ECB violations
321-325 West 94 Street, Manhattan • Block 01253 • Lot 0007
28 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Jun 27, 2026 | 39194046R | ACTIVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER. AT TIME OF INSPECTION OBSERVED A DAMAGED CORNICE AT LEFT SID... | $1,250 | $1,250 | Sep 3, 2026 |
| Jul 30, 2021 | 35414200M | ACTIVE | CLASS - 2 | OCCUPANCY CONTRARY TO THAT ALLOWED BY THE CERTIFICATE OF OCCUPANCY OR BUILDING DEPARTMENT RECORDS.RECORDS INDICATE A ... | $1,250 | $0 | Dec 30, 2021 |
| Jul 30, 2021 | 35414201Y | RESOLVE | CLASS - 2 | WORK WITHOUT PERMIT.NOTED AT CELLAR LEVEL ERECTED FULL HEIGHT PARTITIONS WITH DOORS CREATING A (3)PIECE BATHROOM AND ... | $0 | $0 | Dec 30, 2021 |
| Jun 28, 2021 | 35242191L | ACTIVE | CLASS - 2 | OCCUPANCY CONTRARY TO ALLOWED BY C OF O AND DEPT OF BUILDINGS RECORDS STUD AND SHEETROCK WALLS ERECTED FROM FLOOR TO ... | $1,280 | $0 | Feb 3, 2022 |
| Mar 1, 2021 | 35526649Z | RESOLVE | CLASS - 2 | FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATION#39034074L ISSUED ON 12/30/2020 AND TO ... | $0 | $0 | Jul 15, 2021 |
| Dec 30, 2020 | 39034074L | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD ALL PERSONS AND PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS. AT THE TIME OF INSPECTION OBSERVED... | $0 | $0 | Jul 15, 2021 |
| Nov 21, 2018 | 35371140M | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BLDG APPURTENANCES AT TIME OF INSPECTION ON AN OCCUPIED BUILDING, I OBSERVED AT THE REA ROF THE B... | $2,500 | $0 | Sep 5, 2019 |
| Jan 11, 2018 | 35274564L | RESOLVE | CLASS - 2 | ELECTRICAL WORK WITHOUT A PERMIT.OBSERVED @ 10:00 AM OUTLETS INSTALLEDIN APT 2NE BOILERS,BASEMENT APARTMENT & OFFICE.... | $400 | $0 | Mar 9, 2018 |
| Jan 10, 2018 | 35274567R | ACTIVE | CLASS - 2 | FAILURE TO PROVIDE ADEQUATE CIRCUIT OVERCURRENT PROTECTION DEVICE PER TABLE.NUMBER ONE OUGHT WIRE IN 400 AMP FUSED @ ... | $2,400 | $0 | Mar 9, 2018 |
| Jan 10, 2018 | 35274566P | ACTIVE | CLASS - 2 | EC110-14A DOUBLE LUGGING IN 400 AMP SERVICE SWITCH IN BASEMENT.LUGS NOT SUITABLE FOR INTENDED PURPOSE.REM:COMPLY WITH... | $800 | $0 | Mar 9, 2018 |
| Jan 10, 2018 | 35268419Y | RESOLVE | CLASS - 1 | WORK WITHOUT A PERMIT. I OBSERVED IN BASEMENT AN ILLEGAL APARTMENT WITH FULL KITCHEN WITH GAS STOVE AND WATER WASTE A... | $0 | $0 | Mar 9, 2018 |
| Jan 10, 2018 | 35268420L | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. I OBSERVED IN BASEMENT BOILER ROOM AN OPEN ENDED GAS PIPE WITH... | $1,000 | $0 | Mar 9, 2018 |
| Jan 10, 2018 | 35274565N | RESOLVE | CLASS - 2 | UNAPPROVED,UNSAFE,UNSUITABLE ELCTRICAL EQUIPMENT DEVICES APPARATUS APPLIANCES MATERIALS OR WIRING IN USE.INSUFFICIENT... | $800 | $0 | Mar 9, 2018 |
