Issued Violation Type Category Description Disposed
Oct 2, 2024 00013 AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE V-DOB VIOLATION - ACTIVE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
Jul 7, 2023 17722 IMEGNCY-IMMEDIATE EMERGENCY ANYTHINGOPTIONAL V*-DOB VIOLATION - DISMISSED PROVIDE SIDEWALK SHED AT EXPOSURE #1 NORTH ELEVATION (APPROXIMATELY) 55 LINEAR FEET) Jul 20, 2023
Jul 5, 2023 FEU10703ZT C-CONSTRUCTION OTHER OPTIONAL V-DOB VIOLATION - ACTIVE ADDITIONAL INFO.EXP4 HAD A GAP TOWARDS THE ROOF ADJACENT TO NEIGHBOR BLDG.BLDG APPEARD TO BE LEANING TOWARDS EXP2.ON ...
Jun 7, 2023 FEU10702ZT C-CONSTRUCTION OTHER OPTIONAL V-DOB VIOLATION - ACTIVE FTM.1.THE FACADE ON EXP1 HAD SEVERELY DETERIORATED.SOME BROWNSTONE FACADE APPEARD TO BE LOOSE.THE WNDW LINTEL&SILL HA...
Jun 7, 2023 FEU10701ZT C-CONSTRUCTION OTHER OPTIONAL V-DOB VIOLATION - ACTIVE ADDITIONAL INFO.EXP4 HAD A GAP TOWARDS THE ROOF ADJACENT TO NEIGHBOR BLDG.BLDG APPEARED TO BE LEANING TOWARDS EXP2.ON...
Apr 18, 2023 LL0701GM C-CONSTRUCTION OTHER OPTIONAL V-DOB VIOLATION - ACTIVE EMERGENCY WORK ORDER DUE TO DEFECTIVE FACADE.AT EXPOSURE#1(NORTH EL) OBSERVED CRACKED/SPALLING/CRACK STUCCO IN SEVERA...
Apr 18, 2023 LL0702GM C-CONSTRUCTION OTHER OPTIONAL V-DOB VIOLATION - ACTIVE FAILURE TO MAINTAIN BLDG-THE BUILDING STRUCTURE IS LEANINGOUT OF PLUMB TOWARDS EXP2.GAP SEPARATION OBSERVED BETWEEN 1...
Dec 1, 2022 22-04286 C-CONSTRUCTION OTHER OPTIONAL V-DOB VIOLATION - ACTIVE PREMISES 5-STORY SEMI-ATTACHED MASONRY BUILDING. BUILDING SETTLED APPROXIMATELY 10" ON TOP WHERE AS BOTTOM 0" GAP, UN...
Mar 2, 2022 00075 AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE V-DOB VIOLATION - ACTIVE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
Jan 5, 2022 00047 AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE V-DOB VIOLATION - ACTIVE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
Nov 10, 2021 00059 AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE V-DOB VIOLATION - ACTIVE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
Sep 14, 2015 FEU10701DEH C-CONSTRUCTION OTHER OPTIONAL V-DOB VIOLATION - ACTIVE FAILURE TO COMPLY WITH COMMISSIONER'S ORDER TO HIRE A PROFESSIONAL SUR VEY TEAM TO PERFORM REGULAR MONITORING OF BUIL...
Apr 8, 2015 00049 AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE V*-DOB VIOLATION - DISMISSED FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION Jul 31, 2015
Jan 15, 2015 FEU10701DEH C-CONSTRUCTION OTHER OPTIONAL V-DOB VIOLATION - ACTIVE FAILURE TO MAINTAIN,5STORY O.L.T. BUILT 1900 BLDG DEFLECTS EAST.OWNER TO HIRE PROFRESSIONAL SURVEY TEAM TO PERFORM RE...
Jun 17, 2014 FEU10701DEH C-CONSTRUCTION OTHER OPTIONAL V*-DOB VIOLATION - DISMISSED FAIL TO MAINTAIN: 5 STORY OLD LAW TENEMENT CA. 1900. DEFLECTING EAST REMEDY: OWNER TO HIRE NYS PE TO PERFORM FULL STR... Feb 11, 2015
Jun 17, 2014 FEU10701DCH C-CONSTRUCTION OTHER OPTIONAL V*-DOB VIOLATION - DISMISSED FAILURE TO MAINTAIN Jul 29, 2014
Feb 10, 2009 09-0896 LANDMK-LANDMARK NONE V*-DOB VIOLATION - DISMISSED May 1, 2024
Jan 3, 2008 06003 LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED V*-DOB VIOLATION - DISMISSED Mar 26, 2013
Feb 13, 2004 06852 LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED V*-DOB VIOLATION - DISMISSED Mar 26, 2013
Mar 19, 2003 03536 LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED V*-DOB VIOLATION - DISMISSED Mar 26, 2013
Sep 16, 1997 178816 LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED V*-DOB VIOLATION - DISMISSED Mar 26, 2013
Aug 18, 1997 07A04 C-CONSTRUCTION OTHER OPTIONAL V*-DOB VIOLATION - DISMISSED Jun 14, 1999
Aug 18, 1997 07A04 C-CONSTRUCTION OTHER OPTIONAL VP-VIOLATION UNSERVED ECB-ACTIVE
Feb 10, 1997 05105 LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED V*-DOB VIOLATION - DISMISSED Mar 26, 2013
Sep 1, 1994 06405 LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED V*-DOB VIOLATION - DISMISSED Apr 24, 1995