ECB violations
600-602 West 48 Street, Manhattan • Block 01095 • Lot 0035
90 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Nov 25, 2008 | 34753704X | RESOLVE | CLASS - 1 | AS OF 11/3/08 UNLAWFULLY CONTINUED WORK WHILE ON NOTICE OF A STOP WORKORDER SUPPORTED SCAFFOLD REMOVED ON WEST ELEVAT... | $4,800 | $0 | Jan 15, 2009 |
| Nov 25, 2008 | 34753705H | RESOLVE | CLASS - 2 | AS OF 11/3/08 FAILURE TO POST D.O.T. PERMIT FOR STREET/SIDEWALK CLOSING. SIGN ON ONLY 1 ELEVATION OF SHED. REMEDY: CO... | $0 | $0 | Feb 19, 2010 |
| Nov 3, 2008 | 34720751H | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD ALL PERSONS AND PROPERTY AFFECTED BY CONSTRUCTIONOPERATIONS PLANKS COUNTER BALANCED BY ROPE AND ... | $2,400 | $0 | Jan 29, 2009 |
| Nov 3, 2008 | 34720752J | RESOLVE | CLASS - 1 | NO RECORD OF DAILY INSPECTION OF SUPPORTED SCAFFOLD PERFORMED BY AUTHORIZED PERSON AT SITE REM: COMPLY W/ CODE | $1,600 | $0 | Jan 22, 2010 |
| Nov 3, 2008 | 34720750X | RESOLVE | CLASS - 1 | SEC BC3314.5.56 27-1009 PLANKS NOT TIED DOWN AT WEST LOCATION AT ROOF LEVEL REM: COMPLY W/ CODE | $1,600 | $0 | Jan 29, 2009 |
| Sep 24, 2008 | 34706103Z | RESOLVE | CLASS - 1 | SEC. BC 3314.4.3 & 27-1045(B). NO RECORD OF DAILY INSPECTION OF SUPPORTED PIPE SCAFFOLD PERFORMED BY COMPETENT PERSON... | $1,600 | $0 | Nov 13, 2009 |
| Sep 16, 2008 | 38190542L | RESOLVE | CLASS - 2 | 100##.OBSERVED WORKER SMOKING WITHIN CONSTRUCTION SITE IN VIOLATION NYC FIRE CODE 140401 SMOKING OBSERVED ELEVATOR SH... | $1,200 | $0 | Nov 14, 2008 |
| Sep 16, 2008 | 34690388H | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING PER SECTION REQUIREMENTS NOTED AT TIME OF INSPECTION ON ACTIVE JOB EXCESSIV... | $800 | $0 | Nov 14, 2008 |
| Sep 16, 2008 | 34690389J | RESOLVE | CLASS - 1 | SEC.3308.3 VERTICAL SAFETY NETTING DAMAGED AND OR BROKEN AS NOTED AT TIME OF INSPECTION AT ACTIVE CONSTRUCTION SITE B... | $1,600 | $0 | Nov 14, 2008 |
| Sep 8, 2008 | 38190513M | RESOLVE | CLASS - 2 | 97M07 97M07 FAILURE TO NOTIFY DOB PRIOR TO DISMANTING & REMOVAL OF WORKERS HOIST EA #325107 | $0 | $0 | Aug 5, 2010 |
| Sep 8, 2008 | 38190512K | RESOLVE | CLASS - 1 | 05 05D NORTH GATE CAN BE OPENED AFTER LEAVING LOADING DOCK 16M FL GATES REMOVED WITHOUT INSTALLER CONSENT LEFT UNPROT... | $1,000 | $0 | Jul 17, 2009 |
| Sep 4, 2008 | 34689645L | RESOLVE | CLASS - 1 | SEC. BC3314.4.3. NO RECORD OF DAILY INSPECTION OF SUPPORTED SCAFFOLD PERFORMED BY COMPETENT PERSON AT SITE. AT THE TI... | $0 | $0 | Jun 17, 2010 |
| Jul 30, 2008 | 34689628J | RESOLVE | CLASS - 2 | WORK W/O PERMIT: EXPIRED PERMIT. SPRINKLER PERMIT EXPIRED. AT THE TIMEOF INSPECTION, 17 STORY ALTERATION JOB SITE IS ... | $400 | $0 | Jan 29, 2009 |
