Issued Violation Status Severity Description Penalty Balance due Hearing
Dec 1, 2025 39547540N RESOLVE CLASS - 1 OBSERVED PIPE SCAFFOLD INSTALLED ON SWS @ EXPO 1,2,4, NOT MAINTAINED AS PER BC 3314.1. OBSERVED MULTIPLE AREAS W/ PLA... $5,000 $5,000 Aug 27, 2026
Dec 1, 2025 39547544K RESOLVE CLASS - 2 OBSERVED ACTIVE JOBSITE WITH STREET ENCLOSURE @ EXPO #1 WITH EXPIRED DOT PERMIT ON 11/27/2025. ACTIVE DOT PERMIT REQU... $2,500 $2,500 Aug 27, 2026
Dec 1, 2025 39547541P RESOLVE CLASS - 1 OBSERVD BALCONIES, WINDOWS & TERRACE ON FLRS 17, 15 & 11 W/OUT ADEQUATE FALL PROTECTION OR CAZ IN PLACE. DOORS TO BAL... $5,000 $0 Feb 5, 2026
Dec 1, 2025 39547543Z RESOLVE CLASS - 2 OBSERVED SWS @ EXPO#4 W/ PROHIBITED ILLUMINATED SIGN AND BUSINESS ADVERTISING MESSAGE INSTALLED ON SWS PARAPET. REVIE... $2,500 $0 Feb 5, 2026
Dec 1, 2025 39547542R RESOLVE CLASS - 2 OBSERVED 19 STORY BUILDING W/ EXCESSIVE AMOUNTS OF CONSTRUCTION DEBRIS ACCUMULATED ON MULTIPLE FLOORS. DEBRIS PLACED ... $0 $0 Feb 5, 2026
Dec 1, 2025 39547500Z RESOLVE CLASS - 1 OBSERVED SIDEWALK SHED INSTALLED @ EXPO #1,2,4 W/ HEIGHT, SPANS, CROSS BRACING, EXTENSIONS, ILLUMINATED SIGN ON PARAP... $2,500 $2,500 Aug 27, 2026
Sep 2, 2025 39544362X RESOLVE CLASS - 1 BC 3314.1 AT TIME OF INSPECTION OBSERVED SUPPORTED SCAFFOLD NOT MAINTAINED AS PER CODE. SUPPORTED SCAFFOLD AT EXP# 1,... $5,000 $5,000 Jul 23, 2026
Sep 2, 2025 39544363H RESOLVE CLASS - 2 AT THE TIME OF MY INSPECTION OF A 19-STORY NEW BUILDING ACTIVE JOB SITE, I OBSERVED WORKERS PERFORMING STYROFOAM AND ... $1,250 -$3,750 Jul 23, 2026
Sep 2, 2025 39544364J RESOLVE CLASS - 1 3308.7 AT THE TIME OF MY INSPECTION OF A 19-STORY BUILDING, I OBSERVED AN OPEN AREA AT THE 18TH-FLOOR BALCONY WITH NO... $5,000 $0 Jul 23, 2026
Jul 21, 2025 39542619N RESOLVE CLASS - 1 RESPONDING TO AN INCIDENT WHERE A WORKER GOT HIT ON HIS RIGHT LEG WITH AN OSHA PLANK WHILE ANOTHER WORKER ABOVE HIM W... $5,000 $5,000 Oct 15, 2026
Jul 21, 2025 39542618L RESOLVE CLASS - 1 RESPONDING TO AN INCIDENT WHERE A WORKER GOT HIT ON HIS RIGHT LEG WITH AN OSHA PLANK WHILE ANOTHER WORKER ABOVE HIM W... $5,030 $5,030 Feb 18, 2027
Jul 21, 2025 39542617J RESOLVE CLASS - 1 RESPONDING TO AN INCIDENT WHERE A WORKER GOT HIT ON HIS RIGHT LEG WITH AN OSHA PLANK WHILE ANOTHER WORKER ABOVE HIM W... $2,530 $2,530 Feb 18, 2027
