ECB violations
315 West 53 Street, Manhattan • Block 01044 • Lot 0024
15 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Jun 4, 2026 | 39555072L | ACTIVE | CLASS - 1 | AT THE TIME OF MY INSPECTION OBSERVED CS FAILED TO PERFORM DUTIES PER CODE, NO PLANS WAS PROVIDED UPON REQUEST OF COM... | $10,000 | $10,000 | Mar 8, 2027 |
| Jun 4, 2026 | 39555055J | ACTIVE | CLASS - 1 | AT THE TIME OF MY INSPECTION OBSERVED INADEQUATE SHORING IN CELLAR LEVEL. UPON REQUEST NO DETAILS FOR INADEQUATE SHOR... | $2,500 | $2,500 | Aug 13, 2026 |
| Jun 4, 2026 | 39555067R | ACTIVE | CLASS - 1 | AT THE TIME OF MY INSPECTION OBSERVED STEEL BEAM ABOVE WINDOW FRAME INSTALLED WITHOUT DESIGN DRAWINGS@2ND LEVEL, NO D... | $2,500 | $2,500 | Aug 13, 2026 |
| Jun 4, 2026 | 39555068Z | ACTIVE | CLASS - 1 | AT THE TIME OF MY INSPECTION OBSERVED COLD FORM STEEL WITHOUT BLOCKING OR STRAP BRIDGING ON FLOORS 2,3,4,5. NO DESIGN... | $2,500 | $2,500 | Aug 13, 2026 |
| Apr 16, 2026 | 39553153Y | ACTIVE | CLASS - 2 | AT THE TIME OF INSPECTION OF A 5-STORY BUILDING, A SIDEWALK SHED WAS IN PLACE CONTRARY TO APPROVED DRAWINGS. AT EXP# ... | $1,280 | $1,280 | Jun 25, 2026 |
| Apr 16, 2026 | 39553154X | ACTIVE | CLASS - 2 | BC 3305.3.3.3: AT THE TIME OF INSPECTION OF A 5-STORY BUILDING, COLD-FORMED STEEL WORK WAS OBSERVED. UPON REQUEST, NO... | $2,530 | $2,530 | Jun 25, 2026 |
| Jan 30, 2026 | 39549679R | RESOLVE | CLASS - 2 | 3314.3.4 AT TIME OF INSPECTION OF A 5 STORIES BUILDING UNDER STRUCTURAL PERMIT I OBSERVED SUPPORTED SCAFFOLD INSTALLE... | $2,500 | $2,500 | Dec 3, 2026 |
| Jan 30, 2026 | 39549678P | RESOLVE | CLASS - 2 | AT TIME OF INSPECTION OF A 5 STORIES BUILDING UNDER STRUCTURAL PERMIT I OBSERVED SUPPORTED SCAFFOLD INSTALLED ON TOP ... | $0 | $0 | May 7, 2026 |
| Jul 23, 2025 | 39542704H | RESOLVE | CLASS - 2 | DURING MY INSPECTION OF AN ACTIVE ALT SITE, I REVIEWED THE SITE HISTORY. I OBSERVED THAT THE PERMIT HOLDER HAS FAILED... | $3,125 | $3,125 | Oct 2, 2025 |
| Jul 23, 2025 | 39542705J | RESOLVE | CLASS - 2 | DURING MY INSPECTION OF AN ACTIVE ALT SITE, I REVIEWED THE SITE HISTORY. I OBSERVED THAT THE PERMIT HOLDER HAS FAILED... | $3,125 | $3,125 | Oct 2, 2025 |
| May 28, 2025 | 39540770R | RESOLVE | CLASS - 1 | AT TIME OF INSPECTION OBSERVED ACTIVE UNDERPINNING ACTIVITIES. UPON INSPECTING APPROVED PLANS NOTICE WORK OUT OF SEQU... | $6,250 | $6,250 | Oct 1, 2026 |
| May 28, 2025 | 39540771Z | RESOLVE | CLASS - 1 | AT TIME OF INSPECTION OBSERVED ACTIVE UNDERPINNING ACTIVITIES. EXCAVATION WORK IS SUBSTANTIALLY COMPLETED. UPON FURTH... | $6,250 | $6,250 | Oct 1, 2026 |
| May 27, 2025 | 39540683Z | RESOLVE | CLASS - 1 | AT TIME OF INSPECTION OBSERVED ACTIVE CONSTRUCTION SITE CURRENTLY DOING UNDERPINNING. SAFETY VIOLATING CONDITIONS FOU... | $12,500 | $12,500 | Jun 11, 2026 |
| May 27, 2025 | 39540684K | RESOLVE | CLASS - 2 | AT TIME OF INSPECTION OBSERVED ACTIVE UNDERPINNING WORK ON SITE. UPON REQUESTING THE FOLLOWING DOCUMENTS SOE/UNDERPIN... | $3,125 | $3,125 | Oct 1, 2026 |
| May 27, 2025 | 39540685M | RESOLVE | CLASS - 1 | AT TIME OF INSPECTION OBSERVED ACTIVE CONSTRUCTION ACTIVITIES. UPON REQUESTING PRE-SHIFTS CP PROVIDED A FOLDER OF INA... | $12,500 | $12,500 | Oct 1, 2026 |