| Apr 8, 2026 | 35729851M | ACTIVE | CLASS - 1 | OCCUPANCY CONTRARY TO THAT ALLOWED BY THE CERTIFICATE OF OCCUPANCY OR BUILDING DEPARTMENT RECORDS.NOTE:AT TIME OF INS... | $6,250 | $0 | Jul 16, 2026 |
| Apr 3, 2025 | 35716847R | RESOLVE | CLASS - 1 | OCCUPANCY CONTRARY TO THAT ALLOWED BY THE CERTIFICATE OF OCCUPANCY OR BUILDINGS DEPARTMENT RECORDS. AS NOTED AT TIME ... | $2,500 | $0 | Jul 10, 2025 |
| Mar 25, 2025 | 39142803K | RESOLVE | CLASS - 2 | OBSERVED NUMEROUS UNLINKED PLASTIC BARRIERS MISSING REFLECTORS AND MISSING CAPS, COMPLY WITH SPECIFICATIONS | $1,250 | $0 | May 29, 2025 |
| Feb 13, 2023 | 35646932K | RESOLVE | CLASS - 2 | WORK WITHOUT A PERMIT.OBSERVED ELECTRICAL WORK ON 2ND FLOOR LEVEL NEXTTO GYM NEW BOX CABLE,NEW ELECTRICAL PANEL BOX,N... | $0 | $0 | Apr 20, 2023 |
| Sep 9, 2021 | 35506138Z | RESOLVE | CLASS - 1 | WORK W/O PERMIT. NOTE: AT TIME OF COMP INSPECTION AT OCCUPIED 47 STY MIXED USE BLDG I OBSERVED STOREFRONT PARTIALLY D... | $1,250 | $0 | Sep 15, 2022 |
| Jun 11, 2019 | 35402232Z | ACTIVE | CLASS - 2 | VIOLATION OF DISCRETIONARY ZONING CONDITIONS ON PRIVATELY OWNED PUBLICSPACE. AT TIME OF INSPECTION. NOTED: FOLLOWING ... | $5,000 | $0 | Dec 5, 2019 |
| Apr 8, 2019 | 38269400H | RESOLVE | CLASS - 1 | CEASE USE. 5A10, 70N10, 59B07, 68B07, 70Q03, 100D06, 21Q03, 26D06. (05)DOOR ZONE RESTRICTOR HAS BEEN ALTERED AND REND... | $3,125 | $0 | Aug 29, 2019 |
| Feb 7, 2017 | 38252815Z | RESOLVE | CLASS - 1 | 52M11,52K11,68M7. HOIST ROPES ARE RUSTED AND UNDERSIZED REPLACE; ONE HOIST ROPE CUT OUT REPLACE; NO SERVICE COMPANY L... | $1,000 | $0 | Jul 6, 2017 |
| Feb 7, 2017 | 38252814R | RESOLVE | CLASS - 2 | 5X10,59U15,52H11,68M7. REPAIR CAR ZONE LOCK, TAG MACHINE BRAKE.HOIST ROPE ROUGED-REPLACE PROVIDE MAINTENANCE LOG. | $500 | $0 | Mar 30, 2017 |
| Nov 29, 2016 | 38250209J | RESOLVE | CLASS - 2 | 52K11 REPALCE RUSTED HOIST CABLES | $500 | $0 | Mar 30, 2017 |
| Nov 29, 2016 | 38250210R | RESOLVE | CLASS - 2 | 52K11 REPLACE RUSTED HOIST CABLES. | $500 | $0 | Mar 30, 2017 |
| Sep 20, 2016 | 35199614N | RESOLVE | CLASS - 1 | PARTIAL SWO ISSUED FOR SUSPENDED SCAFFOLDS PURSUANT 28-207.2 AND POSTED ON PREMISES. FAILURE TO PROVIDE GUARDRAILS. N... | $1,200 | $0 | Nov 10, 2016 |
| Oct 9, 2015 | 35157385N | RESOLVE | CLASS - 2 | SEC. 3310.8.4 FAILURE TO MAINTAIN A SITE SAFETY LOG. NOTED: AT TIME OFMY INSPECTION A SUSPENDED SCAFFOLD WAS INSTALLE... | $0 | $0 | Dec 3, 2015 |