Apr 16, 2025 39539188N RESOLVE CLASS - 2 OBSERVED EQUIPMENT STORED AT THE 11TH FLOOR WITH INADEQUATE SAFETY MEASURES TO PROTECT SITE WORKERS FROM FALLING HAZA... $0 $0 Jan 8, 2026
Jan 14, 2025 39535933X RESOLVE CLASS - 2 BC 3307.1 RESPONSE TO FOLLOW UP OF AN INCIDENT OCCURRED ON 01-13-2024 IN THE AFTERNOON WHERE A PEDESTRIAN FELL ON THE... $0 $0 Mar 5, 2026
Aug 20, 2024 35684056R RESOLVE CLASS - 2 WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND/OR APPROVED AMENDMENTS. AS NOTED: AT TIME OF INSPECION O... $0 $0 Oct 31, 2024
Aug 20, 2024 35684057Z RESOLVE CLASS - 2 FAILURE TO MAINTAIN/DISPLAY ONSITE DOCUMENTS REQUIRED BY CHAPTER 33. AS NOTED AT TIME OF INSPECTION ON AN ACTIVE CONS... $1,250 $0 Oct 31, 2024
Aug 7, 2024 39531185L RESOLVE CLASS - 1 AT TIME OF INSPECTION RESPOND TO AN COMPLAIN OF CONRETE FALLING ON THE ADJACENT PROPERTY AT 127 EAST 55 ST STREET BAL... $0 $0 Jan 27, 2025
Aug 7, 2024 39536775Y RESOLVE CLASS - 1 AT TIME OF INSPECTION RESPOND TO AN COMPLAINT OF CONCRETE FALLING ON THE ADJACENT PROPERTY AT 127 EAST 55 ST BALCONY ... $0 $0 Aug 14, 2025
Aug 7, 2024 39531191H ACTIVE CLASS - 1 1 RCNY 3310-02 (E) 4AT TIME OF INSPECTION RESPOND TO AN COMPLAIN OF CONCRETE FALLING ON THE ADJACENT PROPERTY AT 127 ... $12,500 $12,500 Feb 16, 2027
Aug 7, 2024 39531189Z RESOLVE CLASS - 1 AT TIME OF INSPECTION RESPOND TO AN COMPLAIN OF CONRETE FALLING ON THE ADJACENT PROPERTY AT 127 EAST 55 ST STREET BAL... $0 $0 Jun 11, 2026
Aug 7, 2024 39531177L RESOLVE CLASS - 1 AT TIME OF INSPECTION RESPOND TO AN COMPLAIN OF CONRETE FALLING ON THE ADJACENT PROPERTY AT 127 EAST 55 ST STREET BAL... $5,000 $0 Jun 11, 2026
Jun 5, 2024 39529318N RESOLVE CLASS - 1 AN INCIDENT THAT OCCURRED ON 04-10-2024 AT THIS JOBSITE WHERE A WORKER INJURED HIS FINGER DURING CONSTRUCTION OPERATI... $0 $0 Aug 15, 2024
May 15, 2024 35681662N RESOLVE CLASS - 1 FAILURE TO OBTAIN REGISTERED DESIGN PROFESSIONAL EVALUATION PRIOR TO USING EXISTING STRUCTURE TO SUPPORT FORMWORK LOA... $5,000 $0 Jul 25, 2024
May 10, 2024 39528506X RESOLVE CLASS - 2 3301.8.2 TAMPERING PROHIBITED RESPOND TO AN INCIDENT WHERE A WORKER WAS INSTALLING A WOODED PORT STOP FOR THE CONCRET... $0 $0 Jul 18, 2024
May 10, 2024 39528505Y RESOLVE CLASS - 2 RESPOND TO AN INCIDENT WHERE A WORKER WAS INSTALLING A WOODED PORT STOP FOR THE CONCRETE BEAM WHEN WORKER FELL FROM T... $0 $0 Jul 18, 2024
