ECB violations
5-15 West 91 Street, Manhattan • Block 01205 • Lot 0022
25 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Jan 21, 2022 | 35409768Z | RESOLVE | CLASS - 2 | FAILURE TO POST OR DISTRIBUTE SAFE CONSTRUCTION BILL OF RIGHTS.NOTE ATTIME OF INSPECTION OBSERVED EVIDENCE OF ONGOING... | $1,250 | $0 | Sep 1, 2022 |
| Jan 21, 2022 | 35409770H | RESOLVE | CLASS - 2 | FAILURE TO POST OR PROPERLY POST PERMIT FOR WORK AT PREMISES.NOTE AT TIME OF INSPECTION AT AN OCCUPIED MULTI-DWELLING... | $312 | $0 | Sep 1, 2022 |
| Jan 21, 2022 | 35409769K | RESOLVE | CLASS - 2 | FAILURE TO DISTRIBUTE OR POST NOTICE OF TENANT PROTECTION PLAN.NOTE ATTIME OF INSPECTION AT AN OCCUPIED MULT-DWELLING... | $1,250 | $0 | Sep 1, 2022 |
| Sep 18, 2013 | 35033691R | RESOLVE | CLASS - 2 | PERMANENT DWELLING USED/CONVERTED FOR OTHER THAN PERMANENT RESIDENTIALPURPOSES. C/O #74743 INDICATES THAT BLDG SHOULD... | $1,600 | $0 | May 21, 2014 |
| Sep 18, 2013 | 35033692Z | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER: LACK OF A SYSTEM OFAUTOMATIC SPRINKLERS WHERE REQUIRED PER BC 903.... | $500 | $0 | May 15, 2014 |
| Sep 18, 2013 | 35033693K | RESOLVE | CLASS - 1 | SEC. BC 907.2.8 FAILURE TO PROVIDE FIRE ALARM SYSTEM FOR TRANSIENT USE. REMEDY: DISCONTINUE ILLEGAL OCCUPANCY. | $800 | $0 | May 15, 2014 |
| Jul 30, 2012 | 34993183M | RESOLVE | CLASS - 3 | FAILURE TO MAINTAIN. DEFECT IS: CRACKED SPALLING CONCRETE EXPOSING RUSTED REBAR AT VARIOUS LOCATIONS OF FRONT BALCONI... | $200 | $0 | Sep 13, 2012 |
| Jul 23, 2010 | 34852062R | RESOLVE | CLASS - 2 | WORK W/O A PERMIT.WORK NOTED:@ TIME OF INSPECTION THERE IS RENOVATION WORK IN PROGRESS INCLUDING PLUMBING,ELECTRICAL ... | $0 | $0 | Sep 16, 2010 |
| Jun 25, 2009 | 34789462R | RESOLVE | CLASS - 2 | OCCUPANCY CONTRARY TO THAT ALLOWED BY THE C OF O OR BUILDING DEPT RECORDS: OCCUPANCY NOTED: BUILDING HAVING OCCUPIED ... | $3,000 | -$3,000 | Aug 13, 2009 |
| Jun 25, 2009 | 34789463Z | RESOLVE | CLASS - 2 | WORK W/O A PERMIT. WORK NOTED: BUILDING HAVING ERECTED PARTITIONS,PLUMBING,ELECTRICAL TO CREATE 1 BEDROOM BASEMENT AP... | $800 | $0 | Jul 8, 2010 |
| Mar 25, 2009 | 34775201L | RESOLVE | CLASS - 3 | FAILURE TO MAINTAIN BLDG IN CODE COMPLAINT MANNER DEFECTS NOTED SLOPING UNEVEN FLOOR IN THE BATHROOM IN APT # 1H AND ... | $100 | $0 | May 14, 2009 |
| Aug 19, 2008 | 34700655J | RESOLVE | CLASS - 2 | FAILURE TO COMPLY WITH THE COMMISIONERS ORDER TO FILE A CERT OF CORRECTION W/ THE DOB FOR ECB(#3457970U)FOR ILLEGAL A... | $800 | $0 | May 28, 2009 |
