ECB violations
105-113 West 86 Street, Manhattan • Block 01217 • Lot 0029
15 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Apr 14, 2026 | 39553033J | RESOLVE | CLASS - 2 | 16 STORY ALT2 FACADE WORK ACTIVE SITE.OBSERVED C HOOKS INSTALLED ON PARAPET WALL WITH WIRE ROPES CONNECTED TO PLATFOR... | $1,250 | $1,250 | Aug 13, 2026 |
| Apr 14, 2026 | 39553034L | RESOLVE | CLASS - 1 | 16 STORY ALT2 FACADE WORK ACTIVE SITE.OBSERVED SUSPENDED SCAFFOLDS IN PLACE/USE AT EXP#1.UPON INSPECTION OF OUTRIGGER... | $2,500 | $2,500 | Aug 13, 2026 |
| Apr 14, 2026 | 39553036P | RESOLVE | CLASS - 1 | 16 STORY ALT2 FACADE ACTIVE SITE.OBSERVED SIDEWALK SHED PERMIT#M01189887INSTALLED/MAINTAINED CONTRARY TO PLANS.OBSERV... | $2,500 | $2,500 | Aug 13, 2026 |
| Apr 14, 2026 | 39553035N | RESOLVE | CLASS - 2 | 16 STORY ALT2 FACADE WORK ACTIVE SITE.OBSERVED C HOOKS INSTALLED/IN PLACE ON PARAPET WALLS WITH WIRE ROPES ATTACHED T... | $800 | $800 | Aug 13, 2026 |
| Apr 14, 2026 | 39553032H | RESOLVE | CLASS - 1 | 16 STORY ALT2 FACADE WORK ACTIVE SITE. SUSPENDED SCAFFOLDS/EQUIPMENT INSTALLED/PARAPET CLAMPS AT EXP#2. 6 FT ABOVE AD... | $2,500 | $2,500 | Aug 13, 2026 |
| May 7, 2015 | 35131939K | RESOLVE | CLASS - 1 | SEC. 3310.4 PSWO: ISSUED& POSTED AT MAIN ENTRANCE(STOP ALL SCAFFOLD WORK)FAILURE TO CONFORM TO THE SITE SAFETY PROGRA... | $1,600 | $0 | Jun 25, 2015 |
| Feb 27, 2013 | 34932465L | RESOLVE | CLASS - 2 | MISCELLANEOUS VIOLATIONS,FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.IMPROPER LOCATION OF GAS METER.OBSERVE... | $800 | $0 | Apr 18, 2013 |
| Feb 7, 2013 | 34989645X | RESOLVE | CLASS - 2 | FAILED TO NOTIFY DEPT/OBTAIN PERMIT PRIOR TO USE/INST OFF OUTRIGGER BEAMS IN CONNECTION W/SUSPENDED SCAFFOLD -2 SETS ... | $400 | $0 | Mar 28, 2013 |
| Aug 31, 2007 | 34593546J | RESOLVE | Non-Hazardous | FAILURE TO CARRY OUT DEMOLITION OPERATIONS IN A SAFE AND PROPER MANNERDEFECT NOTED: CEILING OF APT #16C PENETRATED DU... | $0 | $0 | Oct 25, 2007 |
| Mar 28, 2006 | 38158222M | RESOLVE | Non-Hazardous | 55H10/21M07. 55- HOIST MACHINE BEARING WORN REPAIR. 21- INTERLOCK COVERS MISSING PROVIDE. | $180 | $0 | May 18, 2006 |
| May 13, 2005 | 38152975J | RESOLVE | Non-Hazardous | 69I10 69) CAR (SPRING) BUFFER IS DAMAGED AND TILTED. | $0 | $0 | Jun 30, 2005 |
| May 11, 2005 | 38152573R | RESOLVE | Non-Hazardous | 12Q03/59Q03/71Q03/66Z09/-(12)IN CAR LIGHTING IS UNGUARDED.(59)MACH.RM LIGHTING IS UNGUARDED.(71)LIGHTING(WORK LIGHTS)... | $0 | $0 | Jun 30, 2005 |
| Jun 27, 2001 | 34274512N | RESOLVE | Hazardous | FAILURE TO MAINTAIN PLUMBING AND/OR APPORTENANCES-HAZARDOUS. REMEDY:MAINTAIN PLUMBING AND/OR APPORTENANCES LOCATION:T... | $800 | $0 | Oct 25, 2001 |
| Jan 19, 1999 | 38083702H | RESOLVE | Non-Hazardous | 40U, PERFORM 5 YEAR TEST, PROPERTY TAG DEVICE AND FILE FORM. | $2,500 | $0 | Mar 25, 1999 |
| Jan 19, 1999 | 38083701X | RESOLVE | Non-Hazardous | 60J,63J,73O. PROVIDE PROPER CLEARANCE BETWEEN COUNTER WEIGHT AND BUFFER, ADJUST TENSION ON GOVERNOR SHEAVE, CLEAN INS... | $2,500 | $0 | Mar 25, 1999 |