ECB violations
161 West 75 Street • Block 01147 • Lot 7501
50 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Sep 26, 2023 | 39522082Y | RESOLVE | CLASS - 2 | AT THE TIME OF MY INSPECTION I OBSERVED SIDEWALK SHED INSTALLED AT EXPOSURE 1 AND 2 -AT EXPOSURE 2 HORIZONTAL BRACING... | $2,400 | $0 | Nov 30, 2023 |
| Sep 26, 2023 | 39522106J | RESOLVE | CLASS - 2 | AT THE TIME OF MY INSPECTION I OBSERVED SUPPORTED SCAFFOLD INSTALLED NEXT TO ADJ PROPERTY AND WORK ONGOING ON ROOF PA... | $0 | $0 | Nov 30, 2023 |
| Apr 30, 2020 | 39021778R | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. EXHAUST DISCHARGE MUST BE NO CLOSER THAN 10 FEET FROM THE BUIL... | $0 | $0 | Jul 23, 2020 |
| Apr 30, 2020 | 39021750P | RESOLVE | CLASS - 2 | FAILURE TO CONDUCT OR FILE A FINAL INSPECTION OF PERMITTED WORK WITH THE DEPARTMENT. AT TIME OF INSPECTION, OBSERVED ... | $3,125 | $0 | Jul 23, 2020 |
| Mar 11, 2015 | 35079349P | RESOLVE | CLASS - 1 | ELECTRICAL WORK W/O A PERMIT. THE ENTIRE APT 15E: BRANCH CIRCUIT WIRING,RECEPTACLES OUTLETS,SWITCHES,LIGHTING FIXTURE... | $800 | $0 | Sep 10, 2015 |
| Jan 13, 2015 | 35150336P | RESOLVE | CLASS - 2 | BC 3314.4.1.5 NOTIFICATION OF ADJUSTABLE SUSPENDED SCAFFOLD REMOVAL.PRIOR TO THE FINAL REMOVAL OF THE ADJUSTABLE SUSP... | $0 | $0 | Apr 9, 2015 |
| Jul 27, 2012 | 34842248X | RESOLVE | CLASS - 3 | FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER.SERVICE DOOR FROM APT IS BLOCKED W/ WALL(NO EXIT @ THAT LOCATION).R... | $100 | $0 | Sep 13, 2012 |
| Jun 21, 2012 | 34944549R | RESOLVE | CLASS - 1 | SEC. 1RCNY9-01 RIGGER FAILED TO NAME A DESIGNATED FOREMAN. CARLOS ROJAS IS SUSPENDED & WORKING ON (BOATSMAN) CHAIR NO... | $1,600 | $0 | Sep 27, 2012 |
| May 15, 2012 | 34944336N | RESOLVE | CLASS - 2 | SIDEWALK SHED DOES NOT MEET CODE SPECIFICATIONS. SHED DOES NOT EXTEND 20 FT AS REQUIRED SHED IS AT EXP #1. REM:CONFOR... | $2,400 | $0 | Jul 5, 2012 |
| Dec 9, 2009 | 34815354X | RESOLVE | CLASS - 1 | UNLAWFULLY CONTINUED WORK WHILE ON NOTICE OF A STOP WORK ORDER. NOTED STOP WORK ORDERS WERE ISSUED ON 4-16-08 AND 8-6... | $24,000 | $0 | May 6, 2010 |
| Dec 9, 2009 | 34815351K | RESOLVE | CLASS - 1 | INADEQUATE SAFETY MEASURES : OPERATION OF HOISTING EQUIPMENT IN AN UNSAFE MANNER. NOTED SCAFFOLD PLATFORM @ EXP. # 4 ... | $4,800 | $0 | May 6, 2010 |
