ECB violations
517-519 West 45 Street, Manhattan • Block 01074 • Lot 0018
200 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Feb 24, 2022 | 35644894J | RESOLVE | CLASS - 1 | UNLAWFUL ACTS FAILURE TO COMPLY WITH COMMISSIONERS ORDERS.RECORDS INDICATE NO APP WAS MADE TO CORRECT OR CERTIFY ECB#... | $0 | $0 | Oct 20, 2022 |
| Jan 6, 2022 | 35644617L | RESOLVE | CLASS - 1 | UNLAWFUL ACTS FAILURE TO COMPLY W/COMMISSIONER'S ORDERS.RECORDS INDICATE NO APP WAS MADE TO CORRECT OR CERTIFY ECB #3... | $0 | $0 | Aug 11, 2022 |
| Nov 18, 2021 | 39051400M | RESOLVE | CLASS - 1 | FAILURE TO COM PLY WITH THE COMMISSIONER'S ORDER SUMMONS 35547817L STILL REMAINS, COMPLY WITH COMMISSIONER'S ORDER; C... | $0 | $0 | May 12, 2022 |
| Jun 2, 2021 | 35494224J | RESOLVE | CLASS - 1 | AN UNLAWFUL ACT FAILURE TO COMPLY WITH AN ORDER OF THE COMMISSIONER FAILURE TO CORRECT AND CERTIFY SUMMONS #35547817L... | $0 | $0 | Mar 28, 2022 |
| Apr 22, 2021 | 35547817L | RESOLVE | CLASS - 1 | UNAPPROVED/UNSAFE/UNSUITABLE ELECTRICAL EQUIPMENT,MATERIALS,DEVICES,APPLIANCES OR WIRING IN USE.EXTENSION CORDS USED ... | $0 | $0 | Mar 17, 2022 |
| Feb 17, 2021 | 39036375Y | RESOLVE | CLASS - 2 | WORK WITHOUT A PERMIT. (3) 240 VOLT ELECTRIC SECTIONS OF BASEBOARD HEATING INSTALLED WITH ASSOCIATED CONDUIT AND WIRI... | $0 | $0 | Apr 8, 2021 |
| Mar 13, 2020 | 35518260K | RESOLVE | CLASS - 2 | FAILURE TO COMPLY W/THE COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATION #39012061P ISSUED ON 10/28/19 & TO FILE A... | $0 | $0 | May 21, 2020 |
| Jan 9, 2020 | 35515167M | RESOLVE | CLASS - 2 | FAILURE TO COMPLY W/ THE COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATION#39012061P ISSUED ON 10/28/19 AND TO FILE... | $0 | $0 | Mar 19, 2020 |
| Oct 29, 2019 | 39011911H | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN; I OBSERVED FOUND SEVERAL YELLOW CAPS ON SPRINKLER SYSTEM WHICH WOULD NOT ALLOW WATER TO SPREAD A... | $625 | $0 | Dec 3, 2020 |
| Oct 28, 2019 | 39012061P | RESOLVE | CLASS - 1 | FILED A CERTIFICATE, FORM, APPLICATION ETC., CONTAINING A MATERIAL FALSE STATEMENT(S). NOTED, AT THE TIME OF INSPECTI... | $0 | $0 | Jun 29, 2020 |
| Jan 16, 2019 | 35332890J | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. AT TIME OF INSPECTION OF APT#5C,I NOTICED CRACKS IN THE FLOOR OF T... | $0 | $0 | Aug 1, 2019 |
| Jan 16, 2019 | 35332893P | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. AT TIME OF INSPECTION,I NOTICED THE BATHROOM WAS RAISED UP W/AN EL... | $0 | $0 | Aug 1, 2019 |
| Jan 16, 2019 | 35382106M | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.AT TIME OF INSPECTION OF APARMENT 5C.I NOTICED CRACKS IN THE FL... | $625 | $0 | May 14, 2020 |
| Jan 16, 2019 | 35332892N | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. NO FIRE STOPPING PER BC 712.3;27-345. AT TIME OF INSPECTION IN APT... | $0 | $0 | Aug 1, 2019 |
| Jan 16, 2019 | 35332891L | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. AT TIME OF INSPECTION,I NOTICED THE WOOD BEAMS THAT ARE OVERHEAD A... | $0 | $0 | Aug 1, 2019 |
| Jan 16, 2019 | 35382105K | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER AT THE TIME OF INSPECTION.I NOTICED THE WOOD BEAMS THAT ARE OVE... | $625 | $0 | May 14, 2020 |
