ECB violations
720 West End Avenue • Block 01243 • Lot 0001
46 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Nov 18, 2024 | 39534469R | RESOLVE | CLASS - 2 | 16 STORY ALTERATION ACTIVE SITE.OBSERVED ACTIVE WORK ON SUSPENDED SCAFFOLDS FIXED OUTRIGGER BEAMS TIEBACKS TO CONCRET... | $250 | $0 | Jan 23, 2025 |
| Nov 18, 2024 | 39534470Y | RESOLVE | CLASS - 2 | 16 STORY ALTERATION ACTIVE SITE.OBSERVED ACTIVE WORK ON SUSPENDED SCAFFOLDS FIXED OUTRIGGER BEAMS TIEBACKS TO CONCRET... | $0 | $0 | Jan 23, 2025 |
| Mar 1, 2024 | 39526044L | RESOLVE | CLASS - 2 | SUPPORTEDSCAFFOLD EXP1 TARP ENCLOSURE AND METAL HOOKS NYLON STRAP AS PART OF TIE DOWN OF TARP,REVIEW APPROVED SF DRAW... | $1,250 | $0 | May 9, 2024 |
| Feb 20, 2024 | 39525697Y | RESOLVE | CLASS - 2 | 3314.1)AT TIME OF INSPECTION RESPOND TO AN COMPLAINT WHERE A WORKER FELL TRUE THE OPEN PLATFORM FROM THE PIPE SCAFFOL... | $2,500 | $0 | Feb 13, 2025 |
| Feb 15, 2024 | 39525642R | RESOLVE | CLASS - 1 | AT TIME OF INSPECTION OF PROPOSED 16 STORY ALTERATION I OBSERVED STAIRS IN USE BY WORKERS FROM THE CELLAR LEVEL TO TH... | $2,500 | $0 | Feb 13, 2025 |
| Jan 30, 2024 | 35680352N | RESOLVE | CLASS - 2 | SIGN PRINTED ON NETTING FOR SCAFFOLDING AT FRONT FACADE OF BUILDING ISOVER 20 FEET ABOVE THE CURB LEVEL IN A RESIDENT... | $1,250 | $0 | Apr 18, 2024 |
| Jan 30, 2024 | 35680351L | RESOLVE | CLASS - 2 | SIGN PRINTED ON NETTING FOR SCAFFOLDING AT FRONT FACADE OF BUILDING ONDISPLAY WITHOUT A PERMIT.(720 WESTEND.COM)REM:R... | $625 | $0 | Apr 18, 2024 |
| Jan 30, 2024 | 35680354R | RESOLVE | CLASS - 2 | UNLAWFUL SIGN ON A PROTECTIVE STRUCTURE(SIGN IS PRINTED ON THE NETTINGFOR SCAFFOLDING AT FRONT FACADE OF BUILDING).(7... | $2,500 | $0 | Apr 18, 2024 |
| Jan 30, 2024 | 35680353P | RESOLVE | CLASS - 2 | IDENTIFICATION SIGN PRINTED ON NETTING FOR SCAFFOLDING AT FRONT FACADEOF BUILDING EXCEED MAXIMIUM ALLOWABLE SIZE OF 1... | $1,250 | $0 | Apr 18, 2024 |
| Dec 18, 2023 | 39524204M | RESOLVE | CLASS - 1 | PERMIT HOLDER FAILED TO ENSURE WORKERS USING A FRAME LADDER AS PER MANUFACTURER SPECIFICATIONS. I OBSERVED WORKER ON ... | $2,500 | $0 | Feb 22, 2024 |
| Oct 20, 2023 | 39522771J | RESOLVE | CLASS - 1 | EXISTING 15 STORY BUILDING CURRENTLY UNDER ALTERATION, DURING INSPECTION I OBSERVED IN MULTIPLE LOCATIONS AT FLOOR LE... | $2,500 | $0 | Sep 26, 2024 |
