ECB violations
Rivr Schl W Side Bright Horizons, Manhattan • Block 01171 • Lot 0063
59 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Jun 10, 2026 | 39192076Z | ACTIVE | CLASS - 2 | NO IMMEDIATELY HAZARDOUS CONDITIONS OBSERVED AT TIME OF REINSPECTION. PARKING GARAGE REPAIRS APPEAR TO HAVE BEEN CORR... | $1,250 | $1,250 | Oct 8, 2026 |
| Nov 17, 2023 | 39099653N | RESOLVE | CLASS - 2 | NOTED: THE EMERGENCY LIGHTS AND EXIT SIGNS ARE INOPERATIVE IN VARIOUS AREAS THROUGHOUT THE CELLAR AND SUB CELLAR LEVE... | $0 | $0 | Jan 25, 2024 |
| Nov 17, 2023 | 39099654P | RESOLVE | CLASS - 1 | NOTED: AT TIME OF INSPECTION, OBSERVED MULTIPLE DOORS WITH YELLOW CAUTION TAPE AFFIXED ACROSS THEM. ALSO, AT SUB-CELL... | $1,250 | $0 | Feb 22, 2024 |
| Nov 17, 2023 | 39099652L | ACTIVE | CLASS - 1 | THE GARAGE CEILING SLABS HAS BI-DIRECTIONAL RUNNING CRACKS AND SPALLING MASONRY IN VARIOUS AREAS THROUGHOUT. CELLAR L... | $1,250 | $0 | Feb 22, 2024 |
| Jun 14, 2021 | 35554169H | ACTIVE | CLASS - 1 | PERMANENT DWELLINGS USED/CONVERTED FOR OTHERS THAN PERMANENT-RESIDENTIAL PURPOSED DEPT OF BUILDINGS RECORDS INDICATES... | $47,000 | $0 | Jan 6, 2022 |
| Jun 14, 2021 | 35554170P | ACTIVE | CLASS - 1 | BC 907.2.8 FAILURE TO PROVIDE FIRE ALARM SYSTEM FOR TRANSIENT USE.CLASS "J" FOR TRANSIENT USE AT APT P12B.PREVIOUS EC... | $6,250 | $0 | Jan 6, 2022 |
| Feb 13, 2020 | 37018190X | RESOLVE | CLASS - 2 | FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 8C REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WA... | $1,250 | $0 | May 28, 2020 |
| Jan 28, 2020 | 35465896J | RESOLVE | CLASS - 2 | PERMANENT DWELLING USE/CONVERTED FOR OTHER THAN PERMANENT-RESIDENTIAL PURUPOSES.DEPARTMENT OF BUILDINGS RECORDS INDIC... | $2,500 | $0 | Dec 10, 2020 |
| Jan 28, 2020 | 35465897L | RESOLVE | CLASS - 1 | BC90728-FAILURE TO PROVIDE FIRE ALARM SYSTEM FOR TRANSIENT USE AT APT#C17A.CLASS "J".REMEDY:DISCONTINUE ILLEGAL OCCUP... | $2,500 | $0 | Dec 10, 2020 |
| Dec 7, 2019 | 39014057L | RESOLVE | CLASS - 2 | WORK WITHOUT A PERMIT. AT TIME OF INSPECTION, IN APARTMENT C3B OBSERVED THE REMOVAL OF A BATHROOM LIGHT FIXTURE, AND ... | $1,250 | $0 | May 21, 2020 |
| Dec 7, 2019 | 39014058N | RESOLVE | CLASS - 2 | WORK WITHOUT A PERMIT. AT TIME OF INSPECTION, IN APARTMENT C3B OBSERVED THE REMOVAL(CUTTING) OF COPPER PIPING IN THE ... | $1,250 | $0 | May 21, 2020 |
