ECB violations
301 West 83 Street, Manhattan • Block 01245 • Lot 0070
28 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Jan 14, 2026 | 39173910H | RESOLVE | CLASS - 2 | FAILURE TO SUBMIT CERTIFICATE OF CORRECTION FOR VIOLATION #39152230L ISSUED ON 06/27/2025 FOR FAILURE TO MAINTAIN BUI... | $625 | $0 | Mar 26, 2026 |
| Jan 14, 2026 | 39174921H | ACTIVE | CLASS - 2 | FAILURE TO SUBMIT CERTIFICATE OF CORRECTION FOR VIOLATION #39152231N ISSUED ON 06/27/2025 FOR FAILURE TO MAINTAIN BUI... | $625 | $0 | May 7, 2026 |
| Jun 27, 2025 | 39152231N | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: NO FIRE STOPPING PER BC 712.3 (2014 CODE); 27-345; BC 711.2.4 ... | $2,530 | $0 | Sep 4, 2025 |
| Jun 27, 2025 | 39152230L | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: USE OF PROHIBITED DOOR AND/OR HARDWARE PER BC 1008.1.8 (2014 C... | $2,530 | $0 | Sep 4, 2025 |
| Jun 23, 2025 | 39151711H | RESOLVE | CLASS - 2 | CLASS 2 ITEMS: ADJUST CAR DOOR TO BE FULLY OPEN. PROVIDE BRAILLE NUMBERED FLOOR SIGNS ON ALL LANDINGS AS NEEDED. PROV... | $0 | $0 | Aug 28, 2025 |
| Dec 20, 2022 | 39076004L | RESOLVE | CLASS - 2 | FUEL OIL PUMP BELT GUARD MISSING-NO DISCHARGE PIPE FOR PRV ON DOMESTIC HW COIL PIPING-SAFETY VALVE DISCHARGE PIPES NO... | $655 | $0 | Feb 23, 2023 |
| Apr 12, 2022 | 35651052Z | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING WALL(S)OR APPURTENANCES OBSERVED:AT CELLAR LEVEL,WATER PENETRATIONS THROUGH THE FOUNDATI... | $3,125 | $0 | Jul 14, 2022 |
| Apr 12, 2022 | 35651051R | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER OBSERVED:AT EXPOSURE#2,RETAINING WALL,BOILER ROOM EMERGENCY EXI... | $1,562 | $0 | Jul 14, 2022 |
| Nov 27, 2019 | 35360027R | RESOLVE | CLASS - 1 | UNLAWFUL ACTS.FAILURE TO COMPLY WITH AN ORDER OF THE COMMISSIONER.IN SEPTEMBER 6,2019,TWO ELECTRICAL VIOLATIONS WAS I... | $2,500 | $0 | Jul 20, 2020 |
| Oct 16, 2019 | 35359978Y | RESOLVE | CLASS - 1 | UNLAWFUL ACTS.FAILURE TO COMPLY W/AN ORDER OF THE COMMISSIONER.IN SEPT06,2019 TWO ELECTRICAL VIOLATION WAS ISSUED TO ... | $2,500 | $0 | Oct 29, 2020 |
| Sep 6, 2019 | 39009026M | RESOLVE | CLASS - 1 | I OBSERVED THE INSTALLATION OF FLEXIBLE RUBBER COATED CABLE FROM THE BASEMENT TO THE ROOF WITHOUT THE PROPER SUPPORT ... | $1,600 | $0 | Jun 18, 2020 |
| Sep 6, 2019 | 39009025K | RESOLVE | CLASS - 2 | I OBSERVED ON THE ROOFTOP THE INSTALLATION OF A TEMPORARY PANEL WITHOUT NO GFCI PROTECTION AS REQUIRED. THE 110 V BRA... | $2,400 | $0 | Jun 18, 2020 |
| Sep 6, 2019 | 39009024Z | RESOLVE | CLASS - 1 | I OBSERVED THE INSTALLATION OF 4 CONDUCTOR -# 10 AWG FLEXIBLE CABLE TO SUPPLY POWER TO A TEMPORARY PANEL ON THE ROOF.... | $1,600 | $0 | Jun 18, 2020 |