| Oct 20, 2023 | 39522770H | RESOLVE | CLASS - 2 | PROPOSED 15 STORIES BUILDING CURRENTLY UNDER ALTERATION, I OBSERVED INMULTIPLE LOCATIONS AT WINDOWS & FLOOR LEVELS AN... | $0 | $0 | Dec 28, 2023 |
| Oct 20, 2023 | 39522767R | RESOLVE | CLASS - 1 | EXISTING 15 STORIES BUILDING CURRENTLY UNDER ALTERATION . I OBSERVED ON 15TH FLOOR WORKING LEVEL WITH CHANGES IN ELEV... | $0 | $0 | Sep 26, 2024 |
| Jul 22, 2023 | 39520303J | RESOLVE | CLASS - 1 | A WORKER FELL IN DEBRIS CONTAINER WHILE DUMPING DEBRIS. PERMIT HOLDER JOB#123580062 FAILED TO SUBMIT REPORT WITHIN 3 ... | $2,500 | $0 | Apr 18, 2024 |
| Jul 18, 2023 | 39519414Y | RESOLVE | CLASS - 1 | AT TIME OF INSPECTION RESPOND TO AN INCIDENT WHERE A WORKER FELL INTO A GARBAGE CONTAINER USING A WHEEL BARREL TO DUM... | $2,500 | $0 | Jan 9, 2025 |
| May 22, 2023 | 39516912N | RESOLVE | CLASS - 2 | OBSERVED SUPPORTED SCAFFOLDING SURROUNDING THE BUILDING AT EXP.# 1 & 4 WHICH WERE ERECTED ON TOP OF THE SIDEWALK SHED... | $0 | $0 | Jul 27, 2023 |
| May 22, 2023 | 39516913P | RESOLVE | CLASS - 2 | OBSERVED SIDEWALK SHED IN PLACE AT EXP.#1&4, UPON REVIEWING THE APP. DOCUMENTS,SWS @ EXP.#1 HAD 1 EXTRA BAY WITH SPAC... | $0 | $0 | Jul 27, 2023 |
| Jul 21, 2022 | 35646592N | RESOLVE | CLASS - 1 | FAILURE TO NOTIFY DEPT OF INCIDENT THAT RESULTED IN FATALITY OR INJURYNOTE:WORKER HIT ON HEAD BY FALLING PIPE TAKEN T... | $5,000 | $0 | Mar 2, 2023 |
| Jun 23, 2022 | 39502622H | RESOLVE | CLASS - 1 | OBSERVED IN SUB CELLAR LARGE AMOUNT OF WATER AND OIL MIXTURE ALONG WITH LARGE AMOUNTS OF METAL AND STEEL CUT. BOTH CO... | $2,500 | $0 | Jan 19, 2023 |
| Jun 23, 2022 | 39502621X | RESOLVE | CLASS - 1 | OBSERVED IN SUB CELLAR WHERE PIPE FELL FROM CEILING THAT WAS NOT PROPERLY SECURED OR REMOVED AFTER IT BEING CUT HITTI... | $0 | $0 | Jan 19, 2023 |
| Mar 18, 2022 | 35645895X | RESOLVE | CLASS - 1 | FAILURE TO DESIGNATE&HAVE SITE SAFETY MANAGER PRESENT@SITE AS REQUIRED.INSP OF 15STYALTBG,WORK IN PROGRESS.OBSERVED N... | $0 | $0 | Sep 8, 2022 |
| Mar 18, 2022 | 39058327R | RESOLVE | CLASS - 2 | WORK DOES NOT CONFORM TO APPROVED CONST DOCS OR APPROVED AMENDMENTS. NOTED FULL INTERIOR DEMO OF 16 STORY BUILDING. O... | $625 | $0 | Sep 1, 2022 |
| Mar 18, 2022 | 35645894Y | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN/DISPLAY ONSITE DOCS REQUIRED BY BCCH33.INSP OF 15STYALTB,WORK IN PROGRESS&UP OF MY REQUEST TO REV... | $0 | $0 | Sep 8, 2022 |
