ECB violations
139 East 45 Street, Manhattan • Block 01300 • Lot 0025
17 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Jul 1, 2025 | 37036083J | ACTIVE | CLASS - 2 | FAILURE TO FILE REQUIRED ANNUAL BOILER INSPECTION REPORTS FOR LOW-PRESSURE BOILER 10000042531Y0001 IN ACCORDANCE WITH... | $625 | $0 | Jan 8, 2026 |
| Jul 7, 2004 | 34402167P | RESOLVE | Hazardous | USE OF RIGGING EQUIPMENT WIHTOUT PROPER DANGER SIGNS NO CERTIFICATE OFFITTNESS FOR THE SCAFFOLD WORKER REMEDY:WORKER ... | $5,000 | $0 | Sep 1, 2005 |
| Jan 4, 2001 | 34267531N | RESOLVE | Hazardous | FAILURE TO MAINTAIN BLDG.NOTED:APT 4B(LIVING ROOM)FLOOR HAS SEPARATION FROM WALL APPPROX 2"WIDE,WITH LENGTH OF APPROX... | $800 | $0 | Mar 15, 2001 |
| Dec 27, 1999 | 34234786Y | RESOLVE | Non-Hazardous | FAILURE TO PROVIDE EQUIPMENT. USE PERMITS. NOTED INSTALLATION OF MECHANICAL EQUIPMENT WITHOUT FIRST OBTAINING AN EQUI... | $300 | $0 | Feb 10, 2000 |
| May 28, 1997 | 34149022H | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN EXTERIOR BUILDING WALL. DEFECT IS: WEST SIDE BRICK PARAPET WALL ON ROOF LEANING INWOOD TOWARD REA... | $1,000 | $0 | Nov 6, 1997 |
| May 23, 1996 | 34137503K | RESOLVE | Non-Hazardous | WORK WITHOUT PERMIT. ELECTRICAL INSTALLATION WAS OCCURING AT APARTMENT4A AND 3A AT TIME OF INSPECTION. DEPARTMENT REC... | $0 | $0 | Aug 15, 1996 |
| May 23, 1996 | 34137501R | RESOLVE | Non-Hazardous | WORK WITHOUT PERMIT REFURVISHING OF INTERIOR PARTITONS AT APARTMETN 3A AND 4A IN THAT NEW FRAMED WALL IN BATHROOMS AN... | $0 | $0 | Aug 15, 1996 |
| May 23, 1996 | 34137502Z | RESOLVE | Non-Hazardous | WORK WITHOUT PERMIT:NEW WASTE + SUPPLIES LINES WERE INSTALLED AT BATH ROOMS + KITCHEN OF APT 3A + 4A A SEARCH OF DEPT... | $0 | $0 | Aug 15, 1996 |
| Apr 9, 1996 | 34135236X | RESOLVE | Non-Hazardous | WORK WITHOUT A PERMIT WORK NOTED: WOOD TYPE STRUCTURE APPROX 7' HIGH CONSTRUCTED THROUGHOUT APT 2A AND USE FOR STORAG... | $0 | $0 | Aug 22, 1996 |
| Mar 6, 1996 | 34134188X | RESOLVE | Non-Hazardous | WORK WITHOUT PERMIT(PLUMBING)THE FOLLOWING WORK WAS NOTED:APT 2B SUPP-LY LINES AND FIXTURES WERE REMOVED IN PREPERATI... | $0 | $0 | Jul 25, 1996 |
| Mar 6, 1996 | 34134322H | RESOLVE | Non-Hazardous | WORK WITHOUT PERMIT.REMOVED ELECTRICAL WIRING AND FIXTURES AT APT 2B AND INSTALLED NOW ELECTRICAL FIXTURES AND WIRE A... | $0 | $0 | May 30, 1996 |
| Mar 6, 1996 | 34134321X | RESOLVE | Non-Hazardous | WORK WITHOUT PERMIT-AN ALTERATION OCCURING AT APT 2B TO 3A AT TIME OF INSPECTION.APT 2B HAD CEILING REMOVED AND PREPE... | $0 | $0 | May 30, 1996 |
| Aug 8, 1995 | 34128662N | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN EXTERIOR BUILDING WALL. DEFECT IS: CHIMNEY IS OUT OF PLUMB APPROX. 5, LEANING IN WARD. LOCATION: ... | $0 | $0 | Dec 7, 1995 |
| Apr 27, 1995 | 34124209R | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN DEFECT ARE 1-ROOF LADDER INTERIOR AS LOOSE FROM WALL.2-PARAPET WALL IS OUT OF PLUM & LEANING INTO... | $0 | $0 | Jul 20, 1995 |
| Apr 17, 1995 | 34124208P | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN DEFECT ARE 1-HALL LANDING AT 2,3,&4 FLOOR OUT OF PLUM.2-WINDOWS SILL BROKEN,ROTTEN & DEFECTS 3-BA... | $0 | $0 | Jul 20, 1995 |
| May 19, 1993 | 34091837J | RESOLVE | Non-Hazardous | OPERATION OF A PLACE OF ASSEMBLY WITHOUT A VALID PERMIT 2 STORY RESTAURANT TOTAL CAPACITY 99 CUSTOMERS & APPROX 10 EM... | $0 | $0 | Jul 22, 1993 |
| Apr 9, 1993 | 34135237H | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN EXTERIOR BUILDING WALL DEFECT NOTED: PARAPET WALL LEANNING INWARD AT NORTHWEST WALL. REMEDY: FILE... | $0 | $0 | Aug 22, 1996 |