| Feb 13, 2018 | 35311286K | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG IN A CODE COMPLIANT MANNER LACK OF EMERGENCY LIGHTING FOR EXISS,EXIT DISCHARGES & PUBLIC COR... | $0 | $0 | Apr 12, 2018 |
| Nov 3, 2017 | 35255633M | RESOLVE | CLASS - 1 | FILED A CERTIFICATE FORM,APPLICATION ETC CONTAINING A MATERIAL FALSE STATEMENT(S).NOTED:THE OWNER/REPRESENTATIVE MADE... | $4,800 | $0 | Apr 5, 2018 |
| Nov 3, 2017 | 35256548M | RESOLVE | CLASS - 1 | FILED A CERTIFICATE FORM,APPLICATION ETC CONTAINING A MATERIAL FALSE STATEMENT(S).NOTED:THE OWNER/REPRESENTATIVE MADE... | $4,800 | $0 | Apr 5, 2018 |
| Nov 3, 2017 | 35255627X | RESOLVE | CLASS - 1 | FILED A CERTIFICATE FORM,APPLICATION ETC CONTAINING A MATERIAL FALSE STATEMENT(S).NOTED:THE OWNER/REPRESENTATIVE MADE... | $4,800 | $0 | Apr 5, 2018 |
| Apr 15, 2015 | 35128144J | RESOLVE | CLASS - 2 | COMBUSTIBLE MATERIALS IN CORRIDORS. NOTE: THRU-OUT THE MAIN CORRIDOR FURNITURE, BACKPACKS, TOYS, STROLLERS & CLOTHING... | $250 | $0 | Jul 16, 2015 |
| Jan 9, 2015 | 38230910J | RESOLVE | CLASS - 2 | 97X17 - DEVICE #1P37482 CEASE USE PENDING DOB INVESTIGATION/INSPECTION | $0 | $0 | Mar 5, 2015 |
| Jan 9, 2015 | 38230909M | RESOLVE | CLASS - 1 | FAILURE TO FOLLOW WORK PROCEDURES AND THE CAUTIONS FOR REMOVING AN ELEVATOR FROM SERVICE TO PROVIDE ACCESS.ON FRIDAY ... | $0 | $0 | Apr 23, 2015 |
| Jan 9, 2015 | 38230911L | RESOLVE | CLASS - 2 | 97X17 - DEVICE #1P37483 CEASE USE TO THE PUBLIC PENDING RESULTS OF DEVICE #1P37482. | $0 | $0 | Mar 5, 2015 |
| Jul 9, 2014 | 35095957Z | RESOLVE | CLASS - 2 | SIDEWALK SHED DOES NOT MEET CODE SPECIFICATIONS. SHED LOCATED SOUTH SIDE OF W 62 AT DEAD END APPROX 35' HAS COLLAPSED... | $2,400 | $0 | Oct 23, 2014 |
| Apr 21, 2014 | 38230978X | RESOLVE | CLASS - 2 | 39X10(39-X-10)CARTOP INSPECTION IS NOT WORKING IN THE DOWN DIRECTION | $500 | $0 | Jun 5, 2014 |
| Apr 21, 2014 | 38230977Y | RESOLVE | CLASS - 2 | 05X01(05-X-01)ZONE LOCK NEED TO BE ADJUSTED | $500 | $0 | Jun 5, 2014 |
| Apr 4, 2014 | 38229674Z | RESOLVE | CLASS - 2 | 05X01 39M07 99BB05 100P17. 05X01-ADJUST ZONE LOCK. 39M07-ANTI-SPIN CABLE ON HOIST CABLE NEED CROSBY ON BOTH ENDS. 99B... | $0 | -$500 | Nov 24, 2017 |
| Feb 26, 2013 | 35001735N | RESOLVE | CLASS - 1 | FAILURE TO TAKE REQUIRED MEASURES TO SECURE PUBLIC SAFETY FROM UNSAFE FACADES.NOTED: NO SAFETY MEASURES WERE ERECTED ... | $0 | $0 | Aug 22, 2013 |