| Oct 9, 2015 | 35157384L | RESOLVE | CLASS - 2 | FAILURE TO NOTIFY THE DEPT PRIOR TO(UNCIAL)INSTALLATION OF (OUTRIGGER BEAM)ADJUSTABLE SUSPENDED SCAFFOLD. NOTED: AT T... | $400 | $0 | Dec 3, 2015 |
| Aug 12, 2014 | 35098682M | RESOLVE | CLASS - 1 | 3310.8.3,FAILURE TO COMPLY W/ RULES PROMULGATED BY THE COMM'S:SITE SAFETY LOG BOOK.@ TIME OF INSP OBSERVED ACTIVE FAC... | $1,600 | $0 | Oct 2, 2014 |
| Aug 12, 2014 | 35098683Y | RESOLVE | CLASS - 1 | 3310.6,DESIGNATED SITE SAFETY MANAGER.@ TIME OF INSP OBSERVED ACTIVE FACADE WORK ONGOING.INSP OF LOGBOOK SHOWS NO REC... | $1,600 | $0 | Oct 2, 2014 |
| Jul 9, 2014 | 35099319M | RESOLVE | CLASS - 2 | FAILED TO NOTIFY DEPT PRIOR TO USE/INST OFF C-HOOKS IN CONNECTION W/ SUSPENDED SCAFFOLD.NOTED:@ TIME OF INSP C-HOOKS ... | $400 | $0 | Aug 28, 2014 |
| Jul 17, 2013 | 34983922H | ACTIVE | CLASS - 3 | WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND/OR APPROVED AMENDMENTS JOB #121122891 DATED DECEMBER 21,... | $200 | $0 | Oct 10, 2013 |
| Oct 23, 2012 | 34842392K | RESOLVE | CLASS - 2 | WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENT AND/OR APPROVED AMENDMENTS JOB #121122891. NOTED: 1) THE 2 NE... | $250 | $0 | Dec 13, 2012 |
| Nov 4, 2011 | 34934054X | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. NOTED: AT GARAGE, THE EMERGENCY FIRE EXIT STAIRWELL, FROM SUB ... | $1,000 | $0 | Apr 19, 2012 |
| Nov 22, 2010 | 38214202Z | RESOLVE | CLASS - 2 | 05X10,17D06,61G11. 05X- DOOR ZONE RESTRICTOR. 17D- LOBBY. 61G- UNREADABLE FUSES | $500 | $0 | Jan 13, 2011 |
| Mar 24, 2009 | 32066395Y | RESOLVE | CLASS - 3 | 18B.48B.50A.24B 50A INSTALL FLUE PIPE SUPPORT W/ THREADED ROD AND CHANNEL FOR PROPER SUPPORT | $0 | $0 | May 14, 2009 |
| Mar 24, 2009 | 32066394M | RESOLVE | CLASS - 3 | 18B.50A.50B.50A. SAFETY VLALVE INLET HAS EVIDENCE OF A LEAK 50B WATER COLUMN NIPPLE LEAKING | $0 | $0 | May 14, 2009 |
| Jan 31, 2008 | 34628950Z | RESOLVE | Non-Hazardous | FAILURE TO PROVIDE THE NECESSARILY BICYCLE PARKING IN THE(PLENARY)SPACE AS INDICATED ON A SITE PLAN BY PHILLIP.(BIRNB... | $480 | $0 | May 22, 2008 |
| Jan 31, 2008 | 34628951K | RESOLVE | Non-Hazardous | 27-42 FAILURE TO PROVIDE THE REQUIRED PLAQUE IN THE PRIMARY SPACE IN THE PUBLIC PLAZA AREA. REMEDY: PROVIDE THE NECES... | $480 | -$960 | May 22, 2008 |
| Jan 28, 2008 | 38181147R | RESOLVE | Non-Hazardous | 83R.83R WORKING W/O PERMIT | $850 | $0 | Mar 20, 2008 |
| Aug 28, 2007 | 32052304M | RESOLVE | Non-Hazardous | 18B. | $180 | $0 | Jan 31, 2008 |
