ECB violations
200-216 West 75 Street, Manhattan • Block 01166 • Lot 0035
75 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Aug 14, 2023 | 39520547X | RESOLVE | CLASS - 2 | CD5 NON CONFORMING. MISSING ADDITIONAL TIEBACKS, NOT PERPENDICULAR TO THE FACE OF BUILDING. PARAPET CLAMPS. NOT VERTI... | $0 | $0 | Nov 16, 2023 |
| Aug 14, 2023 | 39520549J | RESOLVE | CLASS - 1 | WORK IN PROGRESS OBSERVE SUSPENDED SCAFFOLD. AND USE AT EXPOSURE 1. UPON REQUEST TO RIGGING FOREMAN (JUAN OLVEIRA) FO... | $10,000 | $0 | Jun 27, 2024 |
| Aug 14, 2023 | 39520553M | RESOLVE | CLASS - 1 | FAILURE TO PROTECT. LIFELINES FROM SHARP EDGES AND ABRASION CAUSING A HAZARDOUS CONDITION FOR WORKERS AND PERSONNEL. ... | $2,530 | $0 | Nov 12, 2024 |
| Aug 14, 2023 | 39520552K | RESOLVE | CLASS - 1 | OBSERVED SUSPENDED SCAFFOLD IN PLACE AND IN USE AT EXPOSURES 1 AND 4 STIRRUPS. ARE PLACED AT 4'5'' AND 4'-7 AND A HAL... | $2,500 | $0 | Jun 27, 2024 |
| Aug 14, 2023 | 39520548H | RESOLVE | CLASS - 1 | AT TIME OF INSPECTION. I OBSERVE SUSPENDED SCAFFOLDS IN PLACE ANY NEWS. I EXPOSURE ONE. 2. AND 4. LETTER. /REPORT. TO... | $2,500 | $0 | Jun 27, 2024 |
| Nov 5, 2021 | 35631606N | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.AT TIME OF INSPECTION NOTED APPROX 1'X41'.SECTION OF WIRE LATH ... | $0 | $0 | Feb 3, 2022 |
| Jul 13, 2020 | 35538530J | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING WALLS FACADE AND APPURTENANCES NORTH ELEVATION EXPOSURE TWO OBSERVED DEFECTIVE STONE WOR... | $1,250 | $0 | Sep 17, 2020 |
| Jun 17, 2020 | 35492219X | RESOLVE | CLASS - 1 | BC3307.6.5.1-SAFE CONDITION OF SIDEWLAK SHED AT THE TIME OF MY INSPECTION I OBSERVED A POTENTIALLY UNSAFE CONDITION I... | $0 | $0 | Aug 27, 2020 |
| Jul 24, 2019 | 35408844R | RESOLVE | CLASS - 1 | FAILUE TO MAINTAIN BUILDING EXTERIOR WALLS/FACADES AND APPURTENANCES ROOF (SOUTH SECTION) WEST AND NORTH FACING PARAP... | $0 | $0 | Sep 26, 2019 |
| May 29, 2018 | 38262401H | RESOLVE | CLASS - 2 | 97R01 NOUVEAU WAS OPERATING ELEVATOR DEVICE # 1P16890 WITHOUT A CERTIFICATE OF COMPLIANCE. | $0 | $0 | Nov 29, 2018 |
| Aug 10, 2017 | 35264706Z | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN EXTERIOR BUILDING.NORTH ELEVATION EXP.2.A/C UNITS MISSING BRACKETS-2ND FL CHIPPED LIME STONE EXPO... | $0 | $0 | Jan 25, 2018 |
| Aug 10, 2017 | 35264146J | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN EXTERIOR BLDG.NORTH ELEV EXP2 A/C UNITS MISSING BRACKETS 2ND FL CHIPPED LIMESTONE EXPOSED ANCHOR ... | $0 | $0 | Sep 28, 2017 |
