ECB violations
Wise Rehabs Complex, Manhattan • Block 01207 • Lot 0050
12 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| May 7, 2025 | 35693740H | ACTIVE | CLASS - 2 | PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATIONS. NOTE: AT TIMEOF INSPECTION OBSERVED AT SIDEWALK SHED PARAPET... | $2,400 | $0 | Feb 5, 2026 |
| Apr 9, 2025 | 39538915X | ACTIVE | CLASS - 2 | FAILURE TO COMPLY WITH CODES 3307.6.2, 3307.6.3, 3307.6.3 AND SECTIONS, CREATING A HAZARDOUS OF POTENTIAL AND EXPOSE ... | $2,430 | $0 | Jun 26, 2025 |
| Mar 27, 2024 | 39109989N | RESOLVE | CLASS - 2 | PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATIONS. NOTE: I OBSERVED A SIDEWALK SHED ERECTED AT EXPO# 1 WITH MIS... | $2,400 | $2,400 | Oct 30, 2025 |
| Nov 16, 2023 | 39523421Y | RESOLVE | CLASS - 2 | AT TIME OF INSPECTION OF 5 STORY BUILDING OBSERVED SIDEWALK SHED IN PLACE MISSING PARAPET PANEL NOT COMPLIANT AS PER ... | $2,400 | $2,400 | Jun 17, 2025 |
| Oct 4, 2023 | 39522327N | RESOLVE | CLASS - 2 | 5 STORY LANDMARK BUILDING, RESPONDING TO SIDEWALK SHED(SWS) COMPLAINT, I OBSERVED SWS AT EXP1, DOES NOT EXTEND 5FEET ... | $625 | $625 | May 9, 2024 |
| May 19, 2017 | 32087040H | RESOLVE | CLASS - 2 | B254,48B,19A. FOR SLANT FIN MODEL #L70CZ DUAL. AS PER CLASS 2 (B25428-301.1 19A-MANUAL RESET PRESSURE CONTROL IN WRON... | $0 | $0 | Jul 20, 2017 |
| May 19, 2017 | 32087043N | RESOLVE | CLASS - 2 | B254,48B,19A. FOR SLANT FIN MODEL #L70CZ DUAL. AS PER CLASS 2 (B25428-301.1 FAILURE TO MAINTAIN. 19A-MANUAL RESET PRE... | $0 | $0 | Jul 20, 2017 |
| May 19, 2017 | 32087041J | RESOLVE | CLASS - 2 | B254,48B,19A. FOR SLANT FIN MODEL #L70CZ DUAL. AS PER CLASS 2 (B25428-301.1, 19A-MANUAL RESET PRESSURE CONTROL IN WRO... | $0 | $0 | Jul 20, 2017 |
| May 19, 2017 | 32087036P | RESOLVE | CLASS - 1 | 5A,B154,19A,48B. FOR SLANT FIN MODEL #L70CZ DUAL-BOILER MISSING PARTSHAZARDOUS CONDITION; 51-CEASE USE MISSING GAUGE ... | $0 | $0 | Jul 20, 2017 |
| May 19, 2017 | 32087037R | RESOLVE | CLASS - 1 | 51 FOR SLANT FIN MOEL #L70 LZ DUAL. BOILER MISSING PARTS HAZARDOUS CONDITIONS. 51-CEASE USE AND MISSING TRANSFORMER; ... | $0 | $0 | Jul 20, 2017 |
| May 19, 2017 | 32087038Z | RESOLVE | CLASS - 1 | 51 EVO MODEL #HWD 00299 WATER HEATER. BACK FIRING. HAZARDOUS CONDITION. | $0 | $0 | Aug 17, 2017 |
| May 19, 2017 | 32087039K | RESOLVE | CLASS - 2 | B243,48C,19A. FOR SLANT FIN MODEL #L70CZ DUAL. AS PER CLASS 2 (B25428-301.1 FAILURE TO MAINTAIN. 19A-MANUAL RESET PRE... | $0 | $0 | Jul 20, 2017 |