| Dec 9, 2009 | 34815352M | RESOLVE | CLASS - 1 | FAILURE TO PERFORM A SAFE / PROPER INSPECTION OF SUSPENDED SCAFFOLD. NOTED SCAFFOLD @ EXP. # 4 @ 12TH FL. C-HOOKS @ R... | $10,000 | $0 | May 6, 2010 |
| Dec 9, 2009 | 34815353Y | RESOLVE | CLASS - 1 | NO RECORD OF DAILY INSPECTION OF SUSPENDED SCAFFOLD PERFORMED BY AN AUTHORIZED PERSON @ SITE. NOTED FULLY OPERATIONAL... | $2,400 | $0 | May 6, 2010 |
| Jul 6, 2009 | 38202337H | RESOLVE | CLASS - 1 | 01L10 01 REPAIR DEFECTIVE EMERGENCY STOP SWITCH CU UNTIL SWITCH IS REPAIRED CALL 212 566-5544 WHEN READY FOR SERVICE | $1,000 | $0 | Oct 7, 2010 |
| Jan 9, 2009 | 36008093Z | RESOLVE | CLASS - 2 | FAILURE TO FILE AN AMENDED FIFTH ROUND REPORT ACCEPTABLE TO THIS DEPT INDICATING CORRECTION OF UNSAFE CONDITIONS DESC... | $4,000 | $0 | May 28, 2009 |
| Dec 24, 2008 | 34753103K | RESOLVE | CLASS - 1 | UNLAWFULLY CONTINUED WORK WHILE ON NOTICE OF A STOP WORK ORDER. NOTED:ALL EQUIPMENT REMOVED. REMEDY: COMPLY W/CODE. | $4,800 | $0 | Jun 4, 2009 |
| Nov 12, 2008 | 38192972K | RESOLVE | CLASS - 2 | 53H11.70P16.56Y13.60Q03.71X10.77O02.52H11.37T07.10H11.32H10.29M11.39O02.52B11.05B11.21M11.16B11.53H11. GOVERNOR ROPE ... | $2,500 | $0 | Jun 25, 2009 |
| Nov 12, 2008 | 38192973M | RESOLVE | CLASS - 2 | 52H11.53H11.52B11.16M07.26D06.37T07.70B07.73O02.74O02.34O02.12Q03.21M07.32H10.52H11 REPLACE WORN HOIST ROPES 53H11 RE... | $500 | $0 | Jul 22, 2010 |
| Aug 6, 2008 | 34684817X | RESOLVE | CLASS - 2 | WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND/OR APPROVED AMENDMENTS.(INSUFFICIENT COUNTER WEIGHTS). R... | $250 | $0 | Oct 23, 2008 |
| Aug 6, 2008 | 34684816Y | RESOLVE | CLASS - 2 | WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND/OR APPROVED AMENDMENTS. (INSUFFICIENT COUNTER WEIGHTS). ... | $500 | $0 | Oct 23, 2008 |
| Apr 16, 2008 | 34636070K | ACTIVE | Hazardous | NO CERTIFICATE OF FITNESS FOR SCAFFOLD WORKERS ON SITE AT TIME OF INSPECTION. | $1,500 | $0 | Jun 12, 2008 |
| Apr 16, 2008 | 34636071M | ACTIVE | Hazardous | WORK DOEST CONFORM TO APPROVED DRAWINGS IN CO-5: 1) INSUFFICIENT COUNTER WEIGHT FOR OUTRIGGER BEAMS: INSTALLED 950LB ... | $500 | $0 | Jun 12, 2008 |
| Aug 16, 2007 | 34496010R | RESOLVE | Hazardous | INSTALLED EQUIPMENT DOES NOT MATCH APPROVED PLANS/DRAWINGS.WORK CONTRARY TO DEPT OF BLDG APPROVED PLANS & APPLICATION... | $500 | $0 | Nov 8, 2007 |