| Feb 26, 2013 | 35001734L | RESOLVE | CLASS - 1 | FAILURE TO TAKE REQUIRED MEASURES TO SECURE PUBLIC SAFETY OF UNSAFE FACADES NOTED: NO SAFETY MEASURES ARE IN PLACE DE... | $0 | $0 | Aug 22, 2013 |
| Nov 22, 2011 | 38218653X | RESOLVE | CLASS - 2 | 39O02,70O02,08V01 08V01-FLOORS 37,38 AND 39. | $500 | $0 | Jan 12, 2012 |
| May 10, 2011 | 38215564K | RESOLVE | CLASS - 2 | 39P16,70O02,80B4.(80B)SHORTEN CULT ROPES. | $500 | $0 | Jun 30, 2011 |
| Nov 8, 2007 | 34619367R | RESOLVE | Hazardous | SEC. 27-371(I) ILLEGAL HARDWARE. CELLAR: NEAR COLUMN #47 - EMERGENCY EGRESS DOOR HAS A KEY LOCK INSTALLED. SUBCELLAR:... | $350 | $0 | Mar 6, 2008 |
| Nov 8, 2007 | 34619366P | RESOLVE | Hazardous | EXIT DOOR: TOTAL OBSTRUCTION. CELLAR: NEAR COLUMN #47 - EMERGENCY EGRESS DOOR MARKED W/AN EMERGENCY PUSH BAR & A LIT ... | $480 | $0 | Mar 6, 2008 |
| Apr 20, 2006 | 38158731K | RESOLVE | Non-Hazardous | 66-O-02/66-O-02-REMOVE OLD CABLES & OTHER CELLAR DEBRIS FROM PITS# 1,2,3. | $0 | $0 | Jun 8, 2006 |
| Oct 24, 2005 | 38155975N | RESOLVE | Non-Hazardous | 83X10. (83-X-10) RESTORE TO PROPER SERVICE SO THAT THE ELEVATOR MAY BE INSPECTED BY D.O.B ELEVATOR INSPECTOR. | $0 | $0 | Dec 8, 2005 |
| Feb 16, 2005 | 38151166P | RESOLVE | Non-Hazardous | 02L10. (02) IN CAB ALARM SYSTEM FOR DEVICE NUMBER 1P37527 IS DEFECTIVE- NO AUDIO ON ACTIVATION. | $350 | $0 | Apr 7, 2005 |
| Feb 7, 2005 | 38151177K | RESOLVE | Non-Hazardous | 59Q03/55O02/71Q03/66O02/38O02/52O02/05O02/16O02/11I10 59-MOTOR ROOM LIGHTS UNGUARDED 55-CLEAN MAIN MACHINE 71-UNDER C... | $0 | $0 | Mar 24, 2005 |
| Feb 7, 2005 | 38151176Z | RESOLVE | Non-Hazardous | 59Q03/55O02/38O02/52O02/05O02/16O02/66O02 59-GUARD MOTOR ROOM LIGHTS ALSO SOME LIGHTS ARE OUT 55-CLEAN MAIN MACHINE 3... | $0 | $0 | Mar 24, 2005 |
| Jun 11, 2004 | 38147198H | RESOLVE | Non-Hazardous | 51K02. | $0 | $0 | Jul 29, 2004 |
| Oct 15, 2003 | 38142586R | RESOLVE | Non-Hazardous | 55E10/02X07/01B07/16B10 (55)ELIMINATE EXCESSIVE NOISE FROM MACHINE GLAND BEARING(02)PROVIDE ALARM FOR ALARM BUTTON(01... | $350 | $0 | Aug 12, 2004 |
| Oct 15, 2003 | 38142587Z | RESOLVE | Non-Hazardous | 55E10/16B7 55-ELIMINATE EXCESSIVE NOISE FROM MACH.COUPLING 16-INSTALL MISSING FASCIA BELOW BOTTOM TERMINAL DOOR. | $350 | $0 | Sep 30, 2004 |