| Jul 30, 2012 | 34954249Y | RESOLVE | CLASS - 2 | FAILURE TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS.UPON INSPEC AS NOTED ON ACTIVE CONSTR... | $1,200 | $0 | Oct 25, 2012 |
| Dec 17, 2010 | 38214123K | RESOLVE | CLASS - 2 | 60Q03,64M07,70O02,77Q03.(64M07)PROVIDE NYC DEVICE # TAG ON CONTROLLER & MAIN MACHINE.(77Q03)INSTALL GUARD FOR LIGHT U... | $250 | $0 | Feb 10, 2011 |
| Nov 16, 2010 | 38213939Z | RESOLVE | CLASS - 2 | 01L10,02L10,52K10,05X10,32H11,17H11,17D06,97B10,59J01,70O02,70Z01,79Q03 0102L-INAUDIBLE 52K-BOYGE DEVELOPING LUBE OR ... | $500 | -$500 | Jan 6, 2011 |
| Oct 1, 2008 | 34700470N | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD ALL PERSONS AND PROPERTY AFFECTED BY CONSTRUCTIONOPERATIONS NOTED WHILE DISMANTLING SHED NO FLAG... | $2,400 | $0 | Sep 3, 2009 |
| Jun 24, 2008 | 38186205Z | RESOLVE | Non-Hazardous | 10,17H11.38O02.44B07.86M05.61O02.84B07.11B10.66O02. 10,17H CAR DOOR GIBS WORN & SB WORN NEW GIBS 38O DIRTY DEBRISIS F... | $350 | $0 | Aug 14, 2008 |
| May 6, 2008 | 38184451P | RESOLVE | Non-Hazardous | 16M07. 16M PROVIDE MISSING BRACKET ON THE 2ND FL HOISTWAY DOOR | $350 | $0 | Jun 26, 2008 |
| May 6, 2008 | 38183824Y | RESOLVE | Non-Hazardous | 16M07 16M PROVIDE MISSING BRACKET ON TOP OF 1ST & 2ND FL HOISTWAY DOORCU ITEM YOU CAN USE FINGERS TO OPEN HOISTWAY DO... | $800 | $0 | Jun 26, 2008 |
| May 6, 2008 | 38184450N | RESOLVE | Non-Hazardous | 16M PROVIDE MISSING BRACKET ON TOP 1ST FL HOISTWAY DOOR CU ITEM TO FITCU CALL D.SMITH AT 212-566-5544 TO LIFT CU | $800 | $0 | Jun 26, 2008 |
| Apr 16, 2008 | 34636069N | RESOLVE | Hazardous | WORK DOESN'T CONFORM TO APPROVED PLAYS/ DESIGN DRAWINGS-LIFE LINES ARE NOT INDEPENDENT. REMEDY: CONFORM TO APPROVED P... | $500 | $0 | Jun 12, 2008 |
| Oct 17, 2007 | 34605799N | RESOLVE | Hazardous | WORKERS ON SCAFFOLD W/O A CERTIFICATE OF FITNESS LICENSED RIGGER FAILED TO ENSURE SCAFFOLD WORKER NOT MINIMUM REQUIRE... | $1,500 | $0 | Jul 18, 2008 |
| Aug 16, 2007 | 34496079P | RESOLVE | Hazardous | NO TOE BOARD ON A 2 POINT SUSPENDED SCAFFOLD. NO RECORD OF THE DAILY INSPECTION OF THE SCAFFOLDS PERFORMED BY AN AUTH... | $5,000 | $0 | Jul 18, 2008 |
| Aug 16, 2007 | 34496078N | RESOLVE | Hazardous | USING HOSTING EQUIPMENT IN AN UNSAFE MANNER NOTED: INSUFFICIENT COUNTER WEIGHTS. OUTRIGGER EXTEND +/- 6'TO 12' TO COU... | $4,500 | $0 | Jul 18, 2008 |
| Mar 13, 2007 | 32050567P | RESOLVE | Non-Hazardous | B4A/48A/50/50A/50B/50C/50D/.50-BAROMETER NOT WORKING.50A-COVERS MISSING IN CONTROLS.50B-DEBRIS IN BOILER ROOM.50C-HOL... | $180 | $0 | May 10, 2007 |
