ECB violations
12-14 West 47 Street, Manhattan • Block 01262 • Lot 0045
25 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Oct 19, 2022 | 37022954Z | ACTIVE | CLASS - 2 | FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 8C REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WA... | $1,250 | $0 | Feb 9, 2023 |
| Oct 4, 2022 | 39507156M | RESOLVE | CLASS - 2 | AT TIME OF INSPECTION OF CLASS 1 VIO#35646585P ISSUED ON 07-21-22, OBSERVED JOB SITE IS CLOSED UNABLE TO VERIFY CONDI... | $625 | $0 | Dec 8, 2022 |
| Aug 29, 2022 | 39505713R | RESOLVE | CLASS - 1 | OBSERVED 16FT HIGH CONSTRUCTION FENCE AT EXP 1 AND CHAINLINK FENCE AT EXP 3 CONTRARY TO PROVIDED DESIGN DRAWINGS THAT... | $625 | $0 | Dec 1, 2023 |
| Aug 29, 2022 | 39505711N | RESOLVE | CLASS - 1 | IN RESPONSE TO INCIDENT OBSERVED DEMOLITION PERFORMED OUT OF SEQUENCE - APPROVED PLANS STATE THAT ONLY 1 FL TO BE DEM... | $625 | $0 | Dec 1, 2023 |
| Aug 29, 2022 | 39505710L | RESOLVE | CLASS - 1 | IN RESPONSE TO ACCIDENT - PLYWOOD FENCE SECTION COLLAPSED ON SIDEWALK AT EXP1 FROM BEING HIT BY A FALLEN CONCRETE SLA... | $0 | $0 | Dec 1, 2023 |
| Jul 21, 2022 | 35646585P | RESOLVE | CLASS - 1 | FAILURE TO NOTIFY DEPT OF INCIDENT THAT RESULTED IN FATALITY OR INJURYNOTE: WORKER HIT BY BOBCAT MACHINE INJURED ARM ... | $1,250 | $0 | Nov 10, 2022 |
| Jun 15, 2022 | 39502274K | RESOLVE | CLASS - 1 | AT THE TIME OF INSPECTION OF 14 STORY DEMOLITION SITE OBSERVED, STANDPIPE ERECTED IN PLACE UP TO 7TH FLOOR, UPON REVI... | $0 | $0 | Jan 19, 2023 |
| Jun 15, 2022 | 39502273Z | RESOLVE | CLASS - 1 | AT THE TIME OF INSPECTION RESPONDING TO AN INCIDENT WHERE THE WORKER JULIO ZAMBRANO WAS PICKING MATERIAL UP FROM 1ST ... | $0 | $0 | Jan 19, 2023 |
| May 28, 2022 | 39501777H | RESOLVE | CLASS - 1 | NO WATCH PERSON ON SITE... NOTE:AT THE TIME OF INSPECTION OBSERVED SITE CLOSED, NO DEMO ACTIVITY, ALSO OBSERVED BUILD... | $625 | $0 | Jul 14, 2022 |
| Mar 22, 2022 | 35641039P | RESOLVE | CLASS - 1 | 3301.1.2 USE OF DIESEL GENERATOR UNIT WITHOUT FDNY PERMIT.AT THE TIME OF INSPECTION OF A PROPOSED 14 STORY ACTIVE DEM... | $0 | $0 | Mar 17, 2023 |
| Mar 22, 2022 | 35641041Y | RESOLVE | CLASS - 1 | SITE SPECIFIC SAFETY ORIENTATION PROGRAMME FOR ALL WORKERS(TORCH-OPERATION)AT THE TIME OF INSPECTION OF A PROPOSED 14... | $0 | $0 | Dec 1, 2023 |
| Mar 22, 2022 | 35641040M | RESOLVE | CLASS - 1 | 3306.9.10.3 PROTECTION OF FLOOR OPENINGS.AT THE TIME OF INSPECTION OF A PROPOSED 14 STORY ACTIVE DEMO JOBSITE I OBSER... | $2,500 | $0 | Dec 1, 2023 |