| Oct 15, 2003 | 38142588K | RESOLVE | Non-Hazardous | 56E10/41B7/2X7/32B7/84F10 56-ELMINATE VIBRATION & NOISE FROM FRONT OF DEVICE MOTOR 41-PROVIDE MEANS TO RUN CAR ON INS... | $350 | $0 | Sep 30, 2004 |
| Oct 9, 2003 | 38142584N | RESOLVE | Non-Hazardous | 03D06/ 24X10/ 38D07/ 73B07/ 66M07/ 69M07/ 03=SECURE RETURN PANEL (FRONT WALL OF CAB, CONTAINING CAR STATION) TO ELIMI... | $350 | $0 | Aug 12, 2004 |
| Oct 9, 2003 | 38142583L | RESOLVE | Non-Hazardous | 03B10/ REPAIR INTERCOM SYSTEM. - REPAIR TRAV. LANTERNS. | $350 | $0 | Aug 12, 2004 |
| Oct 6, 2003 | 38142582J | RESOLVE | Non-Hazardous | 57Y10/ 52#11/ 03B07/ 73B07/ 56E10/ 84L10/ 57=REPAIR DRIVE SHEAVE BEARING SEAL TO STOP LEAK. 52=REPLACE WORN, DEFECTIV... | $350 | $0 | Aug 12, 2004 |
| Sep 23, 2003 | 38141521L | RESOLVE | Non-Hazardous | 51J07,14M07,38I07,31M11,52D06. (51) PROVIDE REQUIRED TOP RUNBY AT CUT. BUFTER. (14) INSTALL REQ CAB MIRROR (38) REPLA... | $350 | $0 | Nov 13, 2003 |
| Sep 23, 2003 | 38141520J | RESOLVE | Non-Hazardous | 51#11,14M07,52D06.51-REPLACE WORN, RUSTED & DEFECTIVE HOIST ROPES. 14- INSTALL REQ, MIRROR IN CAB. 52- CUT EXCESS GOV... | $350 | $0 | Nov 13, 2003 |
| Sep 9, 2003 | 38141514N | RESOLVE | Non-Hazardous | 51,#, 11 51 REPLACE WORN RUSTED DEFECTIVE HOIST ROPES | $350 | $0 | Oct 31, 2003 |
| Aug 28, 2003 | 38141504J | RESOLVE | Non-Hazardous | 03J07,07D06,28F10.03-RESTORE TRAV LANT ARROWS 07-SECURE PANA 40 EDGE 28-DOOR SLAMS | $350 | $0 | Oct 16, 2003 |
| Aug 28, 2003 | 38141505L | RESOLVE | Non-Hazardous | 51#11,03J07. 51-REPLACE WORN, RUSTED AND DEFECTIVE HOIST ROPES. 03-RESTORE TRAV LANT ARROWS | $350 | $0 | Oct 16, 2003 |
| Feb 11, 2000 | 38094169M | RESOLVE | Non-Hazardous | 75R05.75R05- PROPERLY PERFORM THE 5 YEAR TEST AND FILE WITH THE DEPT. OF BUILDING | $180 | $0 | Mar 30, 2000 |
| May 25, 1999 | 38086977K | RESOLVE | Non-Hazardous | 37A 46H 37 PROPERLY WIRE 46 REPAIR | $350 | $0 | Aug 12, 2004 |
| Jan 17, 1995 | 34110036K | RESOLVE | Hazardous | FAILURE TO PERFORM ADEGUATE HOUSE KEEPING ON FLOORS 31 THRU 39 INSUSIVE,EXCESS MASONING DEBRIS IN TOWER"A".REMEDY:PER... | $1,000 | $0 | Feb 23, 1995 |
| Jan 17, 1995 | 34110034R | RESOLVE | Unknown | UNSAFE STORAGE OF MATERIALS LEGS THAN TWO FEET FROM BULDING EDGE. MASONRY MATERIAL STORED AT EDGE OF BUILDING AT THE ... | $500 | $0 | Feb 23, 1995 |