DIFFICULT TO HEARREPAIR. $250 $0 Sep 22, 2016
Jul 26, 2016 38244245X RESOLVE CLASS - 1 97X10. FAILURE TO MAINTAIN BLDG IN CODE COMPIANT MANNER, SERVICE EQUIPELEVATOR AS PER BC3001.2 & 27-987. DOB RECORDS ... $1,000 $0 Sep 15, 2016
Apr 22, 2016 38241812J RESOLVE CLASS - 1 05M07,02X10,29D06,40B09,16D06,57BB07,71M07,61B07. 05M-ZONE RESTRICTOR PARTS MISSING,PROVIDE TO WORK AS PER CODE; 02X-... $1,000 $0 Jun 9, 2016
Dec 9, 2014 38234375P RESOLVE CLASS - 2 02L10,02L10,42M11,48B13. 02L10-ALARM BELL TO WORKING: REMEDY REPAIR; 2L10-PHONE NOT WORKING; REMDY: REPAIR; 42M11-CON... $250 $0 Jan 29, 2015
Nov 12, 2014 35153241X RESOLVE CLASS - 2 OCCUPANCY CONTRARY TO THAT ALLOWED BY THE CERT OF OCCUPANCY OR BLDG DEPT RECORDS DOB & HPD RECORDS INDICATED PREMISES... $1,200 $0 Jan 8, 2015
Nov 12, 2014 35153242H ACTIVE CLASS - 2 WORK W/O A PERMIT.WORK NOTED:@ 3RD FL UNIT"3J"INSTALLED WATER & WASTE LINE FOR RESIDENTIAL SINK @ KTICHEN.INSTALLED E... $800 $0 Jan 8, 2015
Jun 10, 2013 38226611H RESOLVE CLASS - 2 B251:100Y10,70O02.100Y:REPAIR PISTON OIL LEAK.70O:REMOVE OIL FROM PIT. $2,500 $0 Jul 25, 2013
Apr 15, 2013 38225869K RESOLVE CLASS - 2 16B7,97B10,67B10,70O2,68B7. 16B- PROVIDE LUBRICANT ON BASEMENT HOISTWAY DOOR ROLLERS. 97B- ENTIRE DEVICE VIBRATES DUR... $0 $0 May 30, 2013
Mar 28, 2012 38221066Z RESOLVE CLASS - 2 02X10,16D06,99BB05. 16D- SECURE ALL ASTRAGALS FOR HOISTWAY BIPARTING DOORS. $500 $0 Sep 27, 2012
Dec 2, 2011 38219238N RESOLVE CLASS - 2 98BB05 99B05 100B09 48M11 100D06 100B-CAN RIDE DURING MOTION SOME VIBRATION BUMPY RIDE 48M-REPLACE VENT CAP ON PUMP U... $500 $0 Feb 23, 2012
Sep 7, 2011 38216151R RESOLVE CLASS - 2 98BB05,25M07,39R07,05X10,#B10. 39R- TOP OF CAR EMERG EXIT COVER PROVIDE WING NUTS. 05X- ZONE RESTRICTOR. #B- BUMP IN ... $500 $0 Dec 1, 2011
Sep 2, 2011 38217916Y RESOLVE CLASS - 1 26N10,100M01,100BB09,40B07,68M07,69M07,40X10. 26N10-TOP OF CAR MICRO SWITCH BY PASSED WITH ELECTRICAL TAPE CEASE USE ... $1,000 $0 Feb 23, 2012
Jul 12, 2010 34851873X RESOLVE CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. NOTED THE FOLLOWING CONDITIONS. AN INSPECTION OF APARTMENT 5L ... $1,000 $0 Dec 17, 2010
Mar 23, 2010 38209934H RESOLVE CLASS - 2 70O9.71X10.26D6.100Y10.70O9 HYDRAULIC OIL FROM PIT 100Y10 PISTON APPEARS TO BE LEAKING REPAIR DEVICE $2,500 $0 Sep 2, 2010
Mar 17, 2009 38202202K RESOLVE CLASS - 2 97X10.40O02.68M07.98BB05.100BB05.71I11.10M07.10H11.97X10 SHUT DOWN DURING INSPECTION 95BB05 ROPED HYDRO 100BB05 2YR $500 $0 Sep 10, 2009
Feb 4, 2009 38200531M RESOLVE CLASS - 2 100V05.48Y10.34Y10.70Y02.71I10.10H10.39M07.42B07.97#10.100U05 FILE & PERFORM 2YR TEST PRESSURE TEST 48Y10 REPAIR OIL ... $500 $0 Dec 11, 2009
Jan 20, 2009 38200406N RESOLVE CLASS - 2 99BB05.42G11.35Q11.70O02.71I11.16B07.99BB05 HYDRALLIC TEST TAG HAS EXPIRED PERFORM & FILE TEST 42G11 REPLACE FUSE AT ... $500 $0 Dec 11, 2009
Mar 15, 2007 38165208L RESOLVE Non-Hazardous 47M7/84M11/38L10/84D6/47-M-MISSING SEAL ON MANUEL LOWERING VALVE.PROVIDE SEAL.84-M-REPLACE MISSING DUST COVER AT MEZZ... $180 $0 May 10, 2007
Jul 27, 2006 38160776R RESOLVE Non-Hazardous 02X10/01X10/66Y02 02-ALARM BELL-INOPERATIVE 01-EMERGENCY STOP SWITCH ALARM-INOPERATIVE WHEN PULLED. $0 $0 Sep 14, 2006
