Issued Violation Status Severity Description Penalty Balance due Hearing
Aug 1, 2018 37012194X RESOLVE CLASS - 2 FAILURE TO FILE ACCEPTABLE AMENDED CYCLE 8A REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL FA... $1,250 $0 Apr 4, 2019
May 22, 2017 35258644L RESOLVE CLASS - 2 SIDEWALK SHED DOES NOT MEET CODE SPECS.NOTED:AT TIME OF INSPECTION SIDEWALK SHED DOES NOT EXTEND 20FT PAST THE BUILDI... $2,400 $2,400 May 24, 2018
May 12, 2016 38242293L RESOLVE CLASS - 2 59U15-PROVIDE BRAKE MAINTENANCE TAG AS PER A17.1-2003 AND APPENDIX K3 8.6.4.6 $0 $0 Jun 30, 2016
Sep 28, 2010 38212346Z RESOLVE CLASS - 2 56Y10,56Y13,68M07,40BB10,80B14,32H10,37P16,45P16,46P16.(40BB)SERVICE FIRE EXTINGUISHER. $0 $0 Nov 18, 2010
Sep 28, 2010 38212345R RESOLVE CLASS - 2 80B14,70Q07,68M07,59B07,48BB10,16B10,39Q07,37P16.(70Q)PROVIDE COVER FOR SUMP-PUMP IN PIT.(59B)PROVIDE PROPER COTTER P... $0 $0 Nov 18, 2010
Sep 28, 2010 38212347K RESOLVE CLASS - 2 56Y10,56Y13,68M07,40BB10,80B14,39O02,37P16,45P16,48P16.(40BB)SERVICE FIRE EXTINGUISHER IN M.R. $0 $0 Nov 18, 2010
Aug 23, 2010 34860788X RESOLVE CLASS - 2 BC3310.3 FAILURE TO HAVE SITE SAFETY PLAN & PROGRAM 1ST STY OCCUPIED BLDG IS UNDER FACADE ALT SCAFFOLD IS BEING INSTA... $0 $0 Oct 19, 2010
Aug 4, 2009 38205300H RESOLVE CLASS - 2 97E1.10 97E 1.10 SOMETHING DRAGGING IS SCRAPPING ADJUST REPAIR REMOVE AND CLUTCH CLIPPING $0 $0 Sep 24, 2009
Jan 9, 2008 34418629R RESOLVE Hazardous LOCAL LAW REPORT FILED AS "UNSAFE" UNSAFE CONDITION EXISTS & NO MEASURES TAKEN TO SECURE SAFETY OF PUBLIC AS PER 27-1... $800 $0 Sep 24, 2009
Oct 4, 2007 38178560N RESOLVE Non-Hazardous 58O12,58O02,58B10,55O02,59Q07,84X07,38O02,38L07,64L07,66O02,36M07,51T12. 58-B BRAKE PADS OILED, REPLACE CLEAN PULLEY;... $0 $0 Nov 29, 2007
Aug 14, 2006 38160971M RESOLVE Non-Hazardous 15I11,08V01,84J01,43L10,84L10,05J01. (15-I-11) REPLACE CERTIFICATE FRAME. (08-V-01) RUMBLING NOISE WHEN ELEVATOR RUNN... $350 $0 Sep 28, 2006
Jul 11, 2006 38159547P RESOLVE Non-Hazardous 84,L,10-85,U,05-11,L,10 84-L-10-REPAIR FAN 11-L-10-BUTTONS DO NOT WORKSOMETIMES $0 $0 Aug 31, 2006
Jul 10, 2006 38159546N RESOLVE Non-Hazardous 28-Q-07,84-L-10/84-L-10-REPAIR FAN $0 $0 Aug 24, 2006
Mar 6, 2006 38157641M RESOLVE Non-Hazardous 83L10. (83-L-10)ELEVATOR OUT OF SERVICE REPAIR/RESTORE TO SERVICE SO PROPER INSPECTION MAY BE PERFORMED BY D.O.B. INS... $0 $0 Apr 20, 2006
Jul 18, 2005 34484126K RESOLVE Non-Hazardous WORK W/O A PERMIT-HAZARDOUS. WORK NOTED: THE CONSTRUCTION OF FULL HEIGHT SHEETROCK PARTITION WALLS, TWO BEDROOMS, ONE... $500 $0 Sep 1, 2005
Mar 27, 2002 34316073N RESOLVE Non-Hazardous FAILURE TO MAINTAIN EXTERIOR WALL. DEFECT IS BRICK CHIMNEY AT REAR MISSING AND LOOSE COUPLINGS. TOP OF CHIMNEY. REMED... $800 $0 May 16, 2002
Feb 6, 2001 38111210R RESOLVE Non-Hazardous 74B15-COUNTER WEIGHT TOUCHING BUFFOR SPRING PROPERLY SHORTER ROPE TO PROVIDE PROPER CLEARANCE. $0 $0 Mar 29, 2001
Feb 5, 2001 38111208H RESOLVE Non-Hazardous 39##, 46##. 39 & 46- INSTALLED NEW SHEAVE & HOIST ROPE WITHOUT PERMIT. FILE FOR & OBTAIN PERMIT- TO BE TESTED BY THIS... $0 $0 Mar 22, 2001
Feb 5, 2001 38111207X RESOLVE Non-Hazardous 73##. 73-OPERATING ELEVATOR WITH OUT AN EQUIPMENT USE PERMIT (CERT.) CALL 212-312-8745 TO ARRANGE FOR APPOINTMENT TO ... $180 $0 Mar 29, 2001
Jan 30, 2001 38111201P RESOLVE Hazardous 47J01,39H08,46H12,18Q12. 46H12 UNDER SIZE ROPES. 39H08 SHEOVE GROOVE ARE WORN REPAIR SHEAVE. 18Q12 INTERLOCK COVERS B... $500 $0 Apr 12, 2001
Mar 17, 1999 38085453P RESOLVE Non-Hazardous 47H. $180 $0 Jun 3, 1999
Mar 17, 1999 38085452N RESOLVE Non-Hazardous 48H,55L,14M. $180 $0 Jun 3, 1999
May 10, 1998 38074583J RESOLVE Non-Hazardous 57O,39H,50Y,74M,40O,22D,03X,07L,08J, 03X-FAN 74M-2 YEAR TEST TAG. $0 $0 Jul 27, 1998
May 10, 1998 38074582H RESOLVE Non-Hazardous 50Y,39Q,22D,03X,08L,57O,15X,40O,74M, 39Q-ECCENTRIC UNDER MACHINE SHEAVE BENT CABLE GUARD 15X-DOOR CLOSURE 03X-FAN IN ... $0 $0 Jul 27, 1998
Sep 24, 1991 34062938X RESOLVE Non-Hazardous WORK WITHOUT PERMIT: NOTED: COMBINING APARTMENTS 2C & 2D ENLARGING BY ONE ROOM 2C - REDUCING APARTMENT 2D. LOCATION 2... $0 $0 Nov 4, 1991
Dec 8, 1988 34019152K RESOLVE Non-Hazardous OCCUPANCY CONTRARY TO THAT ALLOWED BY BUILDING DEPARTMENT RECORDS INDICATED APT 5C AT 5TH STORY SOUTHWEST SIDE OF BUI... $0 $0 Feb 16, 1989