ECB violations
1-11 West 47 Street, Manhattan • Block 01263 • Lot 0034
46 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Jun 17, 2024 | 37028847K | RESOLVE | CLASS - 2 | A.C. 27.929.1, FAILURE TO COMPLETE THE INSTALLATION OF A FULL SYSTEM OF AUTOMATIC SPRINKLERS AND FILE A FINAL SPRINKL... | $0 | $0 | Jan 8, 2026 |
| Jul 13, 2020 | 37019843Z | RESOLVE | CLASS - 2 | AC 27-929 FAILURE TO COMPLETE THE INSTALLATION OF A FULL SYSTEM OF AUTOMATIC SPRINLERS AND FILE A FINAL SPRINKLER REP... | $0 | $0 | Apr 1, 2021 |
| Nov 15, 2019 | 37016509J | ACTIVE | CLASS - 2 | AC279291-FAILURE TO COMPLETE THE INSTALLATION OF A FULL SYSTEM OF AUTOMATIC SPRINKLERS AND FILE A FINAL SPRINKLER REP... | $1,250 | $0 | Feb 20, 2020 |
| Feb 16, 2018 | 35295048H | ACTIVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING EXTERIOR BUILDING WALLS AND APPURTENANCES.NOTED:AT W 47 ST SIDE EXTERIOR WALL,OBSERVED M... | $250 | $0 | Apr 5, 2018 |
| Jun 20, 2017 | 37002961Z | RESOLVE | CLASS - 2 | FAILURE TO FILE ANNUAL CERTIFICATION THAT COOLING TOWER 1000005151 HASBEEN INSPECTED,TESTED,AND DISINFECTED AND THAT ... | $1,000 | $0 | Dec 7, 2017 |
| Jun 20, 2017 | 37002960R | RESOLVE | CLASS - 2 | FAILURE TO FILE ANNUAL CERTIFICATION THAT COOLING TOWER 1000005150 HASBEEN INSPECTED,TESTED,AND DISINFECTED AND THAT ... | $1,000 | $0 | Dec 7, 2017 |
| Jun 20, 2017 | 37002959J | RESOLVE | CLASS - 2 | FAILURE TO FILE ANNUAL CERTIFICATION THAT COOLING TOWER 1000005148 HASBEEN INSPECTED,TESTED,AND DISINFECTED AND THAT ... | $1,000 | $0 | Dec 7, 2017 |
| Jun 20, 2017 | 37002962K | RESOLVE | CLASS - 2 | FAILURE TO FILE ANNUAL CERTIFICATION THAT COOLING TOWER 1000005152 HASBEEN INSPECTED,TESTED,AND DISINFECTED AND THAT ... | $2,000 | $0 | Dec 7, 2017 |
| Jun 20, 2017 | 37002963M | RESOLVE | CLASS - 2 | FAILURE TO FILE ANNUAL CERTIFICATION THAT COOLING TOWER 1000005153 HASBEEN INSPECTED,TESTED,AND DISINFECTED AND THAT ... | $1,000 | $0 | Dec 7, 2017 |
| Jul 8, 2016 | 35167082P | RESOLVE | CLASS - 2 | FAILURE TO PROVIDE APPROVED/ACCEPTED PLANS AT JOB SITE.AT TIME OF INS PECTION OBSERVED WORKERS WORKING OUTSIDE BUILDI... | $0 | $0 | Jul 25, 2016 |
| Dec 16, 2015 | 35162533M | RESOLVE | CLASS - 1 | BC3303.8.1.5 STANDPIPE DUAL SYSTEM.@ TIME OF INSPECTION STANDPIPE CONNECTION TO SPRINKLER SYSTEM IS BEING MODIFIED.NO... | $1,600 | $0 | Feb 4, 2016 |
| Oct 19, 2015 | 35131566R | RESOLVE | CLASS - 1 | WORK WITHOUT A PERMIT EXPIRED PERMIT.NOTE:AT TIME OF INSPECTION OBSERVED WORK IN PROGRESS RENOVATION OF LOBBY AND PER... | $800 | $0 | Dec 10, 2015 |
| Sep 21, 2015 | 37000095M | RESOLVE | CLASS - 2 | 28-317.3 FAILURE TO REGISTER COOLING TOWER. RMDY:COMPLY W/CODE | $0 | $0 | Nov 12, 2015 |
| Sep 16, 2015 | 35145299Z | RESOLVE | CLASS - 1 | FAILURE TO COMPLY W/NYC FIRE CODE. NO PERMIT FOR STORAGE OF OXYGEN & ACETYLENE OBSERVED ON MEZZENINE LEVEL AT JOB SIT... | $2,400 | $0 | Nov 5, 2015 |
