ECB violations
228-238 East 44 Street, Manhattan • Block 01317 • Lot 0030
62 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Jun 3, 2026 | 39191111K | ACTIVE | CLASS - 1 | VF.... CEASE USED.. DOOR RESTRICTOR NOT WORKING 5-A-10... WHEN THE CAR IS OUT SIDE THE UNLOCKING ZONE THE CAR DOOR SH... | $1,250 | $1,250 | Aug 13, 2026 |
| Feb 9, 2026 | 39176538Y | RESOLVE | CLASS - 1 | 5/L/10 CLASS 1, CAR CEASE USE CAR DOOR RESTRICTOR DEFECTIVE REPAIR 2/X/10 OUT SIDE COMM INOPERATIVE REPAIR. | $1,250 | $1,250 | Jun 4, 2026 |
| Apr 29, 2025 | 39146453H | RESOLVE | CLASS - 2 | CLASS 2: ELEVATOR OUT OF SERVICE,OBTAIN CERTIFICATE OF COMPLIANCE FOR APPLICATION MO8026370 FOR MODERNIZATION OF DEVI... | $0 | $0 | Jul 3, 2025 |
| Sep 18, 2024 | 39125257H | ACTIVE | CLASS - 1 | CLASS 1. DOOR ZONE RESTRICTOR NOT WORKING PROPERLY. THIS SAFETY DEVICE PREVENTS THE CAB DOOR FROM OPENING IN BETWEEN ... | $1,250 | $0 | Jan 2, 2025 |
| May 16, 2022 | 39062265M | RESOLVE | CLASS - 1 | V/F CLASS 1, 97/X/17 RESTORE TO SERVICE FOR PROPER INSPECTION BY DOB | $0 | $0 | Feb 23, 2023 |
| Mar 14, 2022 | 39058071M | RESOLVE | CLASS - 1 | OUT OF SERVICE | $1,250 | $0 | Sep 19, 2022 |
| Mar 1, 2022 | 35634696J | RESOLVE | CLASS - 2 | FAILURE TO COMPLY WITH COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPARTMENT OF BUILDINGS FOR ... | $1,250 | $0 | Sep 15, 2022 |
| Mar 1, 2022 | 35634699P | RESOLVE | CLASS - 2 | FAILURE TO COMPLY WITH COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPARTMENT OF BUILDINGS FOR ... | $625 | $0 | Sep 15, 2022 |
| Mar 1, 2022 | 35634800K | RESOLVE | CLASS - 2 | FAILURE TO COMPLY WITH COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPARTMENT OF BUILDINGS FOR ... | $625 | $0 | Sep 15, 2022 |
| Mar 1, 2022 | 35634693Y | RESOLVE | CLASS - 2 | FAILURE TO COMPLY WITH COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPARTMENT OF BUILDINGS FOR ... | $1,250 | $0 | Mar 2, 2023 |
| Mar 1, 2022 | 35634697L | RESOLVE | CLASS - 2 | FAILURE TO COMPLY WITH COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPARTMENT OF BUILDINGS FOR ... | $1,250 | $0 | Mar 2, 2023 |
| Mar 1, 2022 | 35634694X | RESOLVE | CLASS - 2 | FAILURE TO COMPLY WITH COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPARTMENT OF BUILDINGS FOR ... | $1,250 | $0 | Sep 15, 2022 |
| Mar 1, 2022 | 35634695H | RESOLVE | CLASS - 2 | FAILURE TO COMPLY WITH COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPARTMENT OF BUILDINGS FOR ... | $1,250 | $0 | Sep 15, 2022 |
