ECB violations
140 Riverside Drive, Manhattan • Block 01248 • Lot 0001
41 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Apr 13, 2023 | 39515371P | RESOLVE | CLASS - 2 | AT THE TIME OF INSPECTION, I OBSERVED OUTRIGGER BEAMS INSTALLED AND IN USE AT EXPO#1&4. UPON FURTHER INSPECTION, I OB... | $0 | $0 | Jun 22, 2023 |
| Oct 19, 2022 | 39507860X | RESOLVE | CLASS - 2 | AT THE TIME OF MY INSPECTION OF A ACTIVE 20 STORY FACADE REPAIR CONSTRUCTION SITE I OBSERVED 11 TREES WITHOUT PROTECT... | $0 | $0 | Dec 8, 2022 |
| Oct 19, 2022 | 39507856N | RESOLVE | CLASS - 2 | AT THE TIME OF MY INSPECTION OF A ACTIVE 20 STORY FACADE REPAIR CONSTRUCTION SITE I OBSERVED A LOADING PLATFORM INSTA... | $0 | $0 | Dec 8, 2022 |
| Apr 15, 2021 | 35556194Z | RESOLVE | CLASS - 1 | DOCS TO BE KEPT ON SITE ATOI I OBSERVED 2CHOOKS FOR SUSPENDED SCF@EXP3THAT HAD BACKLINES CONNECTED TO PARAPET CLAMPS.... | $6,250 | $0 | Sep 9, 2021 |
| Apr 15, 2021 | 35556195K | RESOLVE | CLASS - 1 | WORK CONTRARY TO CONST DOCS ATOI,I OBSERVED SWS INSTALLED@EXP1,3,4 INSTALLED USING 1.25"0HORIZ BRACES IN SEVERAL PLAC... | $625 | $0 | Feb 17, 2022 |
| Mar 10, 2021 | 39037413K | RESOLVE | CLASS - 1 | SPRINKLER INSTALLATION NOT IN ACCORDANCE TO CODE ON 03-10-2021 AT APPROX. 8:35AM I OBSERVED MULTIPLE SPRINKLERS HEADS... | $0 | $0 | Jul 22, 2021 |
| Mar 5, 2021 | 35550014P | RESOLVE | CLASS - 2 | PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATION(SIDEWALK SHED MAINTENCE). NOTED: AT THE TIME OF MY INSPECTION ... | $5,000 | $0 | Dec 9, 2021 |
| Nov 2, 2020 | 35542255X | RESOLVE | CLASS - 2 | FAILURE TO COMPLY WITH COMMISSIONERS ORDER TO FILE A CERTIFIATE OF CORRECTION WITH THE DOB.AS NOTED:AT TIME OF INSPEC... | $0 | $0 | Jun 3, 2021 |
| Jun 22, 2020 | 35538397J | RESOLVE | CLASS - 1 | OWNER FAILED TO REPAIR WITHIN THE "RECOMMENDED SWARMP DATE:2-1-2020" COMPLETED FACADE REPAIR OR FILE FOR EXTENDED DAT... | $2,500 | $0 | Sep 3, 2020 |
| Jun 1, 2018 | 35318792P | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN EXTERIOR BLDG WALLS AND APPURTENANCES. AT TIME OF INSPECTION I OBSERVED ON EXP#1 SOUTH ELEVATION.... | $1,250 | $0 | Sep 20, 2018 |
| Dec 1, 2017 | 35295669K | RESOLVE | CLASS - 1 | PARTIAL SWO ISSUED FOR SUSPENDED SCAFFOLD PURSUANT 28-207.2 & POSTED ON PREMISES. FAILURE TO PROVIDE SIDEWALK SHED WH... | $4,800 | $0 | Apr 26, 2018 |
| Apr 14, 2017 | 35253757P | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN EXTERIOR BUILDING AND APPURTENANCES. NOTE: NORTH ELEVATION EXPOSURE #2 REPAIRED VERTICAL CRACK OP... | $250 | $0 | Jul 13, 2017 |