| Sep 16, 2015 | 35131150N | RESOLVE | CLASS - 1 | WORK DOES NOT CONFORM TO APPROVED PLANS & APPLICATION. DEMO IN PROGRESS CHIPPING SLAB OF 2ND FL SEQUENCE PROVIDED BY ... | $1,000 | $0 | Nov 5, 2015 |
| Sep 16, 2015 | 35145297P | RESOLVE | CLASS - 2 | SEC. 28-105.1 WORK W/O PERMITS-EXPIRED PERMIT NOTE WORK IN PROGRESS UNDER PERMIT #122135796 EXPIRED 9/9/15 DEMO OF 2N... | $400 | $0 | Nov 5, 2015 |
| Sep 16, 2015 | 35145298R | RESOLVE | CLASS - 2 | FAILURE TO SAFEGUARD ALL PERSONS & PRPERTY AFFECTED BY CONSTRUCTION OPERATION USE OF TEMPORARY SAFETY EQUIPMENT & SAF... | $1,200 | $0 | Nov 5, 2015 |
| Jun 19, 2015 | 35132069K | RESOLVE | CLASS - 1 | 3314.8 THE OPEN SIDES AND ENDS OF SCAFFOLD PLATFORMS SHALL BE PROVIDED WITH A GUARDRAIL SYSTEM.NOTED:@ THE TIME OF IN... | $1,600 | $0 | Aug 6, 2015 |
| Jun 19, 2015 | 35132068Z | RESOLVE | CLASS - 2 | WORK DOES NOT CONFORM TO CD5.NOTED:AT TIME OF INSP.ANCHOR PLATE ON CD5 SHOW 10"LONG THE ANCHOR PLATE IS ABOUT 24"LONG... | $0 | $0 | Aug 6, 2015 |
| Jun 19, 2015 | 35132067R | RESOLVE | CLASS - 2 | PSWO ALL EXTERIOR WORK.WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS.NOTED:AT TIME OF INSP.THERE ARE NO DE... | $0 | $0 | Aug 6, 2015 |
| Dec 17, 2014 | 35150139X | RESOLVE | CLASS - 2 | PARTIAL STOP WORK ORDER FOR SUSPENDED SCAFFOLD ISSUED PURSUANT TO 28-207.2 AND POSTED @ PREMISES WORK DOES NOT CONFOR... | $530 | $0 | Feb 5, 2015 |
| Dec 17, 2014 | 35150138Y | RESOLVE | CLASS - 1 | 3314.15.2 PARTIAL WORK ORDER FOR SUSPENDED SCAFFOLD ISSUED PURSUANT TO 28-207.2 AND POSTED @ PREMISES STIRRUPS LOCATI... | $1,630 | $0 | Feb 5, 2015 |
| Dec 17, 2014 | 35150140N | RESOLVE | CLASS - 1 | 3314.PARTIAL STOP WORK ODER FOR SUPPORTED SCAFFOLD ISSUED PURSUANT TO 28-207.2 AND POSTED @ PREMISES UNSAFE CONDITION... | $1,630 | $0 | Feb 5, 2015 |
| Dec 8, 2014 | 35109396M | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS. AT TIME OF INSPECTION OBSERVED SIDEW... | $2,430 | $0 | Jan 22, 2015 |
| Dec 8, 2014 | 35109394Z | RESOLVE | CLASS - 1 | WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS &/OR APPROVEDAMENDMENTS. AT TIME OF INSPECTION OBSERVED,WORK... | $1,030 | $0 | Jan 22, 2015 |
| Dec 8, 2014 | 35109395K | RESOLVE | CLASS - 1 | SEC. 3301.7 DESIGN DRAWING REQUIRED BY CHAPTER 33. AT TIME OF INSPECTION OBSERVED,PLATFORM CONSTRUCTED ON THE 30TH FL... | $1,600 | $0 | Feb 26, 2015 |
| Jun 13, 2014 | 38231193K | RESOLVE | CLASS - 2 | 16B03,34B03.16B03 HOISTWAY DOOR EXCESSIVE GAP 4&1/2"OPENING STRIKE POST TO CAR INSTALL GUARDS.34B03 HOISTWAY SHAFT BE... | $0 | $0 | Jul 31, 2014 |
| Apr 9, 2014 | 35092233J | RESOLVE | CLASS - 1 | FAIL TO HAVE SITE SAFETY MANAGER.NOTE:OBS SUSPENDED RIGS SET-UP @EXP #1(AVE 5) & EXP #2(W11 W 47 ST) W/WORKERS INSIDE... | $1,200 | $0 | May 29, 2014 |
| Apr 9, 2014 | 35092234L | RESOLVE | CLASS - 2 | EXPIRED PERMIT.NOTE:OBSERVED SIDEWALK SHED ERECTED @EXP #1(5 AVE) & 2(W 47).PERMIT #121413283 EXPIRED 6/28/13.DOB REC... | $0 | $0 | May 29, 2014 |
| Apr 9, 2013 | 35015302P | RESOLVE | CLASS - 2 | SIDEWALK SHED DOES NOT MEET CODE SPECIFICATIONS. NOTED: NO ACCURATE EMERGENCY CONTACT INFO ON SIGNATE FOR SHED #12141... | $2,400 | $0 | Aug 8, 2013 |
