ECB violations

106 West 83 Street, Manhattan • Block 01213 • Lot 0038

31 records

Environmental Control Board violations, which carry a hearing and a penalty.

Issued Violation Status Severity Description Penalty Balance due Hearing
Jan 20, 2026 39174428Y ACTIVE CLASS - 2 FAILURE TO SUBMIT CERTIFICATE OF CORRECTION FOR VIOLATION #39154033L ISSUED ON 07/17/2025 FOR WORK WITHOUT A PERMIT(M... $1,250 $1,250 Oct 15, 2026
Jul 17, 2025 39154033L RESOLVE CLASS - 1 METAL STRUCTURE AT REAR OF ABOVE BUILDING BUILT ON LOTLINE APPROX 30' X15' AND 20' HIGH;NO PERMIT ON FILE FOR THIS WO... $1,250 $1,250 Apr 2, 2026
Oct 17, 2023 39097230M RESOLVE CLASS - 2 AS PER ONE ROCKMILLS MP-40. STEAM HEATING BOILER; NO PRV ON PIPING FOR DOMESTIC HOT WATER COIL-THERMOMETER FOR DOMEST... $312 $312 Jan 2, 2025
Sep 22, 2021 39047891Y RESOLVE CLASS - 2 CORRODED PIPE TO BOILER LEFT SIDE/GAS PIOLIT REGULATOR AND TUBING INCORRECT/COLD WATER THERMO LOOP MISSING FROM HW MI... $0 $0 Nov 18, 2021
Oct 15, 2019 39011246R RESOLVE CLASS - 1 I OBSERVED IN THE BASEMENT AT THE THE ELECTRICAL SERVICE EQUIPMENT THE SERVICE ENTRANCE CONDUCTORS INSTALLED IN A HOL... $0 $0 Mar 12, 2020
Oct 15, 2019 39011245P RESOLVE CLASS - 1 I OBSERVED INSIDE THE 100 AMP SERVICE SWITCH THE NEUTRAL NOT BONDED TO THE ENCLOSURE (MISSING MAIN BONDING JUMPER) VI... $1,500 $0 Mar 12, 2020
Oct 15, 2019 39011244N RESOLVE CLASS - 2 I OBSERVED OUTSIDE UNDERNEATH THE FRONT STAIRS AT THE UTILITY ENDLINE BOX THE USE OF EMT PIPE AS A SERVICE RACEWAY IN... $800 $0 Mar 12, 2020
Jan 14, 2019 35390713Y RESOLVE CLASS - 2 FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION #35372491Z ISSUED ON 11/19/18 AND TO FI... $1,250 $0 May 23, 2019
Nov 19, 2018 35372491Z RESOLVE CLASS - 1 OCCUPANCY CONTRARY TO THAT ALLOWED BY THE CERTIFICATE OF OCCUPANCY OR BUILDINGS DEPT RECORDS NOTED: COFO #121840259 I... $6,250 $0 May 23, 2019
Oct 1, 2018 35361390X RESOLVE CLASS - 1 OCCUPANCY CONTRARY TO THAT ALLOWED BY THE CERTIFICATE OF OCCUPANCY OR BUILDING DEPARTMENT RECORDS. C OF O #121840259 ... $2,500 $0 Mar 21, 2019
Oct 1, 2018 35361389Z RESOLVE CLASS - 2 FAILURE TO MAINTAIN BUILDING WALL(S) OR APPURTENANCES. NOTED: AT EXP# 2, 3 AND 4. AT PARAPET WALLS MORTAR CRACKED AND... $1,250 $0 Jan 17, 2019
Jul 17, 2018 32097272X RESOLVE CLASS - 2 B254,50A,50B,50C,50D,50E,50F,50G,50H. AS PER CLASS 2 (B254) 28.301.1 FAILURE TO MAINTAIN 50A-FLUE PIPING NOT SUPPORTE... $625 $0 Nov 1, 2018
May 1, 2018 32096378J RESOLVE CLASS - 2 B254:5B,6,15,32A:AS PER CLASS 2 B254 28-301.1.VIOLATING CONDITIONS:MISSING DISCHARGE PIPE;MISSING DOMESTIC RELIEF VAL... $625 $0 Aug 23, 2018
Mar 13, 2018 35324826P RESOLVE CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.OBSERVED ON 03/13/18 AT ABOVE ADDRESS IMPORPER VENTILATION USED... $312 $0 Nov 1, 2018
Feb 16, 2018 35284107P RESOLVE CLASS - 2 FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATION #35311452R ISSUED 01/10/18 AND TO FILE... $400 $0 Jun 14, 2018