| Jul 30, 2008 | 34689629L | RESOLVE | CLASS - 2 | WORK W/O PERMIT: EXPIRED PERMIT. STANDPIPE PERMIT EXPIRED. AT THE TIME OF INSPECTION ON A 17 STORY CONSTRUCTION SITE,... | $400 | $0 | Jan 29, 2009 |
| Jul 30, 2008 | 34690983M | RESOLVE | CLASS - 2 | WORK W/O PERMIT EXPIRED PERMIT SPRINKLER PERMIT EXPIRED AT THE TIME OF INSPECTION 17STY ALTERATION JOBSITE IS IN PROG... | $0 | $0 | Jan 29, 2009 |
| Jul 22, 2008 | 38188961N | RESOLVE | CLASS - 1 | 06L10.16M7.70O2. 06 GATE SW. NOT WORKING FRONT GATE USE ITEM IS REPAIRED CALL 212-566-5542 16 INSTALL PLATES BY CENTE... | $5,000 | $0 | Apr 23, 2009 |
| Jul 15, 2008 | 34690431Y | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING. PER SECTION REQUIREMENTS. NOTED: AT TIME OF INSPECTION ON ACTIVE JOB SITE ... | $800 | $0 | Sep 4, 2008 |
| Jul 15, 2008 | 34690430M | RESOLVE | CLASS - 1 | FAILURE TO INSTITUTE/MAINTAIN SAFETY EQUIPMENT MEASURES OR TEMPORARY CONSTRUCTION - NO HANDRAILS. NOTED AT TIME OF IN... | $1,000 | $0 | Dec 4, 2008 |
| Jun 18, 2008 | 34655686M | RESOLVE | Hazardous | SCAFFOLD DOES NOT MEET BLDG CODE STANDARDS. AS NOTED: AT TIME OF INSPECTION IN ACTIVE CONSTRUCTION SITE PIPE SCAFFOLD... | $800 | $0 | Jun 25, 2009 |
| Jun 11, 2008 | 34655666P | RESOLVE | Hazardous | FAILURE TO SAFEGUARD PUBLIC & PROPERTY UPON INSPECTION AS NOTED GLASS PANELS APPROX. 8'X6' STORED LEANING AGAINST WAL... | $1,500 | $0 | Mar 19, 2009 |
| May 28, 2008 | 34643935X | RESOLVE | Hazardous | SAFETY NETTING DAMAGED - UPON INSPECTION AS NOTED VERTICAL SAFETY NETTING DAMAGED, TORN AND IN BAD SHAPE AT MANY PLAC... | $1,250 | $0 | Jul 24, 2008 |
| May 28, 2008 | 34643933M | RESOLVE | Hazardous | WORK W/O PERMIT - UPON INSPECTION AS NOTED PIPE SCAFFOLDING ERECTED AROUND ALL FOUR PERIMETER OF THE BLDG. THE PIPE S... | $800 | $0 | Jul 24, 2008 |
| Apr 15, 2008 | 38182992Z | RESOLVE | Hazardous | CEASE USE.05D06,84L10.05D-REAR GATE(AFTER LEAVING LOADING DOCK)W/O RESTRAINING.84L-OPERATING CONTROL.CEASE USE UNTIL ... | $800 | $0 | Jun 5, 2008 |
| Apr 15, 2008 | 34633443K | RESOLVE | Non-Hazardous | FAILURE TO SAFEGUARD PUBLIC AND PROPERTY-UPON INSPECTION ALTERATION WORK IS IM PROGRESS.AT TIME OF INSPECTION AS NOTE... | $1,500 | $0 | Aug 14, 2008 |
| Apr 15, 2008 | 34636034N | RESOLVE | Hazardous | "STOP ALL WORK".USING HOISTING EQUIPMENT IN AN UNSAFE MANNER.MATERIAL HOIST LOCATED @ 17FL EAST SIDE OF BLDG HAS THE ... | $4,000 | $0 | Aug 14, 2008 |
| Mar 4, 2008 | 34632559H | RESOLVE | Hazardous | FAILURE TO PROVIDE AT LEAST 2 MEANS OF EGRESS. AS NOTED: AT TIME OF INSPECTION ON ACTIVE CONSTRUCTION SITE, THERE IS ... | $0 | $0 | Apr 24, 2008 |
| Mar 4, 2008 | 34632556M | RESOLVE | Hazardous | SAFETY NETTING DAMAGED AND OR/BROKEN. AS NOTED: AT TIME OF INSPECTION ON ACTIVE CONSTRUCTION SITE, VERTICAL PERIMETER... | $1,250 | $0 | Apr 24, 2008 |