| Mar 18, 2022 | 35645893M | RESOLVE | CLASS - 1 | FAILURE TO PERFORM SUCCESSFUL HYDROSTATIC PRESSURE TEST OF STANDPIPE SYSTEM.INSP OF 15STYALTB,WORK IN PROGRESS.UPON M... | $0 | $0 | Sep 8, 2022 |
| Jul 10, 2019 | 35368991N | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE AND APPURTENANCES AS NOTED EXPOSURE 1 INADEQUATELY SUPPORTED A/C EXP3 SP... | $625 | $0 | Dec 5, 2019 |
| Dec 17, 2018 | 37013849M | RESOLVE | CLASS - 2 | FAILURE TO COMPLY WITH COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATION #35250252X ISSUED ON 3/9/18,& TO FILE A CE... | $1,250 | $0 | Jun 20, 2019 |
| Apr 12, 2018 | 35323757X | RESOLVE | CLASS - 2 | FAILURE TO NOTIFY DEPT OF INSTALLATION OF SUSPENDED SCAFFOLD. NOTE AT TIME OF INSPECTION I OBSERVED SUSPENDED SCAFFOL... | $1,250 | $0 | Aug 2, 2018 |
| Mar 9, 2018 | 35250252X | RESOLVE | CLASS - 2 | OCCUPANCY CONTRARY TO THAT ALLOWED BY THE C OF O OR BLDG DEPT RECORDS.NOTED: AT TIME OF INSPECTION OBSERVED APT#210 O... | $1,250 | $0 | Apr 26, 2018 |
| Sep 25, 2017 | 35284984R | RESOLVE | CLASS - 1 | ELECTRICAL WORK W/O A PERMIT. BASEMENT FIRE ALARM SERVICE DISCONNECT/ SERVICE ENTRANCE CONDUCTOR, 60 AMP DISCONNECT, ... | $800 | $0 | Nov 9, 2017 |
| Jun 27, 2014 | 35096287N | RESOLVE | CLASS - 1 | PERM DWELLING USED/CONVERTED FOR OTHER THAN PERMANENT RESIDENTIAL PURPOSES.C/O #75-633 INDICATES BLDG TO BE LEGALLY A... | $3,200 | $0 | Aug 21, 2014 |
| Jan 27, 2014 | 35024140X | RESOLVE | CLASS - 2 | REMOVAL OF SHED OR PROTECTIVE MEASURE WITHOUT DEPARTMENT APPROVAL. REM:OBTAIN APPROVAL FROM DOB BEFORE PROTECTIVE MEA... | $400 | $0 | Mar 13, 2014 |
| Mar 6, 2012 | 38220941N | RESOLVE | CLASS - 2 | 67L10,05E01,05M07,45E01,29Q03: 67L;REPAIR. 05E;CLUTCH SCRAPING. 05MZONE LOCK RESTRICTOR. 45E;ROPE RUBBING. 29Q;EXPOSE... | $0 | $0 | Apr 26, 2012 |
| Jul 29, 2011 | 36016470P | RESOLVE | CLASS - 2 | FAILURE TO FILE AN AMENDED 6TH ROUND REPORT ACCEPTABLE TO THIS DEPT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRI... | $0 | $0 | Nov 3, 2011 |
| Jun 10, 2011 | 32070812H | ACTIVE | CLASS - 2 | B254/15/21A/50A/50C/50E/B254/16/32A/50B/50D/50A-REMOVE OPEN CONTAINERSOF FUEL OIL/50B-REMOVE ALL STORAGE/50C-LEAKING ... | $500 | $0 | Jul 28, 2011 |
