ECB violations
2 East 43 Street, Manhattan • Block 01277 • Lot 0069
34 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| May 1, 2025 | 39539735N | RESOLVE | CLASS - 2 | 18 STORY BUILDING UNDERGOING RENOVATION OBSERVED INSIDE ELEVATOR SHAFT SUPPORTED SCAFFOLD ERECTED 8 FRAMES ON ONE SID... | $0 | $0 | Nov 13, 2025 |
| May 1, 2025 | 39539736P | RESOLVE | CLASS - 2 | OBSERVED SUPPORTED SCAFFOLD INSIDE ELEVATOR SHAFT IMPROPERLY ASSEMBLED. SCAFFOLD LACKED REQUIRED TOE BOARDS AND GUARD... | $5,000 | $5,000 | Oct 26, 2026 |
| Jun 17, 2024 | 37028857Y | ACTIVE | CLASS - 2 | A. C. 27-929.1, FAILURE TO COMPLETE THE INSTALLATION OF A FULL SYSTEM OF AUTOMATIC SPRINKLERS AND FILE A FINAL SPRINK... | $6,280 | $0 | Apr 2, 2025 |
| Mar 19, 2024 | 35682451H | ACTIVE | CLASS - 1 | FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE AND APPURTENANCES. NOTE:-AT THE TIME OF INSPECTION OBSERVED AT EXP. #2 N... | $2,500 | $2,500 | Feb 4, 2025 |
| Jan 16, 2024 | 37026214L | RESOLVE | CLASS - 2 | FAILURE TO FILE ACCEPTABLE AMENDED CYCLE 8B AND 9B REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INI... | $1,250 | $1,250 | Apr 11, 2024 |
| Jul 15, 2023 | 39520352X | RESOLVE | CLASS - 1 | A WORKER INJURED WHEN FELL ON SCAFFOLD STEPS AND TAKEN TO OFF SITE MEDICAL FACILITY.PERMIT HOLDER JOB#123710216 FAILE... | $10,000 | $0 | Oct 10, 2024 |
| Jul 11, 2023 | 39519091Z | RESOLVE | CLASS - 1 | OBSERVED SUPPORTED SCAFFOLD PLATFORM HAS LOOSE PLANKS NOT TIEDOWN IN SOME AREAS IN CONTRARY WITH CODES 3314.5, ALSO L... | $2,500 | $0 | Sep 14, 2023 |
| Jul 11, 2023 | 39519090R | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN SUPPORTED SCAFFOLD GUARDRAILS IN CONTRARY WITH CODE 3314.8, MISSING SOME OPEN SIDES AND ENDS OF S... | $2,500 | $0 | Sep 14, 2023 |
| Feb 28, 2023 | 37025439H | ACTIVE | CLASS - 2 | A.C.27-929.1,FAILURE TO COMPLETE THE INSTALLATION OF A FULL SYSTEM OF AUTOMATIC SPRINKLERS AND FILE A FINAL SPRINKLER... | $6,280 | $0 | Dec 14, 2023 |
| Jul 21, 2022 | 35646596K | RESOLVE | CLASS - 1 | FAILURE TO NOTIFY DEPT OF INCIDENT THAT RESULTED IN FATALITY OR INJURYNOTE:WORKER FELL OFF SCF INJURED ARM&LEFT SIDE ... | $5,000 | $0 | Feb 2, 2023 |
| Jul 5, 2022 | 39503081Z | RESOLVE | CLASS - 2 | AT THE TIME OF MY FOLLOW UP INSPECTION OF A INCIDENT OCCURED ON 6/30/22 (EVLOEV ISLAM FALLED FROM BAKER SCAFFOLD) OBS... | $0 | $0 | Aug 25, 2022 |
| Jun 30, 2022 | 35581685H | RESOLVE | CLASS - 1 | BC 3301.1.1 RESPONSIBILITIES FOR SAFETY:FAILURE TO INSTITUTE ADEQUATE SAFETY MEASURES:OBSERVED ALTERATION WORK IN PRO... | $625 | $0 | Sep 29, 2022 |
| Mar 15, 2022 | 35642085K | RESOLVE | CLASS - 2 | PROJECT INFORMATION PANEL/SIDEWALK SHED PARAPET PANEL CONSTRUCTION SIGN NOT PROVIDED OR NOT IN COMPLIANCE WITH SECTIO... | $0 | $0 | Jun 16, 2022 |
| Mar 15, 2022 | 35642084Z | RESOLVE | CLASS - 2 | PROHIBITED SIGNS ON SIDEWALK SHED.AT TIME OF INSPECTION OF ACTIVE JOBSITE OBSERVED ADVERTISEMENT SIGN FOR NOM CONTRAC... | $0 | $0 | Jun 16, 2022 |
| Nov 6, 2021 | 35632324J | RESOLVE | CLASS - 1 | BC3314.1 SCAFFOLDS UTILIZED IN CONJUNCTION WITH CONSTRUCTION OF BUILDING SHALL BE ERECTED AND MAINATAINED SO SAFETY O... | $0 | $0 | Nov 3, 2022 |
| Nov 1, 2021 | 37022655Z | ACTIVE | CLASS - 2 | 27-929.1 FAILURE TO COMPLETE INSTALLATION OF FULL SYSTEM OF AUTOMATIC SPRINKLERS AND FILE FINAL SPRINKLER REPORT PREP... | $3,125 | $0 | Jul 21, 2022 |