| Feb 17, 2006 | 34549532K | RESOLVE | Non-Hazardous | FAILURE TO FILE AN AMENDED SIXTH ROUND REPORT ACCEPTABLE TO THIS DEPT INDICATING CORRECTION OF UNSAFE CONDITIONS DESC... | $10,000 | $0 | Mar 1, 2007 |
| Feb 17, 2006 | 34549521P | RESOLVE | Non-Hazardous | FAILURE TO FILE AN AMENDED 5TH ROUND REPORT ACCEPTABLE TO THIS DEPT. INDICATING CORRECTION OF UNSAFE CONDTIONS DESCRI... | $10,000 | $0 | Apr 27, 2006 |
| Oct 21, 2005 | 34548633P | RESOLVE | Non-Hazardous | FAILURE TO FILE AN AMENDED SIXTH ROUND REPORT ACCEPTABLE TO THIS DEPARTMENT INDICATING CORRECTION OF UNSAFE CONDITION... | $2,500 | $0 | Mar 1, 2007 |
| Oct 21, 2005 | 34548620X | RESOLVE | Non-Hazardous | FAILURE TO FILE AN AMENDED SIXTH ROUND REPORT ACCEPTABLE TO THIS DEPARTMENT INDICATING CORRECTION OF UNSAFE CONDITION... | $700 | $0 | Feb 23, 2006 |
| Jul 15, 2005 | 34458939Z | RESOLVE | Non-Hazardous | FAILURE TO SUBMIT A FIFTH ROUND TECHNICAL REPORT IN COMPLIANCE WITH CODE PROVISIONS:PERIODIC INSPECTION OF EXTERIOR W... | $350 | $0 | Sep 1, 2005 |
| Apr 29, 2005 | 34458451P | RESOLVE | Non-Hazardous | FAILURE TO SUBMIT A FIFTH ROUND TECHNICAL REPORT IN COMPLIANCE WITH CODE PROVISIONS: PERIODIC INSPECTION OF EXTERIOR ... | $0 | $0 | Dec 29, 2005 |
| Feb 18, 2005 | 34461088R | RESOLVE | Non-Hazardous | FAILURE TO SUBMIT A FIFTH ROUND TECHNICAL REPORT IN COMPLIANCE WITH CODE PROVISIONS:PERIODIC INSPECTION OF EXTERIOR W... | $700 | $0 | May 31, 2007 |
| Nov 12, 2004 | 34462288X | RESOLVE | Non-Hazardous | FAILURE TO SUBMIT A FIFTH ROUND TECHNICAL REPORT:PERIODIC INSPECTION OF EXTERIOR WALLS AND APPRURTENANCES AS REQUIRED... | $0 | $0 | Dec 29, 2005 |
| Jun 11, 2004 | 34459404R | RESOLVE | Non-Hazardous | FAILURE TO SUMBIT A FIFTH ROUND TECHNICAL REPORT: PERIODIC INSPECTION OF EXTERIOR WALLS & APPURTENANCES AS REQUIRED B... | $0 | $0 | Jan 27, 2005 |
| Feb 27, 2004 | 34463113Z | RESOLVE | Non-Hazardous | FAILURE TO SUBMIT A FIFTH ROUND TECHNICAL REPORT: PERIODIC INSPECTION OF EXTERIOR WALLS AND APPURTENANCES AS REQUIRED... | $2,500 | $0 | Jul 15, 2004 |
| Feb 2, 2000 | 38094070M | RESOLVE | Non-Hazardous | 15I11,15O02,16L11,26Q07,27Q07,31Q07,40E11,50F11,73O02. 15- REPAIR DOOR GIBS WHERE NECESSARY. 15-CLEAN 16- REPAIR 26- ... | $0 | $0 | Mar 23, 2000 |
| Feb 2, 2000 | 38094067L | RESOLVE | Non-Hazardous | 01L11,02L11,15P,39H08,46L11,47O02,48J01,50F11,60J07. 01,02- AUDIBLE INCAR. 15- ACCESS SWITCH, BASEMENT DOOR. 39-REGRO... | $500 | -$500 | Mar 24, 2000 |