| Jun 11, 2010 | 36013510R | RESOLVE | CLASS - 2 | FAILURE TO FILE AN AMENDED SIXTH ROUND REPORT ACCEPTABLE TO THIS DEPT INDICATING CORRECTION OF UNSAFE CONDITIONS DESC... | $0 | $0 | Dec 2, 2010 |
| Apr 15, 2009 | 34764748L | RESOLVE | CLASS - 2 | SEC. 28-105.11. THE BLDG PERMIT OR COPY SHALL BE POSTED IN CONSPICUOUSPLACE AT THE WORK SITE VISIBLE TO THE PUBLIC. N... | $4,000 | $0 | Jun 4, 2009 |
| Apr 15, 2009 | 34764747J | RESOLVE | CLASS - 2 | FAILURE TO PROVIDE REQUIRED SIGNAGE AND INFORMATION ON SIDEWALK SHED. NOTED: WRONG EXPIRATION DATE ON SIDEWALK SHED S... | $0 | $0 | Jun 4, 2009 |
| Jul 15, 2008 | 34684721L | RESOLVE | CLASS - 2 | FAILURE TO PROVIDE APPROVED/ACCEPTED PLANS AT JOB SITE AT TIME OF INSPNO P.E DRAWING FOR SUPPORT COLUMNS INSIDE GREEN... | $2,500 | $0 | May 13, 2010 |
| Jul 15, 2008 | 34684722N | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD ALL PERSONS AND PROP AFFECTED BY CONST OPERATIONSREMEDY: SAFEGUARD PUBLIC & PROPERTY. | $12,000 | $0 | May 13, 2010 |
| Jul 15, 2008 | 34684720J | RESOLVE | CLASS - 1 | SEC BC 3314.6 MISC VIOL: THE FOOTING AND ANCHORAGE FOR EVERY SCAFFOLD SHALL BE SOUND & RIGID. (3) THREE SECTION OF PI... | $8,000 | $0 | May 13, 2010 |
| Jul 15, 2008 | 34684719M | RESOLVE | CLASS - 1 | LICENSED RIGGER FAILED TO ENSURE SCAFFOLD WORKER MET MINIMUM REQ NO CERTIFICATION OF FITNESS. | $8,000 | $0 | May 13, 2010 |
| Jul 15, 2008 | 34684718K | RESOLVE | CLASS - 2 | WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS/AMENDMENTS OUTRIGGER BEAM DID NOT CONFORM TO APPROVED PLANS/... | $2,500 | $0 | May 13, 2010 |
| Sep 5, 2002 | 34335501Y | RESOLVE | Hazardous | FAILURE TO FILE AN AMENDEDTOUND FIVE REPORT ACCEPTABLE TO THIS DEPARMTNENT PURSUANT TO RULE R.C.N.Y 32-03B(5), INDICA... | $1,000 | $0 | Nov 7, 2002 |
| Jul 5, 2002 | 34314957J | RESOLVE | Hazardous | FAILURE TO FILE AN AMENDED ROUND FIVE REPORT ACCEPTABLE TO THIS DEPARTMENT PURSUANT TO RULE R.C.N.Y. 32-03B (5), INDI... | $1,000 | $0 | Nov 7, 2002 |
| May 3, 2002 | 34314535J | RESOLVE | Hazardous | FAILURE TO FILE AN AMENDED ROUND FIVE REPORT ACCEPTABLE TO THIS DEPARTMENT PURSUANT TO RULE R.C.N.Y. 32-03B(5), INDIC... | $400 | $0 | Jul 25, 2002 |
| Feb 8, 2002 | 38121108J | RESOLVE | Non-Hazardous | 3I12/ 5I12/ 28H12/ 31D6/ 57O2/ (3) CAR FLOOR WORN OUT, DAMAGED REPLACE (5) CAR GATE DOOR DAMAGED (28) WORN GUIDE SHOE... | $180 | $0 | Mar 28, 2002 |