544-550 West 43 Street, Manhattan • Block 01071 • Lot 0054

42 records

Environmental Control Board violations, which carry a hearing and a penalty.

Issued Violation Status Severity Description Penalty Balance due Hearing
Sep 23, 2022 39070688Y RESOLVE CLASS - 1 CAR CEASE USE CLASS1 DOOR ZONE RESTRICTOR NOT WORKING TAMPERED WITH OR DISABLED. $0 $0 Nov 10, 2022
Mar 26, 2020 39020469Z ACTIVE CLASS - 1 EXPIRED FIRE EXTINGUISHER IN MOTOR ROOM, PHONE NOT WORKING,NO DOOR LOCK MONITORING INSTALLED IN CONTROLLER AS MANDATE... $1,250 $1,250 Apr 15, 2021
Mar 26, 2020 39020470X ACTIVE CLASS - 1 EXPIRED FIRST EXTINGUISHER, PHONE NOT WORKING,NO DOOR LOCK MONITORING INSTALLED IN CONTROLLER AS MANDATED IN 3.10.12 ... $1,250 $1,250 Apr 15, 2021
Mar 26, 2020 39020471H ACTIVE CLASS - 1 INSUFFICIENT FIRE EXTINGUISHER IN MOTOR ROOM, PHONE NOT WORKING, NO DOOR LOCK MONITORING INSTALLED IN CONTROLLER AS M... $6,250 $6,250 Jan 7, 2021
May 17, 2002 34278000H RESOLVE Non-Hazardous WORK W/O PERMIT UPON INSPECTION AT THE ABOVE PROPERTY PIPE SCAFFOLD WAS INSTALLED IS NO PERMIT ISSUED STOP ALL WORK O... $800 $0 Jul 3, 2003
May 17, 2002 34277999H RESOLVE Non-Hazardous NO DESIGN FRAWING UPON INSPECTION AT THE ABOVE PROPERTY SACFFOLD WAS INSTALLED UP TO 19TH FLOOR AND THERE IS NO DESIG... $500 $0 Jul 3, 2003
Feb 26, 2002 34314223K RESOLVE Hazardous APPROVED PLANS NOT AVAILABLE FOR INSPECTION AT TIME OF INSPECTION CONTINUOS WINDOW FOR EAST SIDE 21 TO 22ND FL WAS BE... $500 $0 Jul 3, 2003
Feb 8, 2002 34288225H RESOLVE Hazardous INSUFFICIENT CONTAINERS PROVIDED FOR THE STORAGE OF GARBAGE AND DEBRIS AT TIME OF INSPECTION DEBRIS UN COMBUSTIBLE MA... $500 $0 Jul 3, 2003
Aug 7, 2001 34298528Y RESOLVE Hazardous FAILURE TO SAFEGUARD PUBLIC & PROPERTY AT TIME OF INSPECTION BRICK WORK IN PROGRESS ON FLOOR BRICKERS HANGING SCAFFOL... $5,000 $0 Nov 1, 2001
Jul 10, 2001 34263232P RESOLVE Non-Hazardous FAILURE TO CARRY OUT PERMITTED WORK IN ACCORDANCE WITH APPLICABLE LAWS & REGULATIONS IN THE CONSTRUCTION ACTIVITIES A... $0 $0 Nov 1, 2001
May 11, 2001 34288588R RESOLVE Hazardous HORIZONTAL NETS NOT INSTALLED AS PER MANUFACTURES RECOMEDATION UPON INSPECTION OF SITE AT ABOVE ADDRESS HORIZONTAL SA... $1,250 $0 Jul 3, 2003
May 11, 2001 34288587P RESOLVE Hazardous RESHORES WITHIN 10 FT OF FACADE AT TIME OF INSPECTION RESHORES @ 20TH FLOOR WERE NOT SECURED REMEDY: SECURES RESHORES... $500 $0 Jul 3, 2003
May 11, 2001 34288589Z RESOLVE Hazardous HORIZONTAL NETS NOT INSTAALED AS PER MANUFACTURES RECOMMENDATION: UPON INSPECTION OF SITE AT ABOVE ADDRESS HORIZONTAL... $1,250 $0 Jul 3, 2003