| Mar 13, 2007 | 32050568R | RESOLVE | Non-Hazardous | 50/50A/50B/B4A/.50-MISSING BACKFLOW PREVENTOR ON WATER FEED LINE.50A-MISSING BLOW DOWN PIPING ON RELIEF VALVE FOR COI... | $180 | $0 | May 10, 2007 |
| Feb 6, 2007 | 38163188Y | RESOLVE | Non-Hazardous | 16P16,44D06,03B10.16-P-PROVIDE ACCESS TO BASEMENT.44-PROPERLY SECURE HOLE NEXT TO GOVERNOR.03-RUBBING-THUMPING NOISE ... | $350 | $0 | Mar 29, 2007 |
| Feb 18, 2004 | 34428140K | RESOLVE | Non-Hazardous | OCCUPANCY CONTRARY TO THAT ALLOWED BY CERTIFICATE OF OCCUPANCY #100117963 WHICH INDICATES ON FIRST FL COCKTAIL BAR NO... | $400 | $0 | Jul 15, 2004 |
| Feb 18, 2004 | 34428141M | RESOLVE | Non-Hazardous | OPERATION OF A PLACE ASSEMBLY WITHOUT A CURRENT PERMIT NOTED ON FIRST FL LEVEL COCKTAIL BAR CONVERTED TO EATING & DRI... | $100 | $0 | Jul 15, 2004 |
| Nov 21, 2003 | 38143148L | RESOLVE | Non-Hazardous | 10F06/05B07/38M07/67F07 10 SECURE CAR DOWN GIBS 05 ATTAIN FULL OPEN 38-INSTALL MISSING OUTRIGGER 07 ELIMINATE CAR BOU... | $350 | $0 | Jan 8, 2004 |
| Nov 7, 2003 | 38143140R | RESOLVE | Non-Hazardous | 55L10,05I11. 55-ELIMINATE EXCESSIVE BINDING,VIBRATION AND NOISE FROM MACHINE. 05-REPAIR OR REPLACE CAR GATE | $350 | $0 | Jan 8, 2004 |
| Nov 3, 2003 | 38143134K | RESOLVE | Non-Hazardous | 66P07,29D11,16P07. 66-INSTALL PIT LADDER 29-COVER LIMIT BOX 16-PROVIDE ACCESS TO ORGAN BOTTOM EXIT DOOR | $350 | $0 | Dec 18, 2003 |
| Nov 3, 2003 | 38143135M | RESOLVE | Non-Hazardous | 55L10,30D11,16D10. 55-REPAIR PACKING GLAND AT GEAR BOX IN SOUTH EAST CORNER/ 30-COVER LIMIT BOX. 16-REPAIR SOUTH EXIT... | $350 | $0 | Dec 18, 2003 |
| Jan 31, 2003 | 34381108P | RESOLVE | Non-Hazardous | HAVING INSTALLED AN AWNING WITHOUT A PERMIT. HAVING INSTALLED A SIGN WITHOUT A PERMIT. REMEDY: REMOVE ILLEGAL WORK SI... | $800 | $0 | Jun 5, 2003 |
| Jan 31, 2003 | 34381112H | RESOLVE | Non-Hazardous | HAVING AWNING SIGNAGE NOT LIMITED THE NAME AND ADDRESS OF THE ESTABLISHMENT. REMEDY: REMOVE ILLEGAL WORK SIGNAGE. | $800 | $0 | Jun 5, 2003 |
| Jan 31, 2003 | 34381102Y | RESOLVE | Non-Hazardous | HAVING INSTALLED AN AWNING WITHOUT A PERMIT. HAVING INSTALLED A SIGN WITHOUT A PERMIT. REMEDY: REMOVE ILLEGAL WORK SI... | $800 | $0 | Jun 5, 2003 |
| Jan 31, 2003 | 34381107N | RESOLVE | Non-Hazardous | HAVING INSTALLED AN AWNING WITHOUT A PERMIT. HAVING INSTALLED A SIGN WITHOUT A PERMIT. REMEDY: REMOVE ILLEGAL WORK SI... | $800 | $0 | Jun 5, 2003 |