| May 23, 2017 | 35249263N | RESOLVE | CLASS - 2 | FAILURE TO SAFEGUARD ALL PERSONS AND PROPERTY AFFECTED BY CONSTURCTIONOPERATIONS. OBSERVED IN APT 6W CLOSET WALL A SE... | $5,000 | $0 | Sep 21, 2017 |
| Jan 10, 2017 | 35255863H | RESOLVE | CLASS - 2 | RESIDENCE ALTERED FOR OCCUPANCY AS A DWELLING FOR MORE THAN THE LEGALLY APPROVED #'S OF FAMILIES. DOB'S RECORDS INDIC... | $0 | $0 | Mar 1, 2018 |
| Jan 10, 2017 | 35255862X | RESOLVE | CLASS - 1 | WORK W/O A PERMIT. WORK NOTED: A BASEMENT/CELLAR LEVEL,ERECTED FULL HEIGHT PARTITIONS,CREATING A BATHROOM,2 ROOMS,LIV... | $1,600 | $0 | Mar 9, 2018 |
| Dec 2, 2016 | 38251659L | RESOLVE | CLASS - 1 | 5X10 DOOR ZONE RESTRICTOR RENDERED INOPERATIVE REPAIR. | $1,000 | $0 | Mar 16, 2017 |
| May 4, 2016 | 38242625Z | RESOLVE | CLASS - 2 | 549U15,68B07,41I10,37I10. NO TAG ON CONTROLLER STATING DATE OF BRAKE MAINTENANCE, NO ENTRY OF DATE OF BRAKE MAINTENAN... | $0 | $0 | Jun 23, 2016 |
| May 27, 2015 | 35153874X | RESOLVE | CLASS - 2 | WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS &/OR APPROVEDAMENDMENTS WORK NOTED: REMOVED SUB FLOORING & F... | $0 | $0 | Jul 16, 2015 |
| Mar 19, 2014 | 35038861N | RESOLVE | CLASS - 2 | FAILURE TO PROPERLY BOND ELECTRICAL SYSTEMS BSMT SERVICE EQUIPMENT: 400AMP SERVICE SWITCH NEAUTRAL BAR NOT BONDED TO ... | $750 | $0 | May 8, 2014 |
| Mar 19, 2014 | 35038862P | RESOLVE | CLASS - 2 | UNAPPROVED/UNSAFE/UNSUITABLE ELECTRICAL EQUIPMENT,APPURATES,MATERIALS,DEVICES,APPLIANCES OR WIRING IN USE. BSMT: DEFE... | $400 | $0 | May 8, 2014 |
| Apr 12, 2011 | 38215556K | RESOLVE | CLASS - 2 | 51L10,40B10,99BB05,39BB12,33BB12,32H10 51L REPAIR SLACK CABLE SW TO BEMANUAL RESET 40B-SERVICE FIRE EXTINGUISHER IN M... | $250 | $0 | Jun 2, 2011 |
| Feb 10, 2009 | 38200588N | RESOLVE | CLASS - 2 | 51B07.61M07.40M07.51 SLACK CABLE SW. MUST BE MANUALLY RESETTING REMOVE WEIGHT FROM SW. 61 PROVIDE EMG. SVC NUM. ON MA... | $2,500 | $0 | Apr 2, 2009 |
| May 14, 1999 | 32017318J | RESOLVE | Non-Hazardous | 49-NO ACCESS TO BOILER RM. NO SUPER ON PREMISES. NO KEY TO BOILER RMON PREMISES. | $0 | $0 | Jul 8, 1999 |
| Sep 11, 1996 | 34145853K | RESOLVE | Non-Hazardous | WORK WITHOUT A PERMIT.WORK NOTED RENOVATION TO ENTIRE APT WITH NEW WO-OD FLOORS SHEETROCK WALLS AND CEILING.NEW BATHR... | $350 | $0 | Oct 31, 1996 |
| Jun 1, 1996 | 38055349H | RESOLVE | Non-Hazardous | 05L 08V 18Q PROVIDE ALL COVERS WHERE NECCESSARY 14M | $0 | $0 | Apr 3, 1997 |
| Aug 19, 1992 | 38028036N | RESOLVE | Non-Hazardous | 57O,35P. | $0 | $0 | Nov 12, 1992 |
| Jun 18, 1991 | 38013468P | RESOLVE | Non-Hazardous | 33W,22D,09M,73O,18#,08V,18# ELEVATOR STOPS IN MOTION BY PULLING 3RD FLR DOOR | $0 | $0 | Feb 6, 1992 |