| Nov 2, 2015 | 35159449M | RESOLVE | CLASS - 2 | ELECTRICAL WORK W/O A PERMIT. THE ENTIRE APT 4M: REMOVED EXISTING ELECTRICAL INSTALLATION RECEPTACLES OUTLETS,SWITCHE... | $400 | $0 | Dec 17, 2015 |
| Oct 27, 2015 | 35134849K | RESOLVE | CLASS - 1 | WORK W/O A PERMIT:@ TIME OF INSP @ APT 4M,REMOVAL OF FULL HEIGHT PARTITION WALLS THAT SEPERATED THE BATHRM & THE KITC... | $800 | $0 | Dec 17, 2015 |
| Oct 27, 2015 | 35134848Z | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BLDG IN A CODE COMPLIANT MANNER.@ TIME OF INSP,IN APT 4M,REMOVAL OF FIRE RATING IN BETWEEN APTS,E... | $1,000 | $0 | Dec 17, 2015 |
| Oct 27, 2015 | 35134850H | RESOLVE | CLASS - 2 | FAILURE TO PROVIDE COVER/FACEPLATE/FOR OUTLETS,LUMINARES.@ TIME OF INSP IN APT 4M,OPEN OUTLET BOXES,OPEN LIGHT SWITHC... | $250 | $0 | Dec 17, 2015 |
| Aug 12, 2015 | 35123523R | RESOLVE | CLASS - 1 | ELECTRICALLY WORK W/O A PERMIT.ENTIRE APT.9L:SUB PANEL,BRANCH CIRCUIT WIRING,RECEPTACLES OUTLETS,SWITCHES,LIGHTING FI... | $400 | $0 | Jan 7, 2016 |
| Aug 12, 2015 | 35123524Z | RESOLVE | CLASS - 2 | FAILURE TO PROVIDE ARC-FAULT CIRCUIT INTERPRETER(ADCI)PROTECTION IN DWELLING UNITS.THE ENTIRE APT.9L:3BEDROOM,LIVING ... | $1,200 | $0 | Jan 7, 2016 |
| Aug 12, 2015 | 35159125X | RESOLVE | CLASS - 2 | FAILURE TO PROPERLY BAND ELECTRICAL SYSTEMS.BSMT SERVICE SWITCHES:ALL SIX=600 AMP SERVICE SWITCHES ARE NOT BONDED TO ... | $750 | $0 | Jan 7, 2016 |
| Jan 8, 2013 | 34990545R | RESOLVE | CLASS - 2 | WORK DOES NOT CONFORM TO APPROVED CONST DOCUMENTS AND/OR APPROVED AMENDMENTS. USING 3FT PIPEFRAME AS BENCHMAKR FOR OU... | $0 | $0 | Feb 28, 2013 |
| Jan 8, 2013 | 34990546Z | RESOLVE | CLASS - 2 | TEMP CONSTRUCTION EQUIPMENT ON SITE-EXPIRED PERMIT. EXPIRED SHED PERMIT #120458744 EXPIRED 12/31/12. REMEDY:COMPLY WI... | $0 | $0 | Apr 19, 2013 |
| Jun 27, 2012 | 38222480Z | RESOLVE | CLASS - 1 | SEC. 28-116.4.1. 45R07. OPERATING A DEVICE W/A C/COMPLIANCE. NO REPORTOF INSPECTION SUBMITTED TO DOB AND NO WITNESSIN... | $1,600 | $0 | Aug 16, 2012 |
| Jan 28, 2012 | 34937974M | RESOLVE | CLASS - 2 | WORK W/O A PERMIT NOTED THE FOLLOWING CONDITIONS: BUILDING 140 RIVERSIDE DRIVE HAS INSTALLED A CURB CUT WHICH REPRESE... | $400 | $0 | Mar 15, 2012 |
| Oct 17, 2011 | 34752321Y | RESOLVE | CLASS - 3 | SEC. 715.4.9. FAILURE TO PROVIDE LABEL/OR OTHER IDENTIFICATION SHOWINGTHE NAME OF THE MANUFACTURER, THE TEST STANDARD... | $300 | $0 | Feb 2, 2012 |
| Sep 1, 2011 | 34926459Y | RESOLVE | CLASS - 2 | 3310.6MISC.VIO.FAILURE TO HAVE DESIGNATED SITE SAFETY MANAGER AS INDICATED ON PW-2 PRESENT ON SITE AT MINIMUM OF ONCE... | $0 | $0 | Oct 20, 2011 |