| Feb 2, 2000 | 38094072X | RESOLVE | Non-Hazardous | 15L11,30P07,48J15,73O02. REPAIR ACCESS KEY HOLE. 30-PROVIDE, 48- SHORTEN COUNTER WEIGHT CABLE PROVIDE PROPER CLEARANC... | $0 | $0 | Mar 23, 2000 |
| Feb 2, 2000 | 38094069P | RESOLVE | Non-Hazardous | 15H11,47O02,64J15. 15- REPAIR DOOR GIBS WHERE NECESSARY. 47- CLEAN 64-SHORTEN COMPENSATION. | $0 | $0 | Mar 23, 2000 |
| Feb 2, 2000 | 38094068N | RESOLVE | Non-Hazardous | 15L11,30P07,35Z14,48J15. 15-REPAIR ACCESS SWITCH ON HOISTWAY DOOR. 30- PROVIDE 35-SEAL WATER LEAK 48-SHORTEN COUNTER ... | $0 | $0 | Mar 23, 2000 |
| Feb 2, 2000 | 38094071Y | RESOLVE | Non-Hazardous | 30P07,16L11,73O02. 30- PROVIDE 16- REPAIR WHERE NECESSARY 73- CLEAN INSTALLATION. | $0 | $0 | Mar 23, 2000 |
| Sep 22, 1995 | 34130951M | RESOLVE | Non-Hazardous | FAILURE TO PROVIDE APPROVED PLANS AT PREMISES AT TIME OF INSPECTION. LOCATION: ENTIRE BLDG. WALL AND PARAPET. REMEDY:... | $0 | $0 | Nov 9, 1995 |
| Sep 15, 1995 | 38051622L | RESOLVE | Non-Hazardous | 05I, REPAIR OR RENEW GATE CEASE USE. UNTIL WORK IS DONE. | $100 | -$100 | Jun 6, 1996 |
| Jan 18, 1995 | 38046556X | RESOLVE | Non-Hazardous | 39M. | $0 | $0 | Mar 23, 1995 |
| Feb 17, 1993 | 38031513Y | RESOLVE | Non-Hazardous | 74# 22D 11Q 35#74 CITY DEVICE NUMBER IDENTIFICATION TAGS 35# COMPANYS NAME | $100 | $0 | May 20, 1993 |
| Feb 17, 1993 | 38031512M | RESOLVE | Non-Hazardous | 74# 35# 74 CITY DEVICE NUMBER IDENTIFICATION TAGS 35# COMPANYS NAME | $100 | $0 | May 20, 1993 |
| Feb 17, 1993 | 38031516J | RESOLVE | Non-Hazardous | 74# CITY DEVICE NUMBER IDENTIFICATION TAGS | $100 | $0 | May 20, 1993 |
| Feb 17, 1993 | 38031515H | RESOLVE | Non-Hazardous | 22D 11Q 05I 35# 74# 35# 35 BROKEN WATER PIPE IN MOTOR ROOM 74# CITY DEVICE NUMBER IDENTIFICATION TAGS 35 COMPNAYS NAME | $100 | $0 | May 20, 1993 |
| Feb 17, 1993 | 38031517L | RESOLVE | Non-Hazardous | 74# 35# 74 CITY DEVICE NUMBER IDENTIFICATION TAGS 35 COMPANYS NAME | $100 | $0 | May 20, 1993 |
| Feb 17, 1993 | 38031514X | RESOLVE | Non-Hazardous | 74# 35# 74 CITY DEVICE NUMBER IDENTIFICATION TAGS 35 COMPANYS NAME | $100 | $0 | May 20, 1993 |
| Jan 31, 1991 | 38004883H | RESOLVE | Non-Hazardous | 39H 74A PROVIDE CAPACITY PLATE | $1,000 | $0 | May 30, 1991 |
| Jan 31, 1991 | 38004884J | RESOLVE | Non-Hazardous | 39H 74B PROVIDE CAPACITY PLATE | $1,000 | $0 | May 30, 1991 |