| Jan 5, 2019 | 39001070N | RESOLVE | CLASS - 1 | AT TIME OF MY INSPECTION I OBSERVED IN THE LOBBY THE GAS SERVICE PIPE REMOVED AND NOW THERE IS NO GAS SERVICE TO APT'... | $625 | $0 | Jul 18, 2019 |
| Jan 4, 2019 | 39001069X | RESOLVE | CLASS - 2 | AT TIME OF MY INSPECTION IN APT 3C I OBSERVED A CONDENSATION PIPE IMPROPERLY DRAINING. , PROPERLY TRAP OR VENT FIXTURES. | $625 | $0 | Jul 18, 2019 |
| Dec 19, 2018 | 35375475M | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN CODE-COMPLAINT MANNER. NOTED: AT LOBBY FRONT ENTRANCE HAS A PIPE EXPOSED CREATING A H... | $1,250 | $0 | Jul 18, 2019 |
| Dec 5, 2018 | 38266672H | RESOLVE | CLASS - 1 | C/U 01A10,67B10,39O02,34D06,53U07,81Y02,42D06,42B09. CEASE USE ITEM 01-EMERGENCY STOP SWITCH HAS BEEN BYPASS, THIS IS... | $1,250 | $0 | Mar 21, 2019 |
| Nov 6, 2018 | 35356021Y | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.NOTED:PREMISES 5-STORY FRAME SEMI-ATTACHED MASONRY FRAME DWELLI... | $625 | $0 | May 24, 2019 |
| Jun 12, 2018 | 35332819R | RESOLVE | CLASS - 2 | WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND/OR APPROVED AMENDMENT. NOTED: IN THE COURTYARD OBSERED D... | $0 | $0 | Aug 2, 2018 |
| Feb 6, 2018 | 32093150J | RESOLVE | CLASS - 1 | B151,50A,50B. 50A- OIL BURNER SMOKING ON START UP IN NEED OF REPAIR 50B-REMOVE MUSHROOM TYPE RAIN CAP FROM CHIMNEY | $1,000 | $0 | Aug 30, 2018 |
| Jan 25, 2018 | 32091249K | RESOLVE | CLASS - 1 | B101, 50A. 50A-NO WORK PERMIT FILED WITH DOB FOR THE NEW CHIMNEY. | $0 | $0 | Oct 25, 2018 |
| Jan 25, 2018 | 32091248Z | RESOLVE | CLASS - 2 | B254,15,32A,50A,50B,50C,50D,50E,38. 50A-COLL,15-34A, 38. PLACE CORRODED AND LEAKING; 50B-BOILER ROOM NOW A STORAGE RO... | $500 | $0 | Oct 25, 2018 |
| Jan 9, 2018 | 35250056Z | RESOLVE | CLASS - 2 | FAILURE TO SAFEGUARD ALL PERSONS: NOTED IN MID AREA COURT YARD OF 5 BLDGS,ALL SAME BLOCK & LOT. CONSTRUCTION MATERIAL... | $400 | $0 | Aug 16, 2018 |
| Nov 20, 2017 | 35255667K | RESOLVE | CLASS - 1 | UNAPPROVED,UNSAFE,UNSUITABLE ELECTRICAL EQUIPMENT,APPLIANCES,APPARATUSMATERIALS OR WIRING.WORK NOTED:AT STREET LEVEL ... | $800 | $0 | Jul 26, 2018 |
| Sep 15, 2017 | 35288252J | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING PERSEXTION REQUIREMENTS. AT THE TIME OF INSPECTION,I OBSERVED THE ENTIRE 3R... | $400 | $0 | Jun 14, 2018 |
| Sep 5, 2017 | 35288253L | RESOLVE | CLASS - 1 | SEC. 3306.9.3 FAILURE TO PROVIDE ADEQUATE DUST CONTROL TO WORKERS/TENANAT. AT THE TIME OF INSPECTION I OBSERVED WORKE... | $400 | $0 | Jun 14, 2018 |
| Aug 24, 2017 | 35256284H | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN ADEQUATE HOUSKEEPING PER SECTION REQUIREMENTS. NOTED: DUST IN STAIRWELLS AS A RESULT OF ONGOING C... | $0 | $0 | Oct 12, 2017 |
| Aug 24, 2017 | 35256285J | RESOLVE | CLASS - 1 | PERFORMED UNLICENCED ELECTRICAL WORK. NOTED: @ TIME OF INSP. OBSERVED 3 CONST. WORKRS PERFORMING ELECTRICAL WORK, INC... | $4,800 | $0 | Jan 18, 2018 |
| Aug 17, 2017 | 35251519K | RESOLVE | CLASS - 1 | WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND OR APPROVED AMENDMENTS.AT TIME OF INSPECTION PLUMBING BE... | $1,000 | $0 | Oct 5, 2017 |