Jan 10, 2018 35311452R RESOLVE CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. AT BASEMENT LEVEL, THE TWO SEPARATE GAS METER ROOMS, DO NOT HA... $1,000 $0 May 10, 2018
Dec 12, 2017 35274340M RESOLVE CLASS - 1 AN UNLAWFUL ACT. FAILURE TO COMPLY W/AN ORDER OF THE COMMISSIONER. FAILURE TO CORRECT & CERTIFY ECB#35290398P ISSUED ... $2,400 $0 Apr 19, 2018
Nov 24, 2017 35297608X RESOLVE CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.NOTED: AT TIME OF INSPECTION THERE WERE NO FRESH AIR VENTS TO E... $2,500 $0 Jun 21, 2018
Oct 13, 2017 35294475H RESOLVE CLASS - 1 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. AT TIME OF INSPECTION NEITHER OF THE 2 GAS METER ROOMS IN CELLAR,H... $1,000 $0 May 10, 2018
Sep 6, 2017 35290366K RESOLVE CLASS - 3 OCCUPANCY CONTRARY TO THAT ALLOWED BY THE C OF O OR BLDG DEPT RECORDS.TCO#121840259 INDICATES 1ST STY AS 9 SRO ROOMS,... $500 $0 Mar 29, 2018
Sep 6, 2017 35290398P RESOLVE CLASS - 1 FAILURE TO GROUND ELECTRICAL SYSTEMS. OBSERVED CONDUCT W/GROUNDING CONDUCTOR BROKEN & LAYING ON FLOOR OF SPRINKLER CO... $4,800 $0 Mar 29, 2018
Sep 6, 2017 35290545X RESOLVE CLASS - 1 FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER.OBSERVED ON 09/06/2017 @ABOVE ADDRESS IN CELLAR NO FRESH AIR IN TAK... $1,000 $0 Mar 29, 2018
Sep 6, 2017 35290397N RESOLVE CLASS - 2 ELECTRICAL WORK W/O A PERMIT. NO ELECTRICAL APPLICATION ON FILE FOR ANY EXISTING OF NEW WORK PERTAINING TI ELECTRICAL... $800 $0 Mar 29, 2018
Feb 24, 2016 35171555H RESOLVE CLASS - 3 OCCUPANCY CONTRARY TO THAT ALLOWED BY THE C OF O OR BLDG DEPT RECORDS.C OF O #121840259T003 INDICATES 1ST FL TO BE 9 ... $400 $0 Apr 14, 2016
Feb 24, 2016 35171556J RESOLVE CLASS - 2 EXIT DOOR NOT SELF CLOSING. THE FOLLOWING DOORS NOT SELF CLOSING: 3RD FL WEST SIDE EXIT DOOR,2ND FL WEST & EAST DOORS... $0 $0 Apr 14, 2016
Jan 23, 2014 35034184R RESOLVE CLASS - 1 SEC. 715. FAILURE TO COMPLY W/OPENING PROTECTIVES. NOTED: EXIT DOORS LEADING TO STAIRCASE ARE LOCKED IN OPEN POSITION... $400 $0 Sep 18, 2014
Jan 23, 2014 35034182N RESOLVE CLASS - 1 OCCUPANCY CONTRARY TO THAT ALLOWED BY C/O #94927 ILLEGAL OCCUPANCY NOTED: 1)CELLAR OCCUPIED AS A CAFETERIA & OFFICES.... $1,200 $0 Sep 18, 2014
Jan 23, 2014 35034183P RESOLVE CLASS - 2 WORK W/O PERMIT. WORK NOTED: CREATE CONCIERGE DECK & GLASS LOBBY ENTRANCE. REMEDY: STOP ALL WORK. OBTAIN PERMIT. $800 $0 Sep 18, 2014
Jan 15, 2003 34372786J RESOLVE Non-Hazardous WORK WITHOUT PERMITK WORK NOTED GUT DEMO NOTED THROUGHOUT BLDF FROM 1 FLOOR THRU 5 FL GUT DEMO APPROX 40% COMPLETED N... $0 $0 Mar 4, 2004
Jan 12, 2000 34155342H RESOLVE Non-Hazardous WORK WITHOUT A PERMIT.WORK NOTED PARTITION WALL REMOVED BETWEEN ROOMS 5F AND 5E AT 5 STORY REAR SECTION.STOP ALL WORK... $2,500 $0 Mar 16, 2000
Aug 3, 1988 34011206K RESOLVE Non-Hazardous OCCUPANCY CONTRARY TO THAT ALLOWED BY THE C OF O. REMEDY: FILE PLANS TO OBTAIN APPROVALS. $250 $0 Feb 2, 1989