ECB violations
Special Music School, Manhattan • Block 01139 • Lot 0008
18 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Feb 25, 2026 | 35728973X | ACTIVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.ILLUMINATION FOREXITS,EXIT DISCHARGES AND PUBLIC CORRIDORS PER ... | $1,250 | $0 | Mar 19, 2026 |
| Feb 25, 2026 | 35728972Y | ACTIVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: A(CELLAR) ELECTRIC METER RM C15 WITH STORAGE OF MULTIPL... | $1,250 | $0 | Mar 20, 2026 |
| Feb 25, 2026 | 35728974H | ACTIVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.LACK OF EMERGENCY LIGHTING FOR EXITS,EXIT DISCHARGES AND PUBLIC... | $1,250 | $0 | Mar 19, 2026 |
| Mar 5, 2021 | 35546438R | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER:USE OF PROHIBITED DO-OR AND/OR HARDWARE PER BC1008.1.8;27-371(J)NOT... | $625 | $0 | Jun 10, 2021 |
| Mar 21, 2017 | 38253238M | RESOLVE | CLASS - 1 | CU-05A17 CEASE USE. DOOR ZONE RESTRICTOR HAS BEEN DISABLED AND RENDERED INOPERATIE. THIS IS A SAFETY DEVICE TO ENSURE... | $1,000 | $0 | Jun 29, 2017 |
| Apr 8, 2015 | 35128136J | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER PROVIDE REQUIRED CORRDIOR WIDTH PER 1016.2;27-369.NOTE:ON THE 6TH F... | $0 | $0 | Jun 18, 2015 |
| May 31, 2013 | 35019020P | RESOLVE | CLASS - 2 | FLRS 6,3,2 - ELECTRIC CLOSETS FIRE STOPPING MISSING. REMEDY: PROVIDE &MAINTAIN FIRE STOPPING AS PER CODE. | $250 | $0 | Nov 21, 2013 |
| Mar 2, 2012 | 34941394H | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLAINT MANNER: NOTE AT CELLAR LEVEL OF ABOVE PREMISES ELECTRICAL MAIN ROOM IS... | $250 | $0 | Apr 19, 2012 |
| Apr 7, 2004 | 34432708X | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN BUILDING DEFECT(S) NOTED : MISSING DOOR CLOSERS - 2 DOORS BASEMENT @ BACK STAGE AREA ( LEFT SIDE ... | $0 | $0 | Jun 17, 2004 |
| Feb 4, 2003 | 38136079L | RESOLVE | Non-Hazardous | 03I4-45B01-39B01. 03-REPAIR COP DOOR 39-45 ELIMINATE EXCESSIVE DELAY IN START BOUNCING WHILE RUNNING. | $0 | $0 | Mar 27, 2003 |
| Feb 4, 2003 | 38136078J | RESOLVE | Non-Hazardous | 03B11-19B07-26B07-30F11-10M12-17M12. 03-REPAIR CAB TELEPHONE. 19-REPLACE MISSING DOOR LOCK COUERS 26-REPLACE DOOR OPE... | $0 | $0 | Mar 27, 2003 |
| Jan 28, 2003 | 38135649J | RESOLVE | Hazardous | 52#11-81B05. 52-REPAIR CRINDING OUERHEATING AND EXCESSIVE NOISE VIBRATION MAIN MACHINE GEARING BEFORE RETURNING TO SE... | $500 | $0 | Mar 20, 2003 |
| Aug 31, 2001 | 38118702P | RESOLVE | Non-Hazardous | 75B05-PERFORM 5 YEAR TAST PROPERLY TAG GOVERNOR. | $350 | $0 | Feb 28, 2002 |
| Jul 2, 1999 | 38087980X | RESOLVE | Non-Hazardous | 50Y,25M. MAIN MACHINE LEAKING OIL, PROVIDE DOOR OPERATOR COVER. | $350 | $0 | Aug 19, 1999 |
| Jan 7, 1999 | 34196609Z | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN. DEFECT IS EAST EXTERIOR FACADE UNPROTECTED. ALLOWING WATER TO PENETRATE INTO STAIRWELL. ALL FLOO... | $0 | $0 | Apr 22, 1999 |
| Jul 7, 1993 | 34087572L | RESOLVE | Non-Hazardous | FAILURE TO PROVIDE ADEQUATE EMERGENCY POWER EXIT LIGHT PURSUANT TO BEC STANDARDS FAILURE TO PROVIDE ADEQUATE EMERGENC... | $0 | $0 | Nov 18, 1993 |
| Mar 1, 1991 | 34049266X | RESOLVE | Hazardous | USE OF SUPERVISION SCAFFOLD WITHOUT A SPECIAL RIGGERS LICENSE REMEDY OBTAIN LICENSE USE OF SUSPENSION SCAFFOLD WITHOU... | $1,420 | $0 | Jul 12, 1991 |
| Feb 13, 1991 | 34054223M | RESOLVE | Non-Hazardous | FAILURE TO PROVIDE EMERGENCY POWER EXIT LIGHTS (IN HALLWAYS THROUGHOUT FLOORS). REMEDY: PROVIDE EMERG. PWR. EXIT LIGH... | $600 | $0 | Jun 27, 1991 |