| Mar 4, 2008 | 34632558X | RESOLVE | Hazardous | SEC. 27-1014(B) STANDPIPE SYSTEM IN BLDG UNDER CONSTRUCTION NOT MAINTAINED IN ACCORDANCE W/27-1014. AS NOTED: AT TIME... | $880 | $0 | Apr 24, 2008 |
| Mar 4, 2008 | 34632557Y | RESOLVE | Hazardous | FAILURE TO PERFORM ADEQUATE HOUSEKEEPING. AS NOTED: AT TIME OF INSPECTION ON ACTIVE CONSTRUCTION SITE, EXCESSIVE AMOU... | $800 | -$79 | Apr 24, 2008 |
| Jan 23, 2008 | 34632521M | RESOLVE | Hazardous | FAILURE TO PROVIDE ESCAPE HATCHES AS REQUIRED AS NOTED:AT TIME OF INSPECTION ON ACTIVE CONSTRUCTION SITE CONCRETE WOR... | $500 | $0 | Mar 13, 2008 |
| Jan 23, 2008 | 34632522Y | RESOLVE | Hazardous | SEC-1069 THE STORAGE & USE OF ALL FLAMABLE VOLITALL COMBUSTIBLE COMPRESSED GAS AS NOTED:AT TIME OF INSPECTION ON ACTI... | $800 | $0 | Mar 13, 2008 |
| Dec 26, 2007 | 34627295R | RESOLVE | Hazardous | SEC:27-1009(A):FAILURE TO PROVIDE GUARDRAILS.AS NOTED:NO GUARDRAILS PROVIDED ON OPENING AREA ON 6TH,7TH,12TH,13TH & 1... | $800 | $0 | Feb 14, 2008 |
| Dec 26, 2007 | 34627296Z | RESOLVE | Hazardous | SEC. 27-1069. THE STORAGE & USE OF ALL FLAMMABLE VOLATILE COMBUSTIBLE AS NOTED: STORAGE & USE OF OXYGEN & ACETYLENE A... | $800 | $0 | Feb 14, 2008 |
| Nov 26, 2007 | 34615207J | RESOLVE | Hazardous | NO CONTRACTOR SIGN. NOTED: ALT IN PROGRESS UP TO 17TH FLR CONTRACTOR SIGN ON SIDEWALK BRIDGE STATED FLINTLOCK CONSTRU... | $0 | $0 | Apr 4, 2008 |
| Sep 25, 2007 | 34613654M | RESOLVE | Hazardous | NO FDNY PERMIT FOR STORAGE & USE OF COMBUSTIBLE MATERIAL. @ TIME OF INSPECTION A PAIR OF CYLINDERS (OXYGEN&ACETYLINE)... | $2,500 | $0 | Nov 15, 2007 |
| Sep 4, 2007 | 34582465Y | RESOLVE | Non-Hazardous | FAILURE TO COMPLY W/ SITE SAFETY PROGRAM AS PER REGULATION. DURING INSPECTION NO TOE BOARDS OR OVERHEAD PROTECTION IN... | $1,000 | $0 | Oct 25, 2007 |
| Sep 4, 2007 | 34582466X | RESOLVE | Non-Hazardous | SHED DOES NOT MEET BLDG CODE SPECIFICATION. DURING INSPECTION SIDE TOWARD BLDG WAS NOT SEALED B/W BOTTOM OF SHED & TO... | $2,000 | $0 | Oct 25, 2007 |
| Feb 23, 2007 | 34558121K | RESOLVE | Hazardous | FAILURE TO CARRY OUT DEMOLITION OPERATIONS IN SAFE & PROPER MANNER.NOTED:@ ROOF LEVEL WEST BULKHEAD(WATER TANK ENCLOS... | $2,000 | $0 | Apr 19, 2007 |
| Jul 25, 1989 | 34028205J | RESOLVE | Non-Hazardous | WORK WITHOUT A PERMIT WORK NOTED REMOVAL OF NORTH AND EAST BRICK PARAPET WALLS. REMEDY FILE PLANS OBTAIN PERMITS FOR ... | $125 | $0 | Sep 7, 1989 |
| Jul 18, 1989 | 34013713Y | RESOLVE | Hazardous | FAILURE TO MAINTAIN EXTERIOR BUILDING WALL HAZARDOUS DEFECT IS PARAPET WALL AT NORTH SIDE OF BUILDING APPROX 50 FT IN... | $625 | $0 | Aug 31, 1989 |