| May 20, 2008 | 38185127H | RESOLVE | Non-Hazardous | 38P16.66P16.60M07.02X10.59X10.86BB05. 38P PROVIDE ACCESS TO TOP OF CAR 66P PROVIDE ACCESS TO PITY 60M PROVIDE EMERGEN... | $350 | $0 | Jul 10, 2008 |
| Nov 18, 2005 | 38155169Z | RESOLVE | Non-Hazardous | 55M11. 55- INSTALL ROPE GUARDS. ON MACHINE. | $180 | $0 | Jan 5, 2006 |
| Nov 18, 2005 | 38155170X | RESOLVE | Non-Hazardous | 55M11. 55- INSTALL ROPE GUARDS ON MACHINE. | $180 | $0 | Jan 5, 2006 |
| Nov 18, 2005 | 38155171H | RESOLVE | Non-Hazardous | 55M11. 55- INSTALL ROPE GUARDS ON MACHINE. | $180 | $0 | Jan 5, 2006 |
| May 21, 2003 | 38138289Z | RESOLVE | Non-Hazardous | 01#11 06A12 (01) EMERGAENCY STOP SWITCH IN CAR HAS NO SOUND ON ACTIVATION (06) CAR GATE ROTTER IS DEFECTIVE - REPLACE. | $350 | -$350 | Jul 10, 2003 |
| Apr 17, 2003 | 38137601J | RESOLVE | Non-Hazardous | 2E11-52M07-36O02. 42-MADE REPAIR TO GOVERNOR TO REMOVE RILIRATIOR. 52-PROVIDE CARE GOVERNOR ON MAIN MACHINE 36-CLEAN ... | $0 | $0 | Jun 5, 2003 |
| May 23, 2002 | 38123274Y | RESOLVE | Non-Hazardous | 37M07-40F11-41M12. 37-M-07 MISSING ID TAG PROVIDE CITY ID TAG ON CONTROLLER 40-F-11 GOVENOR WOBBLES DURING MOTION REP... | $350 | $0 | Jul 11, 2002 |
| May 23, 2002 | 38123275X | RESOLVE | Non-Hazardous | 35I12/35B04/ 35I12=REPLACE BROKEN WINDOWS IN MACHINE ROOM 35B04=PATCH UP 6"HOLE ON MOTOR ROOM FLOOR | $180 | $0 | Jul 11, 2002 |
| May 23, 2002 | 38123728J | RESOLVE | Non-Hazardous | 37U16/54U16/50U16/44U16/ 37-54-50-44 ALL ARE NOT TAGED PROPERLY TAG ALL DEVICES WITH CITY ID TAG AND NUMBER 1P16430 | $180 | $0 | Jul 11, 2002 |
| Jan 2, 2002 | 38119680H | RESOLVE | Non-Hazardous | 73X11/ 57U05/ 35O02/ RETURN TO SERVICE SO THAT A COMPLTE INSP. MAY BE MADE BY THIS DEPT. 57 - U - 05 PERFORM FOR 5YR ... | $350 | $0 | Feb 21, 2002 |
| Jan 2, 2002 | 38119681J | RESOLVE | Non-Hazardous | 75U05/ 57O02/ 46O02/ 50O02/ PERFROM FIEL 5 YR GOV. TEST | $350 | $0 | Feb 21, 2002 |
| Nov 29, 2001 | 38119311M | RESOLVE | Non-Hazardous | 53X11-35B07-50O02-35I11-35O02-73U16-22D06-62X11-55X11. 53-X-11 REPAIR LIGHTING 35-B-07 PROVIDE SAFE ACCESS TO MACH RO... | $0 | $0 | Jan 17, 2002 |
| Apr 8, 1998 | 38072769Z | RESOLVE | Non-Hazardous | 39H73U 39-TRACTION SHEAVE WORN DOWN 73-HATCH CITY ID TAG CONTROLLER MACHINE & GENERATOR. | $180 | $0 | Jul 30, 1998 |
| Nov 26, 1996 | 34142839K | RESOLVE | Non-Hazardous | FAILURE TO FILE A REPORT OF COMPLIANCE WITH LOCAL LAW 16/84 CERTIFICATE TO THE INSTALLATION OF REQUIRED FIRE PROTECTI... | $500 | $0 | Jan 16, 1997 |
| Nov 9, 1994 | 34087274N | RESOLVE | Hazardous | WHILE USING A TWO POINT SUSPENSION SCAFFOLD . USE OF A TWO POINT "" WITHOUT PROPER DANGER SIGNS. FAILURE TO USE SAFET... | $0 | $0 | Apr 6, 1995 |
| Nov 9, 1994 | 34087275P | RESOLVE | Hazardous | WHILE USING A TWO POINT SUSPANSION NO PROPER DANGER SIGNS NOT USIING SAFTY BELTS NO RIGGERS LOCENCE USING 4 TWO POINT... | $5,000 | $0 | Jan 5, 1995 |