| Mar 1, 2022 | 35634698N | RESOLVE | CLASS - 2 | FAILURE TO COMPLY WITH COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPARTMENT OF BUILDINGS FOR ... | $625 | $0 | Sep 15, 2022 |
| Oct 12, 2021 | 35592283Z | RESOLVE | CLASS - 1 | BC907.28 FAILURE TO PROVIDE FIRE ALARM SYSTEM FOR TRANSIENT USE FOR APT 10H,85,7G,4H,4D,4A,4B,4C,5A.PREVIOUS VIOLATIO... | $2,500 | $0 | Aug 4, 2022 |
| Oct 12, 2021 | 35592282R | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.LACK OF SYSTEM OF AUTOMATIC SPRINKLER WHERE IS REQUIRED AS PER ... | $1,250 | $0 | Aug 4, 2022 |
| Oct 12, 2021 | 35592284K | ACTIVE | CLASS - 1 | ALTERED/CHANGED BUILDING OCCUPIED WITHOUT VALID C OF O AS PER 28-118.3, 28-H3.2 NOTED 121839787 EXPIRED 1/8/2015.PREV... | $6,250 | $0 | Sep 14, 2022 |
| Oct 12, 2021 | 35592280N | RESOLVE | CLASS - 1 | PERMANENT DWELLING USED/CONVERTED FOR OTHER THAN PERMENANT RESIDENTIAL PURPOSES C OF O #121830787 INDICATES PREMISES ... | $15,000 | $0 | Aug 4, 2022 |
| Aug 12, 2021 | 35587305Y | RESOLVE | CLASS - 1 | PERMANENT DWELLING USED/CONVERTED FOR OTHER THAN PERMANENT RESIDENT PURPOSES C/O121830787 INDICATES DWELLING BE LEGAL... | $6,000 | $0 | Jun 23, 2022 |
| Aug 12, 2021 | 35587308J | RESOLVE | CLASS - 1 | BC097.2.8 FAILURE TO PROVIDE FIRE ALARM SYSTEM FOR TRANSIENTS USE IN APT10B 10H 4A 4B PREV V35510755X ISSUED6/1/21 DI... | $2,500 | $0 | Jun 23, 2022 |
| Aug 12, 2021 | 35587309L | ACTIVE | CLASS - 1 | ALT/CHANGE BLDG OCCUPIED W/O VALID C/O AS PER28-118.3.1,28-118.3.2 NOTED ATOI C/O121830787 EXPIRED1/18/18 PREV V35510... | $2,500 | $0 | Sep 14, 2022 |
| Aug 12, 2021 | 35587307H | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BLDG IN CODECOMPLIANT MANNER LACK OF SYSTEM OF AUTOMATIC SPRINKLER WHERE REQUIRED AS PER BC903.2&... | $1,250 | $0 | Jun 23, 2022 |
| Jun 1, 2021 | 35510757J | RESOLVE | CLASS - 2 | ALTERED/CHANGE BUILDING OCCUPIED WITHOUT A VALID COFO OF OCCUPANCY AS PER 28-118.3,28-1183.2 NOTED 121830787 EXPIRED ... | $0 | $0 | Jan 6, 2022 |
| Jun 1, 2021 | 35510753M | RESOLVE | CLASS - 1 | PERMANENT DWELLING USED/CONVERTED FOR OTHER THAN PERMANENT RESIDENTIALPURPOSES BY COFO 121830787 INDICATES PERMISES T... | $0 | $0 | Jan 6, 2022 |
| Jun 1, 2021 | 35510754Y | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER LACK OF A SYSTEMOF AUTOMATIC SPRINKLER WHERE IS REQUIRED AS PER... | $0 | $0 | Jan 6, 2022 |