| Mar 22, 2022 | 35641036J | RESOLVE | CLASS - 1 | 3301.6 DESIGN DRAWING(SHORING)AT THE TIME OF INSPECTION OF A PROPOSED 14 STORY ACTIVE DEMO JOBSITE I OBSERVE SHORING ... | $0 | $0 | Mar 17, 2023 |
| Mar 22, 2022 | 35641037L | RESOLVE | CLASS - 1 | FAILURE TO REMOVE GLASS PRIOR TO THE COMMENCEMENT OF DEMOLITION OPERATIONS.AT THE TIME OF INSPECTION OF A PROPOSED 14... | $0 | $0 | Mar 17, 2023 |
| Mar 22, 2022 | 35641038N | RESOLVE | CLASS - 1 | 3309.14 WINDOW PROTECTION AT THE TIME OF INSPECTION OF A PROPOSED 14 STORY ACTIVE DEMO JOBSITE I OBSERVE IN MULTIPLE ... | $0 | $0 | Mar 17, 2023 |
| Feb 13, 2020 | 37018238X | RESOLVE | CLASS - 2 | FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 8C REPORT OF CRITICAL EXCAMINATION DOCUMENTING CONDITION OF EXTERIOR W... | $1,250 | $0 | May 28, 2020 |
| Nov 15, 2019 | 37016501P | RESOLVE | CLASS - 2 | AC279291-FAILURE TO COMPLETE THE INSTALLATION OF FULL SYSTEM OF AUTOMATIC SPRINKLERS AND FILE A FINAL SPRINKLER REPOR... | $0 | $0 | Jul 9, 2020 |
| Aug 10, 2010 | 38212453Y | RESOLVE | CLASS - 3 | 98/M/05,68/M/07-98-M-05-PERFORM 5YR TEST & FILE/68-M-07-PROVIDE MAINTENACE LOG WITH ACCURATE INFORMATION | $100 | $0 | Sep 30, 2010 |
| Aug 10, 2010 | 38212452M | RESOLVE | CLASS - 3 | 100/BB/09,68/M/07,100-BB-09REMOVE OLD 2YR TEST TAG/68-M-07-PROVIDE MAINTENACE LOG WITH ACCURATE INFORMATION. | $100 | $0 | Sep 30, 2010 |
| Aug 10, 2010 | 38212451K | RESOLVE | CLASS - 3 | 100/BB/09,98/M/05,68/B/07-100-BB-09-REMOVE OLD 2YR TEST TAG/98-M-05--PERFORM & FILE 5YR TEST/68-B-09-PROVIDE MAINTENA... | $100 | $0 | Sep 30, 2010 |
| Jan 27, 2010 | 36012228Z | RESOLVE | CLASS - 2 | FAILURE TO FILE AN ARCHITECT / ENGINEER REPORT CERTIFYING EXIT / DIRECTIONAL SIGNS ARE CONNECTED TO EMERGENCY POWER S... | $0 | $0 | Sep 23, 2010 |
| Sep 9, 1998 | 38079264P | RESOLVE | Non-Hazardous | 73I- REPAIR DAMAGES TO ELEVATOR AND TO BE TESTED BY A CITY INSPECTOR FROM THE BUILDING DEPARTMENT BEFORE PUT IN SERVICE. | $0 | $0 | Oct 29, 1998 |
| Sep 9, 1998 | 38079263N | RESOLVE | Non-Hazardous | 73I- REPAIR DAMAGES TO ELEVATOR AND TO BE TESTED BY A CITY INSPECTOR FROM THE BUILDINGS DEPARTMENT BEFORE PUT IN SERV... | $0 | $0 | Oct 29, 1998 |
| Apr 3, 1998 | 38072765L | RESOLVE | Non-Hazardous | 75U 75-PERFORM & YEAR TEST. | $350 | $0 | May 28, 1998 |
| Jul 17, 1995 | 34123070R | RESOLVE | Non-Hazardous | FAILURE TO PROVIDE EMERGENCY POWER TO EXIT SIGNS IN CORRIDORS THROUGH-OUT BUILDING. REMEDY: PROVIDE EMERGENCY POWER E... | $400 | $0 | Sep 7, 1995 |