5 East 48 Street, Manhattan
Manhattan • Block 01284 • Lot 0006 • Zip: 10017
Condition
What the city currently has open against this building, counted from its own records.
Address
Land use and zoning
Building
Latest assessment
Neighborhood
The area this lot falls inside, and the commute Hoodkit measures from it.
Getting around
Estimated 4 days ago- Grand Central 9 min 4 walking, 5 riding
- Union Square 15 min 4 walking, 11 riding
- Times Square 16 min 4 walking, 12 riding
- Penn Station 22 min 4 walking, 18 riding
- Fulton Street 23 min 4 walking, 19 riding
- Downtown Brooklyn 31 min 4 walking, 27 riding
Around this address
Transit and places within 0.5 miles of the lot.
Getting out
Railroad
Ferry
Bus
Citi Bike
Places nearby
Grand Central Oyster Bar
Venerated, iconic eatery serving raw oysters, pan roasts & chowders in a bustling, vaulted setting.
Bar Chimera
No description yet
Le Bernardin
No description yet
Aquavit
No description yet
Cote 550
No description yet
Cuerno
No description yet
Din Tai Fung
Chinese restaurant
Double Knot
No description yet
Activity
Sales, filings, permits and violations from every dataset, in one order.
2023
-
DOB violation Jun 20, 2023
LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED
VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION
2021
-
CLASS - 2
ATOI FOUND GAS PILOT LINE TO BURNER HAD ALUMINUM TUBING, ALUMINUM ALLOY SHALL NOT BE USED ON GAS LINE, FGC403.4.4; MC...
2019
-
DOB violation Nov 8, 2019
LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2017 INSPECTION REPORT
2018
-
DOB violation Apr 6, 2018
LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2016 INSPECTION REPORT
2016
-
Alteration Type I
PROPOSING TWO (2) NEW DWELLING UNITS AT THE 3RD AND 4TH FLOORS. NEW CERTIFICATE OF OCCUPANCY REQUIRED
2014
-
DOB violation May 15, 2014
LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2012 INSPECTION REPORT
-
Alteration Type II
FACADE RESTORATION AND ROOF REPLACEMENT AS PER PLANS FILED HEREWITH. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
2013
-
Alteration Type III
NSTALLATION OF 39 LINEAR FEET OF HEAVY DUTY SIDEWALK SHED FOR REMEDIAL REPAIRS. SIDEWALK SHED SHALL COMPLY WITH 33/91...
-
Alteration Type III
INSTALLATION OF PIPE SCAFFOLD AS PER DRAWINGS. SCAFFOLD SHALL COMPLY WITH CHAPTER #33 OF THE 2008 CODE. NO CHANGE IN ...
-
DOB violation Mar 4, 2013
E-ELEVATOR ELEVATORREQUIRED
2011
-
DOB violation Jun 23, 2011
E-ELEVATOR ELEVATORREQUIRED
2008
-
Alteration Type III
INSTALL 25 FEET LONG, 55 FEET HIGH FRAME SCAFFOLD OVER SIDEWAK SHED TO FACILITATE WORKER ACCESS FOR FRONT FACADE AND ...
-
Alteration Type III
INSTALL 65 FEET LONG, 10 FEET HIGH HEAVY DUTY SIDEWAK SHED (300PSF) TO PROTECT PEDESTRIAN TRAFFIC DURING FRONT FACADE...
-
Non-Hazardous
38X10.58Y02.36X10.38X REPAIR TOP OF CAR INSPECTION 38Y CLEAN OIL OF MACHINE BRAKE DRUM 36X REPAIR LIGHT IN OVERHEAD
-
Non-Hazardous
16P16.34B10.53P16.54P16.55Y13.36M16.40M16.85B0736D06.16 PROVIDE ACCESSTO 3RD & 4TH FLS 34 REPAIR TOP CAR RUN BX (INSP...
2002
-
Non-Hazardous
50O02/57O02/74O02/22W06/33O02. 5002 REPLACE OIL SOAKED RAGS AND CLEAN MACHINE. 74002 PROPERLY CLEAN TOP OF CAR. 22W06...
The most recent 6 events from each dataset, so no one source takes the axis. Each tab holds the full record.
Property Contacts
Contact information aggregated from multiple government sources
Building Permits
Owner information from Department of Buildings filings
Recent Building Permits
Owner information from recent DOB NOW filings
Deed Records
Parties from ACRIS deed and mortgage records
Property Records
Owner information from assessment and PLUTO records