| Apr 11, 2019 | 38269207X | RESOLVE | CLASS - 2 | 52K2-RUSTED ROPES ON THE MACHINE CLEAN & MONITOR CONDITION | $655 | $0 | Jun 6, 2019 |
| Apr 10, 2018 | 32096650J | RESOLVE | CLASS - 2 | B254,34B BOILER ROOM FIRE DOOR NOT SELF CLOSING. CORRECT VIOLATING CONDITION OR SUBMIT CERTIFICATION OF CORRECTIONS | $0 | $0 | May 31, 2018 |
| Apr 2, 2018 | 35325189X | RESOLVE | CLASS - 2 | ELECTRICAL WORK W/O A PERMIT. OBSERVED IN BASEMENT, THE INSTALLATION OF (1) 30 CIRCUIT ELECTRICAL PANEL W/O 9 PANEL D... | $0 | $0 | May 17, 2018 |
| Dec 12, 2017 | 38259574Z | RESOLVE | CLASS - 1 | 5X10,1X10. 5X10 DOOR RESTRICTOR IS INOPERATIVE.THIS DEVICE ENSURES THESAFETY OF THE PASSENGERS,REPAIR.1X10 STOP SWITC... | $1,000 | $0 | Feb 1, 2018 |
| Dec 1, 2016 | 38251581K | RESOLVE | CLASS - 1 | 5X10,70Z2,100M7. 5X10 DOOR RESTRICTOR IS NOT WORKING REPAIR; 100M7-BRAKE TAG IS MISSING PROVIDE; 70Z2-CLEAN WATER IN ... | $1,000 | $0 | Jan 19, 2017 |
| Apr 22, 2016 | 35174199Y | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG WALLS & APPURTENANCES. NOTED: AT TIME OF INSPECTION(I)AT EXP#3 SPALLED W/FRACTURAL CRACKS AT... | $200 | $0 | Jun 9, 2016 |
| Apr 4, 2016 | 35177473L | RESOLVE | CLASS - 3 | OCCUPANCY CONTRARY TO THAT ALLOWED BY THE CERTIFICATE OF OCCUPANCY OR BUILDING DEPT RECORDS. COFO #121402 (AMENDED) I... | $0 | $0 | May 19, 2016 |
| Apr 4, 2016 | 35177471H | RESOLVE | CLASS - 2 | 27-766 AT CELLAR LEVEL GAS METER ROOM, NO FRESH AIR INLET (F.A.I.) RMDY: PROVIDE F.A.I. IN GAS METER ROOM | $0 | $0 | May 19, 2016 |
| Apr 4, 2016 | 35177472J | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: STORAGE OF COMBUSTIBLE MATERIALS IN CELLAR GAS METER RO... | $0 | $0 | May 19, 2016 |
| Sep 6, 2000 | 38107909Z | RESOLVE | Non-Hazardous | 37G12 37D06 74I11 74B15 37G12 PROPERLY FUSE RECTIFIEN. 37D06 PROPERLY SECURE RELAY REPY MOUNTING ON TO CONTROLLE. 74I... | $0 | $0 | Oct 26, 2000 |
| Sep 6, 2000 | 38107908R | RESOLVE | Non-Hazardous | 37D06 37O02 33L11 74D09 74X11 74B07 37D06 PROVIDE PROPERLY SECURE F CARD ON COORTROLLER. 33L11 REPARIS DEFECTING COUN... | $0 | $0 | Oct 26, 2000 |
| Jan 19, 1996 | 34133279R | RESOLVE | Non-Hazardous | ALTERED BUILDING OCCUPIED WITHOUT A VALID CERTIFICATE OF OCCUPANCY. ALTERED BUILDING OCCUPIED WITHOUT A VALID CERTIFI... | $350 | $0 | Mar 7, 1996 |
| May 31, 1995 | 34124394H | RESOLVE | Non-Hazardous | ALTERED BUILDING OCCUPIED WITHOUT A VALID CERIFICATE OF OCCUPANCY; AS REQUIRED BY ALT#415-88. LOCATIONS: CELLAR, FIRS... | $0 | $0 | Nov 2, 1995 |
| Apr 15, 1991 | 38004845R | RESOLVE | Non-Hazardous | 14M,74L,57O,74 ANUNCIATOR | $150 | $0 | May 30, 1991 |
| Feb 2, 1989 | 34018777X | RESOLVE | Hazardous | SUPERVISOR OR RIGGING EQUIPMENT SCAFFOLD WITHOUT SPECIAL RIGGERS LICENSE NO RIGGERS LICENSE ON JOB. | $1,000 | $0 | Jun 15, 1989 |