Apr 11, 2024 39527471K RESOLVE CLASS - 1 AT TIME OF INSPECTION IN RESPONSE TO AN INCIDENT THAT OCCURRED ON 4-10-2024 BY 3 PM WHERE A WORKER INJURED HIS FINGER... $0 $0 Jun 5, 2025
Apr 11, 2024 39527472M RESOLVE CLASS - 2 AT TIME OF INSPECTON I OBSERVED SIDEWALK SHED INSTALLED ON EXPOSURE # 1 AND 2 WITHOUT SIGNS OR PROJECT INFORMATION PA... $1,250 $0 Jun 5, 2025
Aug 26, 2021 38274063M ACTIVE CLASS - 1 97X10: (97-X-10) ELEVATOR OUT OF SERVICE/REPAIR $1,250 $0 Nov 18, 2021
May 21, 2021 37021034L RESOLVE CLASS - 2 FAILURE TO COMPLY W/COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATION #35432464P ISSUED ON 12/23/2019,& TO FILE A C... $3,125 -$3,125 Dec 30, 2021
Mar 6, 2020 39019120H ACTIVE CLASS - 1 RESTORE TO SERVICE CLASS 1 CONTINUED. $6,250 $0 Feb 11, 2021
Dec 23, 2019 35432464P ACTIVE CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER AT THE TIME FO INSEPCTION OBSERVED BROKEN TILES TO TEH STAIRCAS... $625 $0 Feb 27, 2020
Nov 4, 2019 39012295H ACTIVE CLASS - 1 97/X/17 RESTORE TO SERVICE FOR PROPER INSPECTION BY DOB $1,250 $0 Oct 8, 2020
Sep 12, 2019 39009436P ACTIVE CLASS - 1 AS PER ONE, GAS FIRED, BURNHAM PF-505 IN CELLAR OF 660 LEX. AVE. ; PROHIBITED FLUE MATERIAL-NO FRESH AIR TO BOILER RO... $1,250 $0 Oct 31, 2019
Oct 27, 1999 34227689R RESOLVE Non-Hazardous INSTALLATION OF MECHANICAL EQUIPMENT WITHOOUT FIRST OBTAINING AN EQUIPMENT USE PERMIT. NOTED THERE ARE 5 A/C UNITS ON... $0 $0 Mar 30, 2000
Nov 21, 1997 38065501M RESOLVE Non-Hazardous 57O,36W,36T,43Y,73O,14P,75U, 73-CLEAN ENTIRE DEVICE 57-CLEAN PIT 43-REPAIR AND CLEAN 75-TEST AND TAG $0 $0 Apr 9, 1998
Oct 31, 1997 34160832R ACTIVE Non-Hazardous FAILURE TO PROVIDE ELEVATOR SIGN AT ELEVATOR BANK ON 2ND FLOOR AND BASEMENT. FAILURE TO PROVIDE 3" HIGH ALPHABETIC LE... $600 $0 Jan 15, 1998
Oct 31, 1997 34160831P ACTIVE Non-Hazardous FAILURE TO FILE A REPORT OF COMPLIANCE WITH LOCAL LAW 16/84, CERTIFYING OT THE INSTALLATION OF REQUIRED FIRE PROTECTI... $400 $0 Jan 15, 1998
Mar 2, 1994 38037623M ACTIVE Non-Hazardous 73X RISTOR PASS ELEVATOR CITY #27897 TO PROPER SERVICE. $1,000 $0 Apr 28, 1994
Aug 10, 1988 34010399L ACTIVE Hazardous FAILURE TO MAINTAIN. REMEDY: MAKE ALL NECESSARY REPAIRS TO THE SATISFACTION OF THIS DEPARTMENT. $1,000 $0 Nov 17, 1988