| Jun 1, 2021 | 35510755X | RESOLVE | CLASS - 1 | BC 907.2.8 FAILURE TO PROVIDE FIRE ALARM SYSTEM FOR TRANSIENT USE AT APT#8J,5A,4A,4D, AND 4H.REM:DISCONTINUE ILLEGAL ... | $0 | $0 | Jan 6, 2022 |
| Apr 29, 2021 | 38273459Y | RESOLVE | CLASS - 2 | 2X10,68B7 2X10 PHONE INOPERATIVE 68B7 LOG BOOK NOT UP TO DATE | $0 | $0 | Jul 15, 2021 |
| Jan 19, 2021 | 39035031X | RESOLVE | CLASS - 2 | PHONE IN CAR INOPERATIVE. REPAIR. IMPROPER FUESE IN CONTROLLER. REPLACE. MAINTENANCE LOG BOOK MISSING. PROVIDE. BRAKE... | $0 | $0 | Aug 19, 2021 |
| Jan 19, 2021 | 39035030Y | RESOLVE | CLASS - 2 | PHONE IN CAR INOPERATIVE. REPAIR. LEBEL OF FUSES UNREADABLE. REPLACE. BRAKE TAG IN MACHINE ROOM MISSING. PROVIDE. MAI... | $0 | $0 | Aug 19, 2021 |
| Jul 10, 2020 | 35474393M | ACTIVE | CLASS - 2 | FAILURE TO PROVIDE APPROVED/ACCEPTED CONST DOCUMENTS @JOB SITE @TIME OF INSPECTION NOTE: @TIME OF INSPECITON I ASKED ... | $3,125 | $0 | Sep 17, 2020 |
| May 1, 2020 | 35487107P | ACTIVE | CLASS - 2 | ONGOING CONSTRUCTION ACTIVITIES CONTRARY TO GOVERNOR'S EXECUTIVE ORDER#202.6,202.8,202.11202.13 & GUIDANCE PUBLISHED ... | $5,000 | $0 | Apr 29, 2021 |
| Jan 7, 2019 | 38266133Z | RESOLVE | CLASS - 1 | CU26M7,26X10; 59E1,42G7,60L10,61T7,42B6. 26M7-PROVIDE ESCAPE HATCH COVER; 26M7-REPAIR ESCAPE HATCH SWITCH TO FUNCTION... | $1,250 | $0 | Feb 28, 2019 |
| Aug 28, 2018 | 38265000K | RESOLVE | CLASS - 1 | 97X17 RESTORE TO SERVICE IMMEDIATELY AS PER CODE AND CONTACT NYCDOB THAT DEVICE HAS BEEN RESTORED TO SERVICE. | $1,250 | $0 | Dec 20, 2018 |
| Feb 2, 2018 | 38255615H | RESOLVE | CLASS - 2 | 2L10,401009; COMM IN CAR NOT WORKING REMOVE PIPE FROM FLOOR CLEAN MOTOR ROOM. | $0 | $0 | May 24, 2018 |
| Feb 2, 2018 | 38255614X | RESOLVE | CLASS - 2 | 2L10,40100-9,23X10. 2L10 (COMM) 40-400-0 REMOVE PIPE FROM FLOOR;REMOVE OIL FROM M/R BSEMENT, NMOT WORKING ON BASEMENT... | $0 | $0 | May 24, 2018 |
| Mar 8, 2016 | 38240316X | RESOLVE | CLASS - 1 | 97## ELEVATOR BEING USED FOR CONSTRUCTION USE W/O CONSTRUCTION USE PERMIT. | $800 | $0 | Jun 16, 2016 |
| Nov 3, 2010 | 34879249R | RESOLVE | CLASS - 2 | WORK W/O PERMIT.WORK NOTED:@ TIME OF INSPECTION IN APT#4H,FULL HEIGHT PARTITIONS WERE ERECTED CREATING A 2ND BEDROOM.... | $0 | $0 | May 13, 2011 |
| Sep 9, 2010 | 34838991K | RESOLVE | CLASS - 2 | WORK W/O PERMIT. WORK NOTED: IN APT 2J ERECT FULL HEIGHT PARTITIONS TO CREATE 2ND BEDROOM & WALL BETWEEN BATHROOM & L... | $800 | $0 | Jul 28, 2011 |