| Jan 22, 2003 | 32041033X | RESOLVE | Non-Hazardous | 50A/50B. 50A INSTALL DISCHARGE PIPING ON DOMESTIC WATER RELIEF VALVES 50B REPAIR OR REPLACE LOOSE AND DAMAGE INSULATI... | $180 | $0 | Mar 13, 2003 |
| Jan 22, 2003 | 32041032Y | RESOLVE | Non-Hazardous | 50A/50B/50C. 50A REMOVE THREADED ENDS ON SAFETY VALVES DISCHARGE PIPING. 50B INSTALL DISCHARGE PIPING ON DOMESTIC WAT... | $180 | -$180 | Mar 13, 2003 |
| Jan 22, 2003 | 32041034H | RESOLVE | Non-Hazardous | 50A BOILER NOT PROPERLY DISCONECTED MUST BE MAINTAINED IF NOT DISCONECTED. REMEDY: BOILER MUST BE TO ALL DISCONECTED ... | $180 | $0 | Mar 13, 2003 |
| Sep 28, 1999 | 38090415K | RESOLVE | Non-Hazardous | 50Y,35D,31D,31D,30R. REPAIR MACHINE OIL LEAK. REMOVE TEMP WIRING THUR MOTOR ROOR FLOOR AND HOIST WAY. REMOVE TEMP WIR... | $0 | $0 | Nov 18, 1999 |
| Sep 28, 1999 | 38090414Z | RESOLVE | Non-Hazardous | 35D,35L,35R,50D,3D,20X,30D. REMOVE OLD PIPE AND WIRING AT CEILING ABOVE. REPAIR SMOKE HOLE SEATING AND SECURE. REMOVE... | $0 | $0 | Nov 18, 1999 |
| Jul 3, 1996 | 38057012L | RESOLVE | Non-Hazardous | 50Y.#50-SEAL MACHINE AND STOP OIL LEAK. | $0 | $0 | Sep 12, 1996 |
| Jul 2, 1996 | 38057010H | RESOLVE | Non-Hazardous | 50Y,57O.#50-SEAL MACHINE OF FOIL LEAK.#57-CLEAN PIT. | $0 | $0 | Sep 12, 1996 |
| Jul 2, 1996 | 38057011J | RESOLVE | Non-Hazardous | 46R,50Y.#46-SHORTEN HOIST ROPES.#50-PROPERLY SEAL MACHINE OIL LEAK. | $0 | $0 | Sep 12, 1996 |
| Jun 10, 1993 | 38034345H | RESOLVE | Non-Hazardous | 62M 34I 57O 22D 15J 37L 62M TOE GUARD 15J 1ST FLOOR DOOR 37 REPAIR RELAY AND RESISTOR | $0 | $0 | Aug 5, 1993 |
| Jun 10, 1993 | 38034346J | RESOLVE | Non-Hazardous | 54D, 34I, 22D, 57O, 74M. | $0 | $0 | Aug 5, 1993 |
| Jun 10, 1993 | 38034347L | RESOLVE | Non-Hazardous | 46H. | $0 | $0 | Aug 5, 1993 |
| Jun 10, 1993 | 38034348N | RESOLVE | Non-Hazardous | 03E. 03-E) CAB IS HITTING DOOR ROLLERS. | $0 | $0 | Aug 5, 1993 |
| Jun 10, 1993 | 38034349P | RESOLVE | Non-Hazardous | 07L, 09H, 35D. 07-L) DETECTOR EDGE 35-D) SMOKE HOLE GRATING. | $0 | $0 | Aug 5, 1993 |
| Nov 15, 1991 | 34062721P | RESOLVE | Hazardous | SUPERVISION OR USE OF RIGGING EQUIPMENT WITHOUT A SPECIAL RIGGEERS LICENSE NOTED: PAINTING & REPLACING BRICKS AT NORT... | $0 | $0 | Jan 2, 1992 |
| Mar 25, 1991 | 34054741M | RESOLVE | Hazardous | NO CONTRACTORS SIGN ON JOB SITE. AT TIME OF INSPECTION THERE NERE NO SIGNS POSTED. REMEDY: PROVIDE SIGNS AS PER N.Y.C... | $345 | $0 | Jun 13, 1991 |
| Mar 25, 1991 | 34054740K | RESOLVE | Hazardous | NO PERMIT FOR SIDEWALK SHED. AT TIME OF INSPECTION THERE WAS NO PERMIT FOR THE SIDEWALK SHED PRESENT THERE WERE MEN W... | $500 | $0 | May 10, 1991 |