| Jun 23, 2017 | 38255983L | RESOLVE | CLASS - 1 | 97X10:THE ONLY ELEVATOR IN BLDG-OUT OF SERVICE.UPON INSPECTION THE DEVICE IS FOUND TO BE OUT OF SERVICE CREATING A HA... | $1,000 | $0 | Feb 22, 2018 |
| Jun 20, 2017 | 35256203R | RESOLVE | CLASS - 1 | PERFORMED UNLICENSED ELECTRICAL WORK NOTED:CONTRACTOR INSTALLED BX CABLE,PIPING,PANEL,SWITCHES,OUTLETS,LIGHTING FIXTU... | $4,800 | $0 | Mar 15, 2018 |
| Jun 20, 2017 | 35256205K | RESOLVE | CLASS - 1 | BC28-104.8.4/FAILURE TO COMPLY WITH TPP.NOTED:UNDER APPLICATION #122204462,DURING CONSTRUCTION OPERATIONS CONTRACTOR ... | $1,600 | $0 | Mar 15, 2018 |
| Jun 20, 2017 | 35256204Z | RESOLVE | CLASS - 1 | PERFORMING UNLICENSED PLUMBING WORK WITHOUT A MASTER PLUMBER LICENSE.NOTED:INSTALLED,CAST IRON WASTELINES,COPPER WATE... | $2,500 | $0 | Mar 15, 2018 |
| Jun 19, 2017 | 35244670H | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. AT TIME OF INSPECTION IT WAS OBSERVED THAT THERE WAS A HOLE IN... | $250 | $0 | Nov 2, 2017 |
| Jun 1, 2017 | 38254538Z | RESOLVE | CLASS - 1 | 59H11,2B10,49A07. 59H11-MACHINE BRAKE WITH COLLAPSED BEARINGS ON BREAKPULLEY CAUSING BREAK DRUM TO RUB AGAINST MACHIN... | $1,000 | $0 | Nov 16, 2017 |
| May 20, 2017 | 35244555M | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS. NOTED: AN INTERIOR DEMOLITION OF THE... | $1,600 | $0 | Apr 12, 2018 |
| Apr 25, 2017 | 35255329H | RESOLVE | CLASS - 1 | FILED A CERTIFICATE,FORM,APPLICATION ETC.CONTAINING A MATERIAL FALSE STATEMENT(S).ON 04/25/17,JOB#123090314-ALTERATIO... | $4,800 | $0 | Nov 16, 2017 |
| Nov 28, 2016 | 38251505Z | RESOLVE | CLASS - 2 | 97J5. UPDATE PERMIT TO CONTINUE WORK OR WITHDRAWAL THE APPLICATION. | $2,500 | $0 | Jan 12, 2017 |
| Nov 28, 2016 | 38251506K | RESOLVE | CLASS - 2 | 97J5. UPDATE PERMIT TO CONTINUE WORK OR WITHDRAWAL THE APPLICATION. | $2,500 | $0 | Jan 12, 2017 |
| Nov 28, 2016 | 38251504R | RESOLVE | CLASS - 1 | 40B16.PROVIDE SAFE ACCESS TO THE MOTOR ROOM THERE IS A HIGH VOLTAGE TRANSFORMER INSTALL 6 INCHES AWAY FROM THE BASE O... | $1,000 | $0 | Mar 16, 2017 |
| Oct 18, 2016 | 38250281Y | RESOLVE | CLASS - 1 | 02B10 NO OUTSIDE COMMUNICATION NEED TO BE REPAIRED. | $1,000 | $0 | Dec 8, 2016 |
| Oct 13, 2016 | 38250480R | RESOLVE | CLASS - 1 | 52BB12,2B10,41P7. FAILURE TO MAINTAIN IN CODE COMPLIANT MANNER AS PER BC 3001.2 AND 27-987 (52BB12) RESHACKLE CAR POU... | $1,000 | $0 | Dec 1, 2016 |
| Jan 6, 2016 | 35136322N | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER.NOTED:1)OBSERVED @ TIME OF INSP THE EMERGENCY LIGHTS ON PUBLIC HALL... | $1,000 | $0 | Apr 28, 2016 |
| Jan 6, 2016 | 35136321L | RESOLVE | CLASS - 1 | WORK W/O PERMIT.NOTED:@ PUBLIC HALLWAY OF THE 1ST FL 3RD FL RAMP 4TH.OBSERVED SEVERAL SPRINKLER HEADS REPLACE W/ NEW ... | $0 | $0 | Apr 28, 2016 |
| Dec 16, 2015 | 38239925N | RESOLVE | CLASS - 2 | 02-L-10:OUTSIDE COMMUNICATION NOT WORKING REPAIR. | $0 | $0 | Feb 4, 2016 |
| Oct 15, 2015 | 35146722L | RESOLVE | CLASS - 3 | WORK W/O A PERMIT. WORK NOTED: 1ST FL AUTO REPAIR AT FRONT ERECTED 2 WOODEN STRUCTURES: WEST SIDE PLYWOOD STRUCTURE A... | $200 | $0 | Jan 21, 2016 |
| Jan 28, 2015 | 38234658P | RESOLVE | CLASS - 2 | 05M07,06A11,05M07,CAR GATES MISSING PROVIDE.06M11,CAR GATE CONTACT ALTERED REMOVE JUMPER ON CONTROLLER. | $500 | $0 | Mar 19, 2015 |