Jul 26, 2006 38160477R RESOLVE Non-Hazardous 84N10 CEASE USE (84) ENTIRE SAFETY CIRCUIT JUMPED OUT: REPAIR PROBLEM IN SAFETY CIRCUIT. CALL 212-566-5542 TO RETURN ... $500 $0 Sep 14, 2006
Jul 26, 2006 38160495K RESOLVE Non-Hazardous 41N10 ENTIRE SAFETY CIRCUIT IS JUMPED. REPAIR PROBLEM IN SAFETY CIRCUIT CALL 212-566-5542 TO RETURN TO SERVICE. $0 $0 Sep 21, 2006
Nov 29, 2005 38155868H RESOLVE Non-Hazardous 03B10/47BB05-03-B-VIBRATION COMING FROM UP & DOWN TRAVEL.47-BB-2 YEAR PRESSURE TEST $0 $0 Jan 19, 2006
Oct 12, 2005 38154923R RESOLVE Non-Hazardous 47B01/ 60M07/ 84M07/ (47) ADJUST PUMP UNIT ELEVATOR JUMPING & BOUNCING(60) PROVIDE COMPANY STICKER MAIN LINE SWITCH. ... $2,500 $0 Dec 1, 2005
Sep 28, 2005 38155068J RESOLVE Non-Hazardous 13X10/38X10/66M07/#L01/*L10. (13)EMERGENCY LIGHTS INOPERATIVE. (3)TDC LIGHTS INOPERATIVE. (66)SUMP PUMP COVER IN PIT ... $2,500 $0 Nov 17, 2005
May 10, 2005 38152458L RESOLVE Non-Hazardous 10H10 $0 $0 Jun 30, 2005
Dec 19, 2003 38143830Y RESOLVE Non-Hazardous CEASE USE. 50X10, 44U15,38O02. 50- DEVICE RUNS WITH SLACK CABLE SWITCH OPEN. CEASE USE OF DEVICE UNTIL REPAIRED. CALL... $1,250 $0 Feb 5, 2004
May 28, 2003 38138311X RESOLVE Non-Hazardous 81-BB-5. PERFORM A FILE FOR 5 YEAR TEST $180 $0 Jul 17, 2003
May 27, 2003 38138308P RESOLVE Non-Hazardous CEASE USE. 47N11, 47-N-11 SLACK CABLE SWITCH BYPASSED- CALL THIS DEPARTMENT WHEN REPAIRS ARE MADE SO PROPER INSPECTIO... $500 $0 Jul 17, 2003
Feb 5, 2001 38111206Y RESOLVE Non-Hazardous 47H15, 74B09, 74O02. 47H15-GOVERNOR CABLE MUST BE SHORTEN 1/2" CLEARING BEFORE TOUCHING FL. 74B09- BUMPING & BANGING ... $180 $0 Mar 22, 2001
Sep 9, 1998 34181220Z RESOLVE Non-Hazardous FAILURE TO MAINTAIN BUILDING. FIRE RATED CEILING IS MISSING AT CELLAR FROM FRONT TO REAR. REMEDY: PROVIDE A FIRE RATE... $2,500 $0 Dec 17, 1998
Mar 28, 1997 34152242R RESOLVE Hazardous FAILURE TO PRERORM ADEQUATE HOUSEKEEPING IN THAT ACCUMILATION OF DEBRIS THROUGHOUT 1 FLOOR. REMEDY: PREFORM HOUSEKEEP... $0 $0 Jun 12, 1997
Mar 3, 1993 34075671Z RESOLVE Hazardous SIDEWALK SHED DOES NOT MEET DEPT OF BUILDINGS CODE SPECIFICATIONS IN THAT THE SHED DOESNOT CONFORM TO LOCAL LAW 33/91... $170 $0 Oct 14, 1993
Mar 3, 1993 34075670R RESOLVE Non-Hazardous FAILURE TO OBTAIN A PERMIT FOR A SIDEWALK SHED. SIDEWALK SHED IS IN PLACE. REMEDY: OBTAIN NECESSARY PERMITS AS PER DE... $350 $0 May 27, 1993
Nov 14, 1989 34034304X RESOLVE Hazardous FAILURE TO MAINTAIN INTERIOR HAZARDOUS WOODEN STAIR STRINGER BROKEN MISSING & DEFECTIVE CAUSING A HAZARDOUS CONDITION... $0 $0 Jan 18, 1990
Nov 14, 1989 34034305H RESOLVE Hazardous FAILURE TO MAINTAIN INTERIOR HAZARDOUS NOTED FIRE RATE D PUBLIC HALLWAY CEILING AND PARTITIONS BROKEN MISSING AND DEF... $0 $0 Jan 18, 1990
Aug 10, 1989 34023789J RESOLVE Hazardous FAILURE TO MAINTAIN LOOSE BROKEN & MISSING STEPS IN THE STAIRWAY LEADING TO THE BASEMENT REMEDY MAKE ALL NECESSARY RE... $0 $0 Nov 2, 1989
Aug 10, 1989 34023788H RESOLVE Hazardous FAILURE TO MAINTAIN FIRE REATING MISSING IN VARIOUS LOCATIONS IN THE CEILING BACK OF STORE. REMEDY MAKE ALL REPAIRS T... $0 $0 Nov 2, 1989
Mar 23, 1989 34021708J RESOLVE Non-Hazardous FAILURE TO MAINTAIN DEFECTS IS CEILING AT PUBLIC HALWAY 3RD CRACK AND MISSINT STAIRS BET 3 & 4 FLOORS LOOSE BROKEN AN... $0 $0 Sep 21, 1989