May 8, 2001 34277546P RESOLVE Hazardous HORIZONTAL SAFETY NETTING NOT PROVIDED.UPON INSPECTION OF ABOVE ADDRESS WORK STRIPPING OF CONCRETE FORMS WAS IN PROGR... $1,250 $0 Jul 3, 2003
May 1, 2001 34277494M RESOLVE Hazardous FAILURE TO PROVIDE EMERGNECY LIGHTING OR DEFECTIVE OR MISSING; UPON INSPECTION AT ABOVE PROPERTY,LIGHTING WAS DEFECTI... $0 $0 Jul 3, 2003
Apr 20, 2001 34277486M RESOLVE Hazardous CONCRETE FORMS NOT JOINED PROPERLY AS PER DRAWING.UPON INSPECT. AT SITE AT ABOVE ADDRESS A CONCRETE FORM BLOW-OUT OCC... $500 $0 Jul 3, 2003
Apr 20, 2001 34277487Y RESOLVE Hazardous HORIZONTAL SAFETY NETTING NOT PROVIDED.UPON INSPECTION AT THE ABOVE PROPERTY.HORIZONTAL NETS WERE NOT PROVIDED ON THE... $500 $0 Jul 3, 2003
Apr 3, 2001 34277684N RESOLVE Hazardous SAFETY NETTING DAMAGED/OR BROKEN UPON INSPECTION PREMISES,VERTICAL OR PERIMETER SAFETY NETTING IS NOT SECURED TO THE ... $2,500 $0 Jun 21, 2001
Mar 13, 2001 34277183P RESOLVE Non-Hazardous WORK WITHOUT PERMIT UPON INSPECTION OF ABOVE PREMISES STANDPIPE SYSTEM WAS BEING INSTALLED FROM 1ST TO 12TH FL DEPT R... $500 $0 Jul 3, 2003
Feb 20, 2001 34277677P RESOLVE Hazardous VERTICAL SAFETY NETTING NOT PROVIDED.AT TIME OF INSEPCTION AT THE ABOVE ADDRESS,VERTICAL NETTING AT 8FL,WAS NOT TIED ... $1,250 $0 Jul 3, 2003
Feb 20, 2001 34277676N RESOLVE Hazardous WEDGES USED IN RESHORES WITHIN 10FT OF FACADE:AT TIME OF INSPECTION AT ABOVE PROPERTY WEDGES USED IN RESHORES ON FL 6... $500 $0 Jul 3, 2003
Feb 20, 2001 34277678R RESOLVE Hazardous NO SIDEWALK SHED OVERHEAD PROTECTION GOING INTO BLDG AT TIME OF INSPECTION THE 12FL WAS BEING FRAMED AND NO OVERHEAD ... $2,000 $0 Jul 3, 2003
Feb 6, 2001 34269097Z RESOLVE Hazardous WEDGES USED IN RESHORES WITHIN 10 FEET OF FACADE AT TIME OF INSPECTION AT ABOVE PREMESIS THERE WAS A TOTAL OF 15 WEDG... $500 $0 Jul 3, 2003
Feb 6, 2001 34269096R RESOLVE Hazardous FAILURE TO PROVIDE HANDRAILS ON STAIRWELL UPON INSPECTION AY ABOVE PREMISES. THERE WAS NO HANDRAILS ON STAIRS FROM FI... $1,250 $0 Jul 3, 2003
Feb 6, 2001 34269098K RESOLVE Hazardous HORIZONTAL SAFETY NETTING NOT PROVIDED , AT TIME OF INSPECTION THERE WAS NO HORIZONTAL SAFETY NETTING BUILDING HAS RE... $2,500 $0 Jul 3, 2003
Jan 8, 2001 34262906H RESOLVE Non-Hazardous FAILURE TO CARRY OUT PERMITTED WORK IN ACCORDANCE WITH APPLICABLE LAWS AND REGULATIONS IN THAT CONSTRUCTION ACTIVITIE... $0 $0 Aug 7, 2003
Jun 1, 2000 34234072M RESOLVE Non-Hazardous FAILURE TO HAVE SITE SAFETY MANAGER PRESENT AT SITE AT TIME OF INSPECTION.THERE IS NO SITE SAFETY MANAGER PRESENT.POS... $5,000 $0 Jul 27, 2000
May 10, 2000 34234059H RESOLVE Non-Hazardous FAILURE TO COMPLY W/SITE SAFETY PLAN&PROGRAM:@TIME OF INSPECTION CONST.WORK WAS IN PROGRESS THERE WAS NO SITE SAFETY ... $1,000 $0 Jul 27, 2000