| Feb 4, 2008 | 34618676X | RESOLVE | Non-Hazardous | STOP ALL WORK. WORK W/O A PERMIT IN APT #1E NOTED: OBSERVED, WHILE IN PROCESS OF CHANGING OUT KITCHEN FIXTURES,REMOVE... | $500 | $0 | Jul 24, 2008 |
| Aug 6, 2007 | 38168784N | RESOLVE | Non-Hazardous | 84B07,40T07,86U05,55Y10,55O02,51Q03,58J10,38O02,38M07,15M07(PROVIDE ORIGINAL CERT. & FRAME).84B10-INTERCOM NOT WORKIN... | $0 | $0 | Sep 27, 2007 |
| May 23, 2007 | 34579702L | ACTIVE | Non-Hazardous | ALT BULGING OCCUPIED W/O A VALID C OF O . C OF O # 74743 DATED 7-9-74 EXPIRED 10-9-74. REMEDY:OBTAIN VALID C OF O. | $350 | $0 | Jul 24, 2008 |
| May 21, 2007 | 34579701J | RESOLVE | Non-Hazardous | OCCUPANCY CONTRARY TO THAT ALLOWED BY THE CERT OF OCCUPANCY OF BLDG DEPT RECORDS.NOTED:CLASS"A" APT W/ BEDROOM LIVING... | $800 | $0 | Jan 31, 2008 |
| Jan 4, 2007 | 34490634H | RESOLVE | Hazardous | PLUMBING WORK W/O A PERMIT. UPON ENTERING APT 4G SAID ADDRESS I WITNESSED NEW TRAPS FOR KITCHEN & BATHRM, NEW SHOWER ... | $500 | $0 | Jul 19, 2007 |
| Mar 16, 2006 | 38158211R | RESOLVE | Non-Hazardous | 08V01/85BB05/66O02 (08-V-01) FLOOR STOPS NOT LEVEL ADJUST. (85-BB-05) 5 YR TAG EXPIRED PERFORM AND FILE TEST (66-O-02... | $2,500 | $0 | Oct 5, 2006 |
| Feb 27, 2006 | 38151741M | RESOLVE | Non-Hazardous | 83**. 83 RESTORE ELEVATOR BACK TO SERVICE | $350 | $0 | Oct 30, 2008 |
| Nov 8, 2004 | 38149086M | RESOLVE | Non-Hazardous | 8V1/57B10/66Z9/5J1 8-V-1 ADJUST LEVELING 57-B-10 REMOVE FROM MACHINE. 66-Z-9 REMOVE WATER FROM PIT. 5-J-1 ADJUST CAR ... | $350 | $0 | Dec 23, 2004 |
| Feb 24, 2004 | 38145456M | RESOLVE | Non-Hazardous | 41G11/ 33P16/ 66Z9/ 83X10/ 41G11 = 3, 4, 5 & 6 WIRED 83X10 = MAKE REPAIRS AND RESTORE TO SERVICE FOR A FULL INSPECTIO... | $0 | $0 | Apr 15, 2004 |
| Sep 15, 2003 | 38142079M | RESOLVE | Non-Hazardous | 60T07,55Y10,56E10,40T07,38Y02,38Q07,84M07,66Z02. 60- PROVIDE ELEV CO NAME , 56-REPAIR RUMBLING NOISE FROM MOTOR, 38-T... | $0 | $0 | Oct 30, 2003 |
| May 21, 2003 | 38138172P | RESOLVE | Hazardous | 39G12 49I12 79U16 39G12=1,2,3, RECTIFIER AND CONTROLLER FUSES WIRED 79U16=INCORRECT I.D. NUMBER CORRECT NUMBER IS IP3... | $2,500 | $0 | Jul 10, 2003 |
| May 9, 1995 | 38049341M | RESOLVE | Non-Hazardous | 16M,21L,28L,31Q,37G,50F,52I,62M,73U,74Y.50F-16H-2ND FLOOR 21L-PI AND DIAL 31Q-THRU INSTALLATIONS 50F-GRIMDING 52I-BRA... | $1,000 | $0 | Jun 29, 1995 |
| Jan 18, 1991 | 38004523Y | RESOLVE | Non-Hazardous | 73#,73 PERFORM 5 YEAR TEST AND FILE. | $150 | -$150 | Sep 9, 1993 |