| Oct 1, 2021 | 35505651P | RESOLVE | CLASS - 1 | 3310.3 FAILURE TO HAVE VALID SSP NOTE ATOI I OBSERVED FACADE RESTORATION IN PROCESS W/SSP123710216 NOT VALID�... | $2,500 | $0 | May 5, 2022 |
| Feb 24, 2021 | 35549901N | RESOLVE | CLASS - 2 | FAILURE TO PROVIDE APPROVED.ACCEPTED CONSTUCTION DOCUMENTS AT JOBSITE AT THE TIME OF MY INSPECTION AT THE TIME OF MY ... | $625 | $0 | May 13, 2021 |
| Feb 24, 2021 | 35549900L | RESOLVE | CLASS - 1 | WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND/OR APPROVED AMENDMENTS * AT THE TIME OF MY INSPECTION OF... | $2,500 | $0 | May 13, 2021 |
| Jul 13, 2020 | 37019856H | ACTIVE | CLASS - 2 | AC 27-929.1 FAILURE TO COMPLETE THE INSTALLATION OF A FULL YSTSEM OF AUTOMATIC SPRINKLERS AND FILE A FINAL SPRINKLER ... | $1,562 | $0 | Apr 29, 2021 |
| Nov 15, 2019 | 37016548M | ACTIVE | CLASS - 2 | 27-929.1 A.C. 27-929.1,FAILURE TO COMPLETE THE INSTALLATION OF A FULL SYSTEM OF AUTOMATIC SPRINKLERS AND FILE A FINAL... | $1,250 | $0 | Feb 20, 2020 |
| Nov 14, 2019 | 35460513K | RESOLVE | CLASS - 2 | POSTING OF UNLAWFUL SIGNS,INFORMATION,PICTORAL REPRESENTAITION,BUSINESS OR ADVERTITING MESSAGES ON PROTECTING STRUCTU... | $1,250 | $0 | Jan 23, 2020 |
| Aug 16, 2019 | 35448296L | RESOLVE | CLASS - 2 | WORK CONTRARY TO CONSTRUCTION DOCUMENTS-CD5. AT THE TIME OF MY INSPECTION,AT A 18 STY SS FACADE INSPECTION I OBSERVED... | $1,280 | $0 | Oct 17, 2019 |
| Aug 16, 2019 | 35448295J | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN/DISPLAY ON SITE DOCUMENTS REQUIRED BY CHPT 33. 18 STY OCCUPIED BLDG AT THE TIME OF MY INSPECTION,... | $6,250 | $0 | Oct 17, 2019 |
| Aug 1, 2018 | 37012179H | RESOLVE | CLASS - 2 | FAILURE TO FILE ACCEPTABLE AMENDED CYCLE 8B REPORT INDICATING CORRECT-ION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL F... | $1,250 | $0 | Mar 21, 2019 |
| Mar 20, 2018 | 35318606M | RESOLVE | CLASS - 1 | FAILURE TO TAKE REQUIRED MEASURES TO PROTECT PUBLIC FROM UNSAFE FACADEAS NOTED: ON 02/21/18 511 5TH AVENUE SUBMITTED ... | $10,000 | $0 | May 10, 2018 |
| May 3, 2017 | 35253769M | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN EXTERIOR BUILDING AND APPURTENANCES WEST ELEVATIONEXP1 LOOSE SOFFIT/CORNICE.CRACKED WATER TABLE B... | $500 | $0 | Jun 22, 2017 |
| Feb 26, 2016 | 35133970H | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG WALLS & APPURTENANCES. NOTED(1)AT EXP#3(BY NORTH EAST COURT YARD)(I) CRACKED MASONRY WAS FOU... | $500 | $0 | Apr 14, 2016 |
| Jul 2, 2014 | 38231838Z | RESOLVE | CLASS - 2 | 02L10,07B01,13L10,68B07,12Q07,02L10-ALARM SYSTEM DEFECTIVE REPAIR,07B01-ADJUST DOOR RESTIRCTOR NOT WORKING,13L10-REPA... | $0 | $0 | Aug 21, 2014 |
| May 14, 2008 | 34642248J | RESOLVE | Non-Hazardous | WORK W/O A PERMIT EXP PERMIT SHED ERECTED UNDER APPL 104453716 EXP 12/31/06 SHED STILL ERECTED AT TIME OF INSPECTION ... | $500 | $0 | Oct 2, 2008 |
| Aug 30, 2006 | 34527469J | RESOLVE | Non-Hazardous | FAILURE TO SAFEGUARD PUBLIC & PROPERTY AFFECTED BY CONST. OPERATIONS- IN THAT A BOLT HEAD AND WASHER FELL FROM FACADE... | $1,000 | $0 | Dec 14, 2006 |
| Mar 23, 1998 | 38072367X | RESOLVE | Non-Hazardous | 47B,47-SHORTEN GOVERNOR SAFETY CABLE. | $0 | $0 | Jul 9, 1998 |
| Mar 23, 1998 | 38072368H | RESOLVE | Non-Hazardous | 46L,47B,64B,#46-CHANGE HOIST ROPES #47-SHORTEN GOVERNOR SAFETY CABLES #64-SHORTEN COMPENSATING ROPES. | $350 | $0 | Jul 9, 1998 |
| Mar 23, 1998 | 38072366Y | RESOLVE | Non-Hazardous | 46B,64B,47B,46-SHORTEN HOIST ROPES 64-SHORTEN COMPENSATING ROPES-47 SHORTEN GOVERNOR SAFETY ROPES. | $350 | $0 | Jul 9, 1998 |