May 10, 2000 34234057Y RESOLVE Hazardous NO SITE SAFETY MANAGER:UPON INSPECTION@ABOVE PREMISES.THERE WAS NO SITE SAFETY MANAGER@SITE.REMEDY:PROVIDE SITE SAFET... $2,000 $0 Jul 27, 2000
Aug 13, 1999 34211504P RESOLVE Hazardous NO 18 GAGE STEEL WIRE AROUND THE SCAFFOLD AT FLOOR NO 5,4,3X2 AND FACADE OF THESE FLOORS WAS COMPLETLY REMOVED. WORKM... $750 $0 Jun 8, 2000
Aug 13, 1999 34211503N RESOLVE Hazardous MECHANCIAL DEMOLITION WITHOUT PERMIT AT TIME OF INSPECTION DEMOLITION BEING DONE BY MEANS OF MECHANCIAL WITH A BOBCAT... $800 $0 Jun 8, 2000
Aug 12, 1999 34211501J RESOLVE Hazardous FAILURE TO CARRY OUT DEMOLATION OPERATION IN A SAFE AND PROPER MANNER IN THAT THE BUILDING WAS NOT TAKEN DOWN IN A SY... $2,000 $0 Jun 8, 2000
Jul 30, 1999 34211842H RESOLVE Hazardous FAILURE TO GIVE 24 HRS NOTICES PRIOR TO COMMUNCEMENT OF DEMO REMEDY PROVIDE 24 HRS NOTICE TO THIS DEPT PRIOR TO COMMS... $2,500 $0 Dec 30, 1999
Jul 30, 1999 34211841X RESOLVE Hazardous FAILURE TO REMOVECX GLASS PRIOR THE COMMENCEMNET OF DEMOLITION REMEDY REMOVED ALL GLASS PRIOR THE START OF DEMOLITION... $2,500 $0 Dec 30, 1999
Jul 30, 1999 34211845N RESOLVE Hazardous WORK WITHOUT A PERMIT UPON INSPECTION AT ABOVE PREMISES DEMOLITION WORK WAS IN PRIGRESS WITHOUT OBTAINING A PERMIT DE... $2,500 $0 Dec 30, 1999
Jul 30, 1999 34211843J RESOLVE Hazardous FAILURE TO PROVIDE 24 HOURS NOTICE PRIOR TO START OF DEMOLITION AT TIME OF INSPECTION DEMOLITION WORK WAS IN PROGRESS... $2,500 $0 Dec 30, 1999
Jul 30, 1999 34211844L RESOLVE Hazardous FAILURE TO REMOVE GLASS PROIR TO TH ECOMMUNCEMENT DEMO UPON INSPECTION DEMO WAS IN PROGRESS AND GLASS WAS NOT REMOVED... $2,500 $0 Dec 30, 1999
Nov 10, 1997 34166786M RESOLVE Hazardous FAILURE TO MAINTAIN EXTERIOR BLDG WALL. NOTED: PARAPET WALL AT FRONT FACADE OF BLDG IS LEANING INWARD OUT OF PLUMB AP... $2,000 $0 Jan 15, 1998
Jul 2, 1997 34154578J RESOLVE Hazardous FAILURE TO MAINTAIN EXTERIOR BUILDING WALL. IN THAT PARAPET WALL AT ROOF IS LEANING AND OUT OF PLUMB AND CRACKED. REM... $2,000 $0 Aug 21, 1997
Jun 5, 1996 34137772Z RESOLVE Hazardous FAILURE TO MAINTAIN EXTERIOR BLDG WALL.HAZ.PARAPET WALL AT ROOF AT FRONT OF BLDG IS LEANING INWARD OUT OF PLUMB.BRICK... $800 $0 Sep 19, 1996
May 19, 1992 34073007L RESOLVE Hazardous FAILURE TO FILE A REPORT OF COMPLIANCE WITH LOCAL LAW 16/84-CERTIFYING TO THE INSTALLATION OF REQUIRED FIER PROTECTIO... $0 $0 Jul 2, 1992
May 19, 1992 34073012X RESOLVE Non-Hazardous FAILURE TO PROVIDE ELEVATOR LANDING SIGNS. FAILURE TO PROVIDE FLOOR NUMBERING SIGNS. FAILURE TO PROVIDE STAIR IDENTIF... $0 $0 Jul 2, 1992