| Jun 9, 2006 | 32051760L | RESOLVE | Non-Hazardous | 48A,18A,18B,50A,50B,50C.50A-INSTALL STRUCTUAL SUPPORTS IN FLU PIPE. 50B-BOILER OPERATING OVER 100PSI & REQUIRES A BLO... | $0 | $0 | Jul 27, 2006 |
| Jun 9, 2006 | 32051759Y | RESOLVE | Non-Hazardous | 0A,50B,50C,48B.50-A REPOSTION BOILER TO GIVE CLEARANCE TO RIGHT OF BOILER TO SERVICE AND INSPECT HAND HOLE A MINIUMN ... | $0 | $0 | Jul 27, 2006 |
| Sep 13, 2004 | 32045422H | RESOLVE | Non-Hazardous | 34A/32A 2004 FULTON NATL BD #96031 32A LIGHT SWITCH BY DOOR IN BOILER ROOM IS MISSING THE SWITCH PLATE | $350 | $0 | Jan 13, 2005 |
| May 24, 2004 | 32044726M | RESOLVE | Non-Hazardous | 40 FULTON VERT TBLS BLR 10HP NB55380 GAS 1988 40-DRAFTSTAT ELEMENT THERMALLY DEFORMED AND INOPERABLE REPLACE | $0 | $0 | Jul 8, 2004 |
| May 24, 2004 | 32044725K | RESOLVE | Non-Hazardous | BQ9/36 FULTON VERT TBLS BOILER 15HP NB 96031 GAS 2004 THE REFERENCED BOILER WAS INSTALLED A REPLACEMENT UNIT WITHOUT ... | $500 | $0 | Jul 8, 2004 |
| Dec 17, 2002 | 38133985J | RESOLVE | Non-Hazardous | 31D07/01I12/39B01/30B07/27D06/28D06. 31 CLEAR SMOKE HOLES. 01 REPLACE DAMAGED STOP SWITHC. 37 ELIMANE MSC BOARD TRIPP... | $180 | $0 | Mar 20, 2003 |
| Dec 17, 2002 | 38133984H | RESOLVE | Non-Hazardous | 02B07/31D07/57I11/05B11/05B10/30B07. 02 PROVIDE ALARM ON CAR. 31 CLEAR SMOKE HOLES. 57 REPAIR DAMAGED HOIST MOTOR COM... | $180 | $0 | Mar 20, 2003 |
| Oct 6, 2000 | 38108328P | RESOLVE | Non-Hazardous | 46H12 46-H-12=REPLACE HOIST CABLES.UNDER SIZED+(ROUGE) | $2,500 | $0 | Nov 16, 2000 |
| Oct 6, 2000 | 38108329R | RESOLVE | Non-Hazardous | 46H12 46-H-12=REPLACE HOIST CABLES UNDER SIZED+(ROUGE) | $2,500 | $0 | Nov 16, 2000 |
| Dec 20, 1999 | 34223456H | ACTIVE | Non-Hazardous | FAILURE TO FILE A REPORT OF COMPLIANCE WITH LOCAL LAW 16/84- CERTIFYING TO THE INSTALLATION OF REQUIRED FIRE PROTECTI... | $200 | $0 | Mar 23, 2000 |
| Jan 15, 1999 | 34183157Y | RESOLVE | Hazardous | FAILURE TO MAINTAIN EXTERIOR BLDG WALL. IN THAT A HAZARDOUS CONDITIONEXIST AT 24TH FL. CONCRETE PATIO FL ON THE SOUTH... | $800 | $0 | Mar 4, 1999 |
| Oct 23, 1998 | 32016525H | RESOLVE | Non-Hazardous | 18A-HANDHOLES CORRODED. | $180 | $0 | Dec 18, 1998 |
| Oct 23, 1998 | 32016524X | RESOLVE | Non-Hazardous | 6A,51. 6A-SAFETY OR RELIEF VALVE DEFECTIVE. 51-HAZARDOUS CONDITION- BOILER SEALED. | $400 | $0 | Dec 18, 1998 |
| Jan 27, 1994 | 32010636N | RESOLVE | Non-Hazardous | 46A 46B | $125 | $0 | Apr 14, 1994 |
| Jan 27, 1994 | 32010637P | RESOLVE | Non-Hazardous | 46A 46B | $125 | $0 | Apr 14, 1994 |