| Jan 31, 2003 | 34381114L | RESOLVE | Non-Hazardous | FAILRUE TO COMPLY WITH LOCAL LAW 58/87. NOTED: ALTERATION # 9FOR FRONT AND MANSORY) AND AFFECTED ENTRY PATHWAY RISE A... | $0 | $0 | Jun 5, 2003 |
| Jan 31, 2003 | 34381106L | RESOLVE | Non-Hazardous | HAVING INSTALLED AN AWNING WITHOUT A PERMIT. HAVING INSTALLED A SIGN WITHOUT A PERMIT. REMEDY; REMOVE ILLEGAL WORK SI... | $800 | $0 | Jun 5, 2003 |
| Jan 31, 2003 | 34381105J | RESOLVE | Non-Hazardous | HAVING INSTALLED AN AWNING WITHOUT A PERMIT. HAVING INSTALLED A SIGN WITHOUT A PERMIT. REMEDY: REMOVE ILLEGAL WORK SI... | $800 | $0 | Jun 5, 2003 |
| Jan 31, 2003 | 34381103X | RESOLVE | Non-Hazardous | HAVING INSTALLED AN AWNING WITHOUT A PERMIT. HAVING INSTALLED A SIGN WITHOUT A PERMIT. REMEDY: REMOVE ILLEGAL WORK SI... | $800 | $0 | Jun 5, 2003 |
| Jan 31, 2003 | 34381101M | RESOLVE | Non-Hazardous | HAVING INSTALLED AN AWNING WITHOUT A PERMIT. HAVING INSTALLED A SIGN WITHOUT PERMIT. REMEDY; REMOVE ILLEGAL WORK SIGN... | $800 | $0 | Jun 5, 2003 |
| Jan 31, 2003 | 34381104H | RESOLVE | Non-Hazardous | HAVING A INSTALLED AN AWNING WITHOUT A PERMIT. HAVING INSTALLED A SIGNE WITHOUT A PERMIT. REMEDY: REMOVE ILLEGAL WORK... | $800 | $0 | Jun 5, 2003 |
| Jan 31, 2003 | 34381110Y | RESOLVE | Non-Hazardous | HAVING AWNING SIGNAGE NOT LIMITED TO THE NAME AND ADDRESS OF THE ESTABLISHMENT. REMEDY: REMOVE ILLEGAL WORK SIGNAGE. | $800 | $0 | Jun 5, 2003 |
| Jan 31, 2003 | 34381111X | RESOLVE | Non-Hazardous | HAVING AWNING SIGNAGE NOT LIMITED TO THE NAME AND ADDRESS OF THE ESTABLISHMENT. REMEDY: REMOVE ILLEGAL WORK SIGNAGE. | $800 | $0 | Jun 5, 2003 |
| Oct 21, 2002 | 34342741Z | RESOLVE | Hazardous | FAILURE TO POST PERMIT FOR WORK AT PRIMISES NO PERMIT POSTED AT TIME OF INSPECTIN. REMEDY; POST PERMIT. | $130 | $0 | Jan 9, 2003 |
| Jul 21, 2001 | 34296856Y | RESOLVE | Hazardous | FAILURE TO PROVIDE AT LEAST TWO MEANS OF EGRESS; IN THAT - EXIT- SIGN AT BASEMENT DINECTS PEDESTIAN TRAFFIC TO A DEAD... | $0 | $0 | Dec 6, 2001 |
| Dec 8, 1999 | 34234422N | RESOLVE | Non-Hazardous | FAILURE TO AMEND PLANS TO SHOW LOCATION OF EMERGENCY LIGHTING , NITED: AT CELLAR EATING AND DRINKING ESTABLISMENT APP... | $350 | $0 | Feb 11, 2000 |
| Nov 9, 1999 | 38092278M | RESOLVE | Non-Hazardous | 40F,37X,15F. REPAIR NOISY GOVEERNOR, REPAIR DEFECTIVE CONTACTOR FOR GENERATOR, ELIMINATE IN HANGERS. | $0 | $0 | Dec 30, 1999 |
| Nov 9, 1999 | 38092276Z | RESOLVE | Non-Hazardous | 60I, 3D,15F. RENEW BUFFER STAND, REPAIR COMMUNICATIONS FROM CAB. ELIMINATE EXCESS IN HANGERS. | $0 | $0 | Dec 30, 1999 |