| Sep 9, 2010 | 34838992M | RESOLVE | CLASS - 1 | FAILURE TO COMPLY WITH DIRECTION OF SWING. NOTED: AT GROUND FL STAIR CASE'C' DOOR SWING AGAINST DIRECTION OF EGRESS T... | $800 | $0 | Jul 28, 2011 |
| Jan 28, 2009 | 38201341X | RESOLVE | CLASS - 2 | 97X# 97X# FOUND DEVICE INOPERATIVE RESTORE DEVICE BACK TO SERVICE | $250 | $0 | Apr 30, 2009 |
| Jan 28, 2009 | 38200415P | RESOLVE | CLASS - 2 | 97X# 97X FOUND ENTIRE DEVICE INOPERATIVE RESTORE DEVICE BACK TO SERVICE | $0 | $0 | Mar 19, 2009 |
| Aug 8, 2008 | 34689497Z | RESOLVE | CLASS - 3 | WORK W/O A PERMIT. NOTED: AT 5TH FLR IN APT DESIGNATED AS 5J 2 FULL HEIGHT PARTITIONS ERECTED: EACH PARTITION APPROX ... | $0 | $0 | Sep 25, 2008 |
| Apr 3, 2008 | 38182816J | RESOLVE | Non-Hazardous | 28B01,65B11:28B01-DOOR CLOSES TOO FAST.TOO HARD. 65B11-PROVIDE PIT STOP SWITCH TP CODE 210.3E1-4 | $350 | $0 | May 29, 2008 |
| Apr 3, 2008 | 38182815H | RESOLVE | Non-Hazardous | 55Y13,28B01,64X10,66O02,38X10,65B11:55Y13-EXCESSIVE MACHINE LEAKING ONTO CAB IN SHAFT,28B01-DOOR OPERAOR CLOSIGNSPEED... | $350 | $0 | May 29, 2008 |
| Jan 16, 2008 | 34618405Y | RESOLVE | Non-Hazardous | WORK W/O PERMIT WORK NOTED:INTERNAL PARTITIONS HAVE BEEN ERECTED IN APT # 3E (3RD FL) 10K (10 FL) & 14F (13 FL) TO CO... | $500 | $0 | Mar 13, 2008 |
| Oct 11, 2007 | 34607076Z | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN BLDG. DEFECTS NOTED: CONCRETE CEILING IS SPALLING LEAVING EXPOSED REBARS ON THE CELLAR LEVEL. REM... | $180 | $0 | Jan 10, 2008 |
| Apr 13, 2004 | 34432635Y | RESOLVE | Non-Hazardous | WORK WITHOUT A PERMIT NOTED AT THE BACK OF THE PARKING GARAGE AT 230 E44ST AN APPROX 10'X 20'ENCLOSURE WALLS WERE CON... | $0 | $0 | Nov 18, 2004 |
| Nov 26, 2002 | 34372629X | RESOLVE | Non-Hazardous | WORK WITHOUT A PERMIT. WORK NOTED: IN CELLAR AT REAR OF PARKING GARAGE ERECTED PARTITION WALLS WITH WINDOW AND DOUBLE... | $500 | $0 | Jan 16, 2003 |
| Nov 26, 2002 | 34372628Y | RESOLVE | Non-Hazardous | OCCUPANCY CONTRARY TO THAT ALLOWED BY THE CERT. OF OCCUPANCY # 58573. ILLEGAL OCCUPANCY NOTED : AT CELLAR LEVEL, AT R... | $800 | $0 | Jan 30, 2003 |
| Jan 16, 1998 | 38068965Y | RESOLVE | Non-Hazardous | 74M,75U,35B, 74M-PROVIDE CITY I.D TAGS ON ALL MOTOR ROOM MACHINE AND EQUIPMENT 75U-PROVIDE CURRENT 5 YEAR TAG OR PERF... | $